{"title":"ProSoft","description":"\u003cp\u003eProSoft Technology specializes in industrial communication solutions for automation and control, offering products like in-chassis modules for Rockwell Automation and Schneider Electric platforms, protocol gateways for interoperability between different systems, and industrial wireless solutions for reliable communication in harsh environments.\u003c\/p\u003e","products":[{"product_id":"allen-bradley-mvi56e-afc-enhanced-liquid-and-gas-flow-computer","title":"Allen-Bradley ProSoft MVI56E-AFC Enhanced Liquid and Gas Flow Computer","description":"\u003cp\u003e\u003cstrong\u003eOverview:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePowerful device for industrial flow measurement\u003c\/li\u003e\n\u003cli\u003eCombines analog inputs, pulse inputs, and communication capabilities\u003c\/li\u003e\n\u003cli\u003eSuitable for accurate calculation and monitoring of flow rates for liquids and gases\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess I\/O\u003c\/strong\u003e: Analog inputs (pressure, temperature, differential pressure, density) from analog modules and pulse inputs from pulse\/frequency input modules in rack\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Meter Channels\u003c\/strong\u003e: 8 or 16 meters (differential (AGA3 or ISO5167) or linear (AGA7) Gas; (MPMS Ch 12.2) Liquid)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eHardware Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Current Load\u003c\/strong\u003e: 800 mA @ 5 Vdc, 3 mA @ 24 Vdc\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 0°C to 60°C (32°F to 140°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e: -40°C to 85°C (-40°F to 185°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShock\u003c\/strong\u003e: 30 g operational, 50 g non-operational\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration\u003c\/strong\u003e: 5 g from 10 Hz to 150 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e: 5% to 95% (with no condensation)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLED Indicators\u003c\/strong\u003e: Module Status, Backplane Transfer Status, Application Status, Serial Activity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication Ports (MODBUS 1 \u0026amp; MODBUS 2)\u003c\/strong\u003e: Full hardware handshaking control, providing radio, modem, and multi-drop support\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApp Ports (MODBUS 1 \u0026amp; MODBUS 2)\u003c\/strong\u003e: RJ45 (DB-9M with supplied cable), RS-232, RS-485, RS-422 jumper selectable, RS-232 handshaking configurable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation\u003c\/strong\u003e: 500 V Optical isolation from backplane\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncluded Cables\u003c\/strong\u003e: RJ45 to DB-9M cables for each port\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":41406039752794,"sku":"MVI56E-AFC","price":183.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/MVI56E-AFC.jpg?v=1741000718"},{"product_id":"allen-bradley-mvi56-adm-prosoft-controllogix-inrax-c-app-dev-2xrs232-422-485","title":"Allen-Bradley MVI56-ADM Prosoft Controllogix INRAX C APP DEV 2xRS232\/422\/485","description":"\u003cp\u003e\u003cstrong\u003eOverview:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCommunication module for industrial automation applications\u003c\/li\u003e\n\u003cli\u003eProvides two serial communication ports configurable for RS-232, RS-422, or RS-485\u003c\/li\u003e\n\u003cli\u003eEnables seamless integration with various devices and systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Rockwell Automation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: Allen-Bradley\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number\/Catalog No.\u003c\/strong\u003e: MVI56-ADM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: 'C' Programmable Application Development Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlots\u003c\/strong\u003e: 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Type\u003c\/strong\u003e: Local or Remote\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Transfer Type\u003c\/strong\u003e: Ladder Logic\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBaud Rate\u003c\/strong\u003e: 110 to 115,200\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptical Isolation from Backplane\u003c\/strong\u003e: 500V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCFG Port\u003c\/strong\u003e: RJ45\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShock\u003c\/strong\u003e: 30g Operational\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Current Load\u003c\/strong\u003e: 800 mA at 5 Volts DC\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":41406043652186,"sku":"MVI56-ADM","price":158.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/MVI56-ADM.jpg?v=1741000716"},{"product_id":"allen-bradley-1734-ob4e-output-module","title":"Allen-Bradley 1734-OB4E Output Module","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1734-OB4E\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a digital output module from the POINT I\/O series, designed for high-speed and precise control of digital outputs in industrial automation systems. With four current-sourcing output channels, this module ensures reliable performance in demanding applications.