{"product_id":"foxboro-fbm206-p0916cq-16-channel-analog-input-module","title":"Foxboro FBM206 P0916CQ 16-Channel Analog Input Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFoxboro FBM206\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003eP0916CQ\u003c\/strong\u003e) is a 16-channel analog input module engineered for the Foxboro I\/A Series Distributed Control System (DCS). It accurately captures 4–20 mA DC signals from industrial transmitters, providing precise, isolated measurements of key process variables such as pressure, flow, temperature, and level.\u003c\/p\u003e\n\u003cp\u003eEach input channel is fully isolated, preventing interference between channels and ensuring high immunity to electrical noise. This design guarantees reliable operation even in harsh industrial environments. The module’s architecture supports hot-swapping and field replacement, allowing maintenance without shutting down the control system.\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFBM206\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis widely deployed in oil \u0026amp; gas, petrochemical, power generation, water treatment, and other process-critical industries. Its high accuracy, long-term stability, and compatibility with redundant FBM configurations make it a dependable choice for mission-critical analog signal acquisition.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications – FBM206 \/ P0916CQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eFBM206\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eP0916CQ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003e16-Channel Analog Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal\u003c\/td\u003e\n\u003ctd\u003e4–20 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e16 isolated analog inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e250 Ω nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1% of reading (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e12-bit or better\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eChannel-to-channel and channel-to-system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Rate\u003c\/td\u003e\n\u003ctd\u003eSynchronized with CP scan (~100 ms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e~3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e–20 °C to +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e–40 °C to +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5–95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMI\/Noise Immunity\u003c\/td\u003e\n\u003ctd\u003eIndustrial-grade, IEC-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eFBM baseplate \/ carrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e5.5 × 2.5 × 6 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaintenance\u003c\/td\u003e\n\u003ctd\u003eHot-swappable, field-replaceable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e16 fully isolated 4–20 mA input channels\u003cbr\u003eHigh-accuracy analog measurement with long-term stability\u003cbr\u003eChannel-to-channel isolation for superior noise immunity\u003cbr\u003eHot-swappable design for continuous plant operation\u003cbr\u003eRugged construction for demanding industrial conditions\u003cbr\u003eSeamless integration with Foxboro I\/A Series DCS\u003cbr\u003eSupports redundant configurations with multiple FBMs\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003ePressure transmitters\u003cbr\u003eFlow measurement devices\u003cbr\u003eTemperature transmitters (via 4–20 mA converters)\u003cbr\u003eLevel sensing instrumentation\u003cbr\u003eAnalyzer output signals\u003cbr\u003eAny industrial 4–20 mA measurement systems\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eEnsures signal integrity under high EMI environments\u003cbr\u003eField-replaceable module without system downtime\u003cbr\u003eRedundant configurations enhance system reliability\u003cbr\u003eCompatible with a wide range of analog process instruments\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eQ: How many channels does\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFBM206 \/ P0916CQ\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupport?\u003cbr\u003eA: The module provides 16 fully isolated analog input channels.\u003c\/p\u003e\n\u003cp\u003eQ: Can it handle redundant configurations?\u003cbr\u003eA: Yes, it supports redundancy when paired with additional FBM modules.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum operating temperature?\u003cbr\u003eA: Standard operation is up to +70 °C.\u003c\/p\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":43170846179418,"sku":"FBM206 P0916CQ","price":177.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/FBM206P0916CQ1.jpg?v=1775118444","url":"https:\/\/www.plcmasters.com\/ar\/products\/foxboro-fbm206-p0916cq-16-channel-analog-input-module","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}