الوصف
Product Description
The KL3104X1-BA1 is an intrinsically safe (I.S.) discrete output CHARM module from Emerson, designed for DeltaV systems. It provides up to 45 mA digital output signals, enabling safe control of actuators, solenoids, and other low-power field devices in hazardous areas.
Engineered for Zone 2 / Class I Division 2 environments, this module offers compact CHARM integration, robust environmental resistance, and reliable operation under vibration, shock, and airborne contaminant exposure. The keyed 3E terminal block ensures proper installation and wiring security. With no user-serviceable parts and no calibration required, KL3104X1-BA1 delivers maintenance-free, dependable performance.
Technical Specifications
-
Model: KL3104X1-BA1
-
Module Type: Intrinsically Safe Discrete Output (DO) CHARM
-
Output Signal: Digital, up to 45 mA
-
Safety Type: Intrinsically Safe (I.S.)
-
CHARM Bus Power: +6.3 VDC, 0 mA
-
Field Circuit Power: +24 VDC, 78 mA
-
Channels: Single-channel output
-
Terminal Block Key Position: 3E
-
Operating Temperature: –40 °C to +70 °C
-
Humidity: 5–95% RH, non-condensing
-
Shock Resistance: 10 g, half-sine wave, 11 ms
-
Vibration: 2–13.2 Hz: 1 mm peak-to-peak; 13.2–150 Hz: 0.7 g
-
Airborne Contaminants: ISA-S71.04-1985 Class G3
-
Weight: 0.51 lbs
Safety & Compliance
-
Hazardous Atmosphere Ratings:
-
II 3(1) G Ex ec [ia Ga] IIC Gc
-
II 3G (1D) Ex ec [ia IIIC Da] IIC Gc
-
Class I, Division 2, Groups A–D
-
Zone 2 AEx ec [ia Ga/IIIC Da] IIC Gc
-
Certifications: ATEX, IECEx, FM, UKEX
-
Installation Note: Must not be inserted or removed while energized unless the area is confirmed non-hazardous
Key Highlights
-
Provides intrinsically safe discrete output for hazardous areas
-
Supports low-power devices with up to 45 mA drive capability
-
Compact CHARM form factor allows seamless DeltaV system integration
-
Wide environmental tolerance: –40 °C to +70 °C, Class G3 airborne contaminants
-
Keyed terminal block ensures correct installation and wiring
Applications
-
Driving actuators, solenoids, and field indicators in hazardous environments
-
DeltaV systems requiring single-channel intrinsically safe outputs
-
Oil, gas, and chemical plants with Zone 2 / Class I Div. 2 installations
FAQ
Q: Can this module be used in Zone 2 hazardous areas?
A: Yes, the KL3104X1-BA1 is intrinsically safe and certified for Zone 2 / Class I Division 2.
Q: What is the maximum output current?
A: The module supports discrete output signals up to 45 mA per channel.
Q: Is calibration required?
A: No, the module requires no calibration and has no user-serviceable parts.
الميزات
نحن نرحب بالطلبات الكبيرة ولدينا حد أدنى للطلب يبلغ وحدة واحدة فقط.
عند الطلب، يمكننا توفير جميع الوثائق اللازمة، بما في ذلك شهادات المنشأ/المطابقة وغيرها من مستندات التصدير المطلوبة.
بالنسبة للعناصر المتوفرة في المخزون، نهدف إلى التسليم خلال 1-3 أيام بعد تأكيد الدفع. سيتم تسليم العناصر التي لها أوقات انتظار محددة وفقًا للجدول المقتبس.
نحن نقبل الدفع بنسبة 100% عن طريق التحويل البرقي (T/T) قبل الشحن. بالنسبة للعناصر التي لها أوقات انتظار، يتطلب دفع 30% كدفعة مقدمة، مع دفع الـ 70% المتبقية قبل الشحن. بالنسبة لتحويلات اليوان الصيني (RMB)، يرجى الاتصال بنا إذا كان لديك وكيل في الصين.
نحن نقدم ضمانًا قياسيًا لمدة سنة واحدة على جميع العناصر الجديدة والأصلية. إذا كنت بحاجة إلى ضمان ممتد، يرجى الاتصال بنا للحصول على تفاصيل التكلفة الإضافية.
رضاكم مهم بالنسبة لنا. إذا كنت بحاجة إلى إرجاع عنصر، يجب أن يتم ذلك خلال 30 يومًا من تاريخ الطلب. يجب أن يكون المنتج غير مستخدم، غير مفتوح، وفي عبوته الأصلية مع جميع الملحقات المرفقة. تتم معالجة المبالغ المستردة خلال 5-7 أيام عمل بعد استلامنا للعنصر المُعاد. يرجى ملاحظة أن رسوم الشحن والرسوم ذات الصلة غير قابلة للاسترداد.