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-OB4E\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eType\u003c\/strong\u003e: Digital Output Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Channels\u003c\/strong\u003e: 4 outputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Voltage Range\u003c\/strong\u003e: 10-28.8 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Current\u003c\/strong\u003e: 1 A per channel, 3 A total per module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Protocol\u003c\/strong\u003e: Compatible with POINT I\/O systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: -20°C to +55°C (-4°F to +131°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e: 24 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e: 24 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum OFF-state Leakage\u003c\/strong\u003e: 0.5 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMax OFF-state Voltage\u003c\/strong\u003e: 28.8 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOn-state Current\u003c\/strong\u003e: 1.0 mA min per channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOn-state Voltage Drop\u003c\/strong\u003e: 0.2 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePointBus Current\u003c\/strong\u003e: 75 mA max at 5 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e: 1.2W max at 28.8 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Dissipation\u003c\/strong\u003e: 4.1 BTU\/hour max at 28.8 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Style\u003c\/strong\u003e: DIN Rail Mount\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e: Current Sourcing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":41406048567386,"sku":"1734-OB4E","price":185.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/Allen-Bradley1734-OB4E.jpg?v=1741776289"},{"product_id":"allen-bradley-mvi69-mnet-modbus-tcp-ip-communication-module","title":"Allen-Bradley ProSoft MVI69-MNET Modbus TCP\/IP Communication Module","description":"\u003cp\u003e\u003cstrong\u003eOverview:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAllen-Bradley MVI69-MNET Modbus TCP\/IP Communication Module for Allen-Bradley PLC systems\u003c\/li\u003e\n\u003cli\u003eFacilitates communication with Modbus-compatible devices\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e Standard 1769 single-slot module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Load:\u003c\/strong\u003e 800 mA max @ 5 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply Distance Rating:\u003c\/strong\u003e 2 (L43 and L45 installations on first 2 slots of 1769 bus)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to 60°C (32°F to 140°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to 85°C (-40°F to 185°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative Humidity:\u003c\/strong\u003e 5% to 95% (non-condensing)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLED Indicators:\u003c\/strong\u003e Power and Module Status, Application Status, CFG Port Activity, Ethernet Port Activity, Error Status\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCFG Port:\u003c\/strong\u003e RJ45 (DB-9M with supplied cable), RS-232 only, no hardware handshaking\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApp Port (Ethernet modules):\u003c\/strong\u003e 10\/100 Base-T Ethernet compatible interface\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Isolation:\u003c\/strong\u003e 1500 Vrms at 50 Hz to 60 Hz for 60 s (IEC 60950: 1991)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet Broadcast Storm Resiliency:\u003c\/strong\u003e ≤ 5000 [ARP] frames-per-second, ≤ 5 minutes duration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncluded Cables:\u003c\/strong\u003e RJ45 to DB-9M cables for each port\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRS-232 Configuration Cable:\u003c\/strong\u003e 6-foot RS-232 configuration cable\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":41406055940186,"sku":"MVI69-MNET","price":185.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/MVI69-MNET_2.jpg?v=1741000714"},{"product_id":"allen-bradley-mvi56-gsc-ommunication-module","title":"Allen-Bradley MVI56-GSC ommunication module","description":"\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley MVI56-GSC\u003c\/strong\u003e is a communication module designed for the ControlLogix platform, enabling connectivity with various protocols.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFunctionality\u003c\/strong\u003e: This module allows for seamless communication between ControlLogix systems and General Motors (GSC) systems, facilitating data exchange and integration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eType\u003c\/strong\u003e: It supports multiple communication protocols, making it versatile for different industrial applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance\u003c\/strong\u003e: Known for its reliability, the MVI56-GSC ensures efficient data transfer and minimal downtime.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDesign\u003c\/strong\u003e: Compact and easy to install, this module fits within the ControlLogix chassis, optimizing panel space.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e: Commonly used in automotive manufacturing and other industries requiring robust communication solutions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe \u003cstrong\u003eMVI56-GSC\u003c\/strong\u003e enhances Allen-Bradley's automation offerings by providing essential connectivity, supporting improved operational efficiency and system integration.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":41450951475290,"sku":"MVI56-GSC","price":168.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/MVI56-ADM.jpg?v=1741000716"},{"product_id":"prosoft-mvi56-hart-hart-multi-drop-master-communication-module","title":"ProSoft MVI56-HART HART Multi-drop Master Communication Module","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ProSoft \u003cstrong\u003eMVI56-HART\u003c\/strong\u003e is a HART Multi-drop Master Communication Module designed for industrial automation systems. It facilitates communication with HART-compatible devices, ensuring reliable data transfer and integration within a control system.