الوصف
Overview
The UR8FV CT/VT module from GE Multilin is a dedicated measurement interface designed for the UR Series Universal Relay platform. It integrates current and voltage sensing functions into a single hardware module, allowing the relay to acquire precise electrical parameters required for protection, metering, and system diagnostics in medium- and high-voltage power networks.
Engineered for substation-grade reliability, this module supports both phase and ground current measurement along with voltage inputs, ensuring accurate real-time data for protective algorithms and control logic.
Key Functions and Capabilities
The UR8FV module delivers combined current and voltage measurement through a compact design that minimizes wiring complexity and panel space. It supports standard secondary current ratings and voltage transformer connections commonly used in protection systems, enabling seamless integration with existing CTs and VTs.
The module is not a standalone device; it operates as part of the GE Multilin UR relay hardware architecture and communicates directly with the relay processor for protection, monitoring, and recording functions.
Technical Specifications
-
Phase Current Inputs: Three phase CT channels, configurable for 1 A or 5 A nominal secondary
-
Ground Current Input: One dedicated ground CT channel, configurable for 1 A or 5 A
-
Voltage Inputs: Four-terminal VT input for phase or line voltage measurement
-
Measurement Functions: RMS current and voltage measurement, phase and ground monitoring
-
System Compatibility: GE Multilin UR Series Universal Relays
-
Electrical Environment: AC power systems in substations and industrial power distribution
-
Installation: Plug-in module for UR relay chassis
-
Reliability Class: Designed for continuous operation in utility-grade environments
Applications
The UR8FV CT/VT module is commonly used in:
-
Transmission and distribution substations
-
Generator and transformer protection schemes
-
Feeder protection and monitoring
-
Industrial power systems requiring integrated current and voltage measurement
Installation and Engineering Notes
Correct CT polarity, VT wiring, and relay configuration are essential to ensure accurate measurements and dependable protection operation. Secondary current ratings must match relay settings to avoid scaling errors. Commissioning tests are recommended after installation.
FAQ
Is the UR8FV a complete protection relay?
No. The UR8FV is a measurement module that operates only when installed in a compatible GE Multilin UR Series relay.
Does the module support both 1 A and 5 A CTs?
Yes. The UR8FV supports standard 1 A and 5 A secondary CT inputs through configuration.
Can this module be used outside the UR Series platform?
No. It is specifically designed for electrical and mechanical compatibility with GE Multilin UR Series relays.
الميزات
نحن نرحب بالطلبات الكبيرة ولدينا حد أدنى للطلب يبلغ وحدة واحدة فقط.
عند الطلب، يمكننا توفير جميع الوثائق اللازمة، بما في ذلك شهادات المنشأ/المطابقة وغيرها من مستندات التصدير المطلوبة.
بالنسبة للعناصر المتوفرة في المخزون، نهدف إلى التسليم خلال 1-3 أيام بعد تأكيد الدفع. سيتم تسليم العناصر التي لها أوقات انتظار محددة وفقًا للجدول المقتبس.
نحن نقبل الدفع بنسبة 100% عن طريق التحويل البرقي (T/T) قبل الشحن. بالنسبة للعناصر التي لها أوقات انتظار، يتطلب دفع 30% كدفعة مقدمة، مع دفع الـ 70% المتبقية قبل الشحن. بالنسبة لتحويلات اليوان الصيني (RMB)، يرجى الاتصال بنا إذا كان لديك وكيل في الصين.
نحن نقدم ضمانًا قياسيًا لمدة سنة واحدة على جميع العناصر الجديدة والأصلية. إذا كنت بحاجة إلى ضمان ممتد، يرجى الاتصال بنا للحصول على تفاصيل التكلفة الإضافية.
رضاكم مهم بالنسبة لنا. إذا كنت بحاجة إلى إرجاع عنصر، يجب أن يتم ذلك خلال 30 يومًا من تاريخ الطلب. يجب أن يكون المنتج غير مستخدم، غير مفتوح، وفي عبوته الأصلية مع جميع الملحقات المرفقة. تتم معالجة المبالغ المستردة خلال 5-7 أيام عمل بعد استلامنا للعنصر المُعاد. يرجى ملاحظة أن رسوم الشحن والرسوم ذات الصلة غير قابلة للاسترداد.