الوصف
Product Description
The KL3106X1-LS1 from Emerson is a single-channel analog input CHARM module engineered for thermocouple signals in DeltaV systems. Its intrinsically safe (I.S.) design ensures secure operation in hazardous environments, including Zone 2 and Class I Division 2 locations.
Featuring LS1 keyed terminals, this module prevents miswiring and simplifies installation. The compact CHARM format allows seamless integration into DeltaV racks while maintaining a minimal CHARM bus power draw. With broad environmental tolerance and robust resistance to shock, vibration, and airborne contaminants, it provides reliable temperature measurement in industrial conditions.
Technical Specifications
-
Model: KL3106X1-LS1
-
Module Type: Intrinsically Safe (I.S.) Analog Input CHARM
-
Signal Type: Thermocouple input (supports multiple types)
-
Safety Type: Intrinsically Safe (I.S.)
-
CHARM Bus Power: +6.3 VDC at minimal consumption
-
Field Circuit Power: +24 VDC, ~60 mA
-
Channels: Single-channel CHARM
-
Terminal Block Key Position: LS1
-
Operating Temperature: –40 °C to +70 °C
-
Humidity: 5–95% RH, non-condensing
-
Shock Resistance: 10 g, half-sine wave, 11 ms
-
Vibration: 2–13.2 Hz: 1 mm peak-to-peak; 13.2–150 Hz: 0.7 g
-
Airborne Contaminants: ISA-S71.04-1985 Class G3
-
Maintenance: No calibration required; no user-serviceable parts
Safety & Compliance
-
Hazardous Atmosphere Ratings:
-
II 3(1) G Ex ec [ia Ga] IIC Gc
-
II 3G (1D) Ex ec [ia IIIC Da] IIC Gc
-
Class I, Division 2, Groups A–D
-
Zone 2 AEx ec [ia Ga] IIC Gc
-
Certifications: ATEX, IECEx, FM, UKEX
-
Installation Note: Do not insert or remove while energized unless area is verified non-hazardous
Key Highlights
-
Single-channel thermocouple input for accurate temperature monitoring
-
Intrinsically safe design for hazardous area applications
-
LS1 keyed terminal block ensures proper wiring and safe installation
-
Broad environmental tolerance: –40 °C to +70 °C; resistant to shock, vibration, and Class G3 airborne contaminants
-
Compact CHARM module for seamless DeltaV system integration
Applications
-
Temperature measurement in hazardous areas using thermocouples
-
Integration into DeltaV I/O systems for process control
-
Suitable for oil, gas, chemical, and other Zone 2 / Class I Div. 2 industrial environments
FAQ
Q: Which thermocouple types are compatible with KL3106X1-LS1?
A: Supports standard thermocouples including types J, K, T, E, R, S, B, and N depending on configuration.
Q: Can this module be installed in Zone 2 locations?
A: Yes, it is certified for Zone 2 and Class I Division 2 hazardous areas.
Q: Is calibration required before operation?
A: No, the module is factory-calibrated and maintenance-free.
الميزات
نحن نرحب بالطلبات الكبيرة ولدينا حد أدنى للطلب يبلغ وحدة واحدة فقط.
عند الطلب، يمكننا توفير جميع الوثائق اللازمة، بما في ذلك شهادات المنشأ/المطابقة وغيرها من مستندات التصدير المطلوبة.
بالنسبة للعناصر المتوفرة في المخزون، نهدف إلى التسليم خلال 1-3 أيام بعد تأكيد الدفع. سيتم تسليم العناصر التي لها أوقات انتظار محددة وفقًا للجدول المقتبس.
نحن نقبل الدفع بنسبة 100% عن طريق التحويل البرقي (T/T) قبل الشحن. بالنسبة للعناصر التي لها أوقات انتظار، يتطلب دفع 30% كدفعة مقدمة، مع دفع الـ 70% المتبقية قبل الشحن. بالنسبة لتحويلات اليوان الصيني (RMB)، يرجى الاتصال بنا إذا كان لديك وكيل في الصين.
نحن نقدم ضمانًا قياسيًا لمدة سنة واحدة على جميع العناصر الجديدة والأصلية. إذا كنت بحاجة إلى ضمان ممتد، يرجى الاتصال بنا للحصول على تفاصيل التكلفة الإضافية.
رضاكم مهم بالنسبة لنا. إذا كنت بحاجة إلى إرجاع عنصر، يجب أن يتم ذلك خلال 30 يومًا من تاريخ الطلب. يجب أن يكون المنتج غير مستخدم، غير مفتوح، وفي عبوته الأصلية مع جميع الملحقات المرفقة. تتم معالجة المبالغ المستردة خلال 5-7 أيام عمل بعد استلامنا للعنصر المُعاد. يرجى ملاحظة أن رسوم الشحن والرسوم ذات الصلة غير قابلة للاسترداد.