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• \u003cstrong\u003eBackplane Current Load:\u003c\/strong\u003e 800 mA @ 5 V DC, 3 mA @ 24 V DC\u003cbr\u003e• \u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0 to 60°C (32 to 140°F)\u003cbr\u003e• \u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40 to 85°C (-40 to 185°F)\u003cbr\u003e• \u003cstrong\u003eShock:\u003c\/strong\u003e 30g Operational, 50g Non-operational\u003cbr\u003e• \u003cstrong\u003eVibration:\u003c\/strong\u003e 5 g from 10 to 150 Hz\u003cbr\u003e• \u003cstrong\u003eRelative Humidity:\u003c\/strong\u003e 5% to 95% (non-condensing)\u003cbr\u003e• \u003cstrong\u003eLED Indicators:\u003c\/strong\u003e Module Status, Backplane Transfer Status, Application Status, Serial Activity\u003cbr\u003e• \u003cstrong\u003eDebug\/Configuration Port (CFG):\u003c\/strong\u003e RJ45 (DB-9M with supplied cable), RS-232 only, No hardware handshaking\u003cbr\u003e• \u003cstrong\u003eConfiguration Connector:\u003c\/strong\u003e RJ45 RS-232 Connector (RJ45 to DB-9 cable shipped with unit)\u003cbr\u003e• \u003cstrong\u003eApplication Ports:\u003c\/strong\u003e HART terminal connector\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":41477137498202,"sku":"MVI56-HART","price":185.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/MVI56-HART_2.jpg?v=1740999673"},{"product_id":"prosoft-5201-dfnt-mcm-ethernet-ip-to-modbus-master-slave-gateway-module","title":"PROSOFT 5201-DFNT-MCM Ethernet\/IP to Modbus Master\/Slave Gateway Module","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eProSoft 5201-DFNT-MCM\u003c\/strong\u003e is an Ethernet\/IP to Modbus Master\/Slave gateway module. It facilitates communication between EtherNet\/IP and Modbus devices, allowing seamless integration across different industrial networks. Designed for easy installation on DIN rails, the module supports various industrial applications, including manufacturing, oil and gas, electrical power, and food processing. With features like multiple communication ports, LED status indicators, and a broad operating temperature range, this module ensures reliable operation in demanding environments.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number\u003c\/strong\u003e: \u003cstrong\u003e5201-DFNT-MCM\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory\u003c\/strong\u003e: PLCs\/Machine Control\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSubcategory\u003c\/strong\u003e: PLC Module\/Rack\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e: 0.97 lbs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eCommunication and Ports\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol\u003c\/strong\u003e: Ethernet\/IP and Modbus Master\/Slave (MCM)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet Port\u003c\/strong\u003e: 1 x 10Base-T half-duplex RJ45, link and activity LEDs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial Ports\u003c\/strong\u003e: 2 x DB9 female Modbus Plus connectors, RS-232\/RS-422\/RS-485\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Transfer Rate\u003c\/strong\u003e: 110-115 kbps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Isolation\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e1500 Vrms (Ethernet port)\u003c\/li\u003e\n\u003cli\u003e2500 Vrms (Modbus port)\u003c\/li\u003e\n\u003cli\u003e3000 VDC minimum port-to-ground and port-to-logic isolation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply\u003c\/strong\u003e: 18 to 32 VDC via screw terminals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption\u003c\/strong\u003e: Requires a 2.5 mm screwdriver blade for power connections\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Rating\u003c\/strong\u003e: 50\/60 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eOperating Conditions\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: -4°F to 122°F (-20°C to 50°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity\u003c\/strong\u003e: 5% to 95% relative humidity (non-condensing)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting\u003c\/strong\u003e: DIN rail mountable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eIndicators\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLED Status Indicators\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003ePower and module status\u003c\/li\u003e\n\u003cli\u003eApplication status\u003c\/li\u003e\n\u003cli\u003eSerial port activity and error status\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications\u003c\/strong\u003e: ATEX, CE\/EMC, UL, GOST-R\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliance\u003c\/strong\u003e: Meets various international standards for safety and electromagnetic compatibility.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions\u003c\/strong\u003e: 5.2 inches (H) x 2.07 inches (W) x 4.52 inches (D) \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eManufacturing\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eOil and Gas\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eElectrical Power\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eFood Processing\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":41512640970842,"sku":"5201-DFNT-MCM","price":186.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/PROSOFT5201-DFNT-MCM2.jpg?v=1740999174"},{"product_id":"allen-bradley-prosoft-mvi69-mcm-master-slave-network-interface-module","title":"Allen-Bradley ProSoft MVI69-MCM Master\/Slave Network Interface Module","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003eThe \u003cstrong\u003eProSoft MVI69-MCM\u003c\/strong\u003e is a versatile Modbus Master\/Slave Network Interface Module designed to interface with Modbus-compatible devices. It allows Rockwell Automation’s \u003cstrong\u003eCompactLogix\u003c\/strong\u003e and \u003cstrong\u003eMicroLogix\u003c\/strong\u003e controllers to communicate with a wide range of Modbus devices, including both Modicon PLCs and third-party devices. The module supports both Modbus Master and Slave configurations, enabling it to manage and interact with multiple devices on the same network. Its flexible compatibility and reliable performance make it ideal for applications in industrial automation systems.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Rockwell Automation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: Allen-Bradley\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number\u003c\/strong\u003e: \u003cstrong\u003eMVI69-MCM\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Modbus Master\/Slave Network Interface Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility\u003c\/strong\u003e: Works with CompactLogix and MicroLogix controllers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot Type\u003c\/strong\u003e: 1-slot module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Transfer\u003c\/strong\u003e: Supports Ladder Logic programming\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBaud Rate\u003c\/strong\u003e: 110 to 115K baud\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNode Address\u003c\/strong\u003e: Supports address range 1-247\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions\u003c\/strong\u003e: Standard 1769 Single-slot Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Load\u003c\/strong\u003e: Maximum 800 mA at 5 VDC\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":41580260425818,"sku":"MVI69-MCM","price":185.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/ProSoftMVI69-MCM1.jpg?v=1740998312"},{"product_id":"prosoft-mvi56-gec-communications-interface-module","title":"PROSOFT MVI56-GEC Communications Interface Module","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMVI56-GEC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance Ethernet communications interface module designed for seamless integration of ASCII devices with Allen-Bradley ControlLogix PLC systems. It features a single slot and supports both local and remote rack configurations. The module enables reliable data transfer using ladder logic and provides connectivity through a 10\/100MB Ethernet interface. It is ideal for applications requiring efficient and reliable communication between control systems and external ASCII devices.\u003c\/p\u003e\n\u003ch3 class=\"\"\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Rockwell Automation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e: Allen-Bradley\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMVI56-GEC\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Generic ASCII Ethernet Communications Interface Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eSlot(s)\u003c\/strong\u003e: 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eRack Type\u003c\/strong\u003e: Local or Remote\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eData Transfer Type\u003c\/strong\u003e: Ladder Logic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eEthernet Interface\u003c\/strong\u003e: 10\/100MB Ethernet-compatible\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eBaud Rate\u003c\/strong\u003e: 110 - 115,200 bps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e3 mA at 24 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e800 mA at 5 VDC (from backplane)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eOptical Isolation\u003c\/strong\u003e: 500V from backplane\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eBackplane Current Load\u003c\/strong\u003e: 800 mA at 5 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eShock\u003c\/strong\u003e: 30g (Operational)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: 0.62 lbs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003ePorts\u003c\/strong\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eEthernet Port\u003c\/strong\u003e: Supports full hardware handshaking, with link and activity LEDs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eConfiguration Port (CFG)\u003c\/strong\u003e: Debug\/Configuration RJ45 port (does not support hardware handshaking)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eEnvironmental Compliance\u003c\/strong\u003e: Suitable for harsh industrial environments with operational resilience\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":41840924164186,"sku":"MVI56-GEC","price":169.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/PROSOFTMVI56-GEC.jpg?v=1744095402"},{"product_id":"prosoft-3100-mcm-modbus-master-slave-communication-module","title":"ProSoft 3100-MCM Modbus Master\/Slave Communication Module","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eProSoft 3100-MCM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a Modbus Master\/Slave Communication Module. It allows Rockwell Automation PLCs to connect with Modbus-compatible devices. The module works as an input\/output bridge between the Modbus network and the Rockwell backplane. It ensures fast and reliable data exchange.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProSoft Technology\u003cbr\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3100-MCM\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eFunction:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eModbus Master\/Slave Communication Module\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSupported Protocols:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eModbus RTU\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eModbus ASCII\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Interfaces:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRS-232C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRS-422\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRS-485\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCommand List Capacity:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eUp to 100 fully configurable entries\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eData Storage Capacity:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eUp to 4000 registers for PLC data\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePolling Method:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePerforms continuous polling of the command list\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eError Handling:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSends error codes to ladder logic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports event-driven bit and register write\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Type:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRack-mounted in Rockwell Automation backplane\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Ratings:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0°C to 60°C (32°F to 140°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-40°C to 85°C (-40°F to 185°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRelative Humidity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5% to 95% (non-condensing)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShock:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e30g operational, 50g non-operational\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVibration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5g from 10 Hz to 150 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":41989004820570,"sku":"3100-MCM","price":194.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/3100-MCM.jpg?v=1749541801"},{"product_id":"prosoft-plx31-efp-mbs-gateway-ethernet-ip-to-modbus-serial","title":"PROSOFT PLX31-EFP-MBS Gateway Ethernet\/IP to Modbus Serial","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eProSoft PLX31-EFP-MBS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eacts as a high-speed gateway between EtherNet\/IP PACs and Modbus Serial devices. It supports bidirectional communication for Rockwell Automation ControlLogix® and CompactLogix™ controllers. This gateway ensures reliable data exchange across industrial networks.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eEtherNet\/IP Interface:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSupports 5 Class 3 server connections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports 2 connected and 1 unconnected Class 3 client connections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports 2 Class 1 I\/O connections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaximum I\/O size: 248 bytes input\/output\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaximum RPI time: 5 ms per connection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports CIP Data Table Read (0x4C) and Write (0x4D)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModbus Serial Interface:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSupports function codes: 1, 2, 3, 4, 5, 6, 15, 16, 22, 23\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBaud rate range: 110 to 115.2 kbps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eParity options: None, Even, Odd\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eData bits: 7 or 8\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStop bits: 1 or 2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCommunication modes: RTU (CRC-16), ASCII (LRC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFloating point formats: Enron, Daniel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSlave address range: 1 to 247\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInterfaces: RS232, RS422, RS485\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eHardware \u0026amp; Power:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePower supply: 24 VDC nominal (10–36 VDC acceptable)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCurrent draw: 300 mA nominal, 610 mA max\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating temperature: -25°C to +70°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage temperature: -40°C to +80°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHumidity: 5% to 95% RH (non-condensing)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDimensions: 5.38 × 1.99 × 4.38 in (13.67 × 5.05 × 11.13 cm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnclosure rating: IP20, NEMA\/UL Open Type\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMounting: DIN Rail mountable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":42000186671194,"sku":"PLX31-EFP-MBS","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/PLX31-EFP-MBS.jpg?v=1750145218"},{"product_id":"prosoft-5601-rio-mcm-industrial-gateway-module","title":"PROSOFT 5601-RIO-MCM Industrial Gateway Module","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePROSOFT 5601-RIO-MCM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance industrial gateway module. It actively bridges Rockwell Automation Remote I\/O networks with Modbus Master\/Slave devices. This module integrates Modbus-compatible equipment into Remote I\/O systems efficiently. Therefore, it suits complex industrial environments such as manufacturing, energy, and process control.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSupported Protocols\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eModbus TCP\/IP, RTU, EtherNet\/IP, DNP3\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Modes\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePoint-to-point, Broadcast, Multicast\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eData Formats\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eBinary, BCD, ASCII\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSecurity Protocols\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSSL, TLS, IPsec\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage Range\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e18–32 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDIN-rail\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePorts\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 Remote I\/O port, up to 4 serial ports\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e-20°C to 50°C (-4°F to 122°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e-40°C to 85°C (-40°F to 185°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e5% to 95% RH, non-condensing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e24 VDC nominal, supports 18–32 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Load\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMaximum 500 mA @ 32 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions (Standard)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e132 mm H x 52.5 mm W x 114.8 mm D\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eNumber of Ports\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eUp to 4 serial ports\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModbus Modes\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRTU (binary) with CRC-16, ASCII with LRC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFunction Codes\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRead Coil Status (1), Read Input Status (2), Read Holding Registers (3), Read Input Registers (4)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eBaud Rate\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e110 to 115K baud\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eData Size\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e7 or 8 bits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":42170200490074,"sku":"5601-RIO-MCM","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/5601-RIO-MCM.jpg?v=1755154813"},{"product_id":"prosoft-5301-mbp-dfcm-specialty-protocol-gateway","title":"PROSOFT 5301-MBP-DFCM Specialty Protocol Gateway","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe ProSoft 5301‑MBP‑DFCM is a specialty protocol gateway designed to seamlessly connect Allen‑Bradley PLCs using DF1 protocol with Modbus Plus networks. It ensures reliable, high-speed data exchange between legacy and modern industrial devices. Moreover, its flexible DF1 Master and Slave modes allow engineers to integrate mixed-vendor systems without complex reprogramming. Rugged and compact, this gateway supports both DIN-rail and panel installation for industrial environments.\u003c\/p\u003e\n\u003ch3\u003eKey Features \u0026amp; Functional Highlights\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eBridges DF1-based Allen‑Bradley PLCs with Modbus Plus devices efficiently.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports DF1 Master and DF1 Slave configurations for flexible system integration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStand-alone gateway with its own processor and memory ensures stable performance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAdvanced diagnostics and monitoring tools simplify troubleshooting and maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRugged design withstands industrial temperature, humidity, and vibration conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eManaged via ProSoft Configuration Builder (PCB) software for simple setup.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSupported Protocols:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDF1 (Master\/Slave), Modbus Plus\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePorts:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOne DF1 serial port (RS‑232\/RS‑422\/RS‑485 configurable)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOne Modbus Plus port (peer-to-peer communication)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eData Handling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUp to 4000 registers for data exchange\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh-speed transfer between DF1 and Modbus Plus devices\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24 VDC nominal (18–36 VDC range)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e−20 °C to +60 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e−40 °C to +85 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHumidity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5% to 95% non-condensing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e 127 × 102 × 51 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 4.54 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOil \u0026amp; Gas:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrate Allen‑Bradley PLCs with Modicon systems in pipelines or refineries.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Generation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBridge communication between legacy PLCs and modern Modbus Plus devices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChemical \u0026amp; Petrochemical:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnable SCADA across multi-vendor industrial controllers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWater Treatment:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eLink DF1 controllers to Modbus Plus networks for monitoring and control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this gateway operate as both DF1 Master and Slave simultaneously?\u003c\/strong\u003e\u003cbr\u003eA: No, it supports either DF1 Master or Slave mode, configurable via PCB software.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many data registers can it handle?\u003c\/strong\u003e\u003cbr\u003eA: The gateway supports up to 4000 registers for seamless data exchange.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is installation flexible in industrial environments?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it can be mounted on a DIN-rail or panel for easy deployment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does it provide diagnostics for troubleshooting?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the gateway includes monitoring tools to simplify system diagnostics.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":42613141569626,"sku":"5301-MBP-DFCM","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/5301-MBP-DFCM2.jpg?v=1764663093"},{"product_id":"prosoft-mvi69-pdps-profibus-dp-slave-communication-module","title":"PROSOFT MVI69-PDPS PROFIBUS DP Slave Communication Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe ProSoft MVI69‑PDPS is a PROFIBUS DP Slave Communication Module designed specifically for Rockwell Automation CompactLogix and MicroLogix 1500 controllers. It enables seamless and reliable integration of Rockwell PLCs into PROFIBUS DP networks, facilitating consistent data exchange between devices from multiple vendors. Moreover, its rugged construction ensures stable operation in demanding industrial environments. The module’s user-friendly configuration, through ProSoft Configuration Builder (PCB), allows engineers to deploy complex networks efficiently.\u003c\/p\u003e\n\u003ch3\u003eKey Features \u0026amp; Functional Highlights\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eActs as a PROFIBUS DP V0 slave device, ensuring full network compatibility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports up to 244 bytes of input and output data for flexible system integration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSingle-slot design enables quick installation within 1769 backplanes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBuilt-in diagnostics simplify troubleshooting, improving operational uptime.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWide operating temperature and humidity tolerance ensure reliable field performance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRJ45 configuration port allows simple RS-232 setup without additional hardware.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProSoft MVI69‑PDPS\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eType:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePROFIBUS DP Slave Communication Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCompactLogix and MicroLogix 1500 controllers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork Protocol:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePROFIBUS DP V0 (Slave)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eData Capacity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e244 bytes input \/ 244 bytes output\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInternal Database:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e400 registers (words) available\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBackplane Current Load:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e~800 mA @ 5 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProvided via 1769 backplane\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0 °C to 60 °C (32 °F to 140 °F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e−40 °C to 85 °C (−40 °F to 185 °F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHumidity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5% to 95% non-condensing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Baud Rate:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e9.6 kbps to 12 Mbps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eForm Factor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSingle-slot, 1769 backplane compatible\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLED Indicators:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePower, Module Status, Application Status, Serial Port Activity, Error Status\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.5 Kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConfiguration Software:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProSoft Configuration Builder (PCB)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower \u0026amp; Distribution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrate CompactLogix controllers into PROFIBUS-enabled substations for reliable monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePetrochemical Plants:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConnect Rockwell PLCs to mixed-vendor PROFIBUS DP systems for supervisory control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWater \u0026amp; Gas Utilities:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnable seamless communication between controllers and field devices for automated management.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSCADA\/DCS Systems:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnhance cross-platform data exchange for control and reporting purposes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Which Rockwell controllers are compatible with MVI69‑PDPS?\u003c\/strong\u003e\u003cbr\u003eA1: It supports CompactLogix and MicroLogix 1500 series, excluding specific models such as 1769-L23E-QBFC1B.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: How do I configure the module?\u003c\/strong\u003e\u003cbr\u003eA2: Use the ProSoft Configuration Builder (PCB) software via the RS-232 CFG port with the included DB-9M cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What is the maximum data throughput?\u003c\/strong\u003e\u003cbr\u003eA3: The module handles up to 244 bytes of input and 244 bytes of output data, depending on system configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Can it operate in harsh industrial conditions?\u003c\/strong\u003e\u003cbr\u003eA4: Yes, it operates between 0 °C to 60 °C and can handle 5%–95% non-condensing humidity.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":42613155037274,"sku":"MVI69-PDPS","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/MVI69-PDPS2.jpg?v=1764663375"},{"product_id":"prosoft-plx32-eip-pnd-protocol-gateway","title":"PROSOFT PLX32-EIP-PND Protocol Gateway","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe ProSoft PLX32‑EIP‑PND is a high-performance protocol gateway designed to connect EtherNet\/IP controllers with PROFIBUS DP devices seamlessly. Engineers rely on this module to simplify network integration while maintaining deterministic communication and real-time data exchange. Its rugged construction ensures reliable operation in demanding industrial environments, from refineries to water treatment plants. Moreover, the module supports comprehensive diagnostics and intuitive configuration, reducing engineering time and minimizing network downtime.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProvides seamless communication between EtherNet\/IP controllers and PROFIBUS DP devices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFunctions as a PROFIBUS DP Master, supporting up to 125 slave devices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnables high-speed, deterministic data exchange for real-time industrial control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfigurable via ProSoft Configuration Builder (PCB) software for streamlined setup.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDual 10\/100 Mbps Ethernet ports allow flexible network topology and redundancy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRugged, industrial-grade design suitable for DIN-rail or panel mounting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBuilt-in diagnostics and monitoring tools simplify troubleshooting and maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtocols Supported:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEtherNet\/IP, PROFIBUS DP (Master)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEtherNet\/IP Ports:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2 × 10\/100 Mbps RJ-45\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePROFIBUS Port:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1 × RS-485 DB9 connector\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMax Devices Supported:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e125 PROFIBUS DP slaves\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eData Capacity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1536 bytes input \/ 1536 bytes output\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEtherNet\/IP I\/O Connections:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8, 496 bytes per connection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMax RPI Time:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5 ms per connection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24 VDC nominal (range 10–36 VDC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Load:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e300 mA nominal, 610 mA max\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e−25 °C to 70 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e−40 °C to +85 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHumidity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5% to 95% non-condensing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e 127 × 102 × 51 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.45 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCertifications:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCE, UL, CSA, hazardous location approvals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOil \u0026amp; Gas:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConnects Rockwell controllers with PROFIBUS field devices in pipelines and refineries.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Generation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBridges EtherNet\/IP PLCs with PROFIBUS instrumentation for plant control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChemical \u0026amp; Petrochemical:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports mixed-vendor system integration for supervisory control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWater \u0026amp; Wastewater Treatment:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnables monitoring and control across EtherNet\/IP and PROFIBUS networks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which controllers are compatible with the PLX32‑EIP‑PND?\u003c\/strong\u003e\u003cbr\u003eA: It supports Allen-Bradley CompactLogix, ControlLogix, PLC-5, SLC, and MicroLogix controllers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many PROFIBUS devices can this module manage?\u003c\/strong\u003e\u003cbr\u003eA: The module functions as a PROFIBUS DP Master and supports up to 125 slave devices.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the gateway suitable for harsh industrial environments?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it features a rugged industrial design with wide temperature and humidity tolerance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How is configuration handled?\u003c\/strong\u003e\u003cbr\u003eA: The module is configured using ProSoft Configuration Builder (PCB) software for easy setup.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":42613157167194,"sku":"PLX32-EIP-PND","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/PLX32-EIP-PND2.jpg?v=1764663835"},{"product_id":"prosoft-5204-dfnt-pdpm-prosoft-df1-to-profibus-gateway","title":"ProSoft 5204-DFNT-PDPM | ProSoft DF1 to PROFIBUS Gateway","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe ProSoft\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5204-DFNT-PDPM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a dual-protocol communication gateway engineered to connect Rockwell Automation PLC environments with PROFIBUS-DP field networks. It provides a bidirectional data interface between DF1-over-Ethernet (DFNT) traffic and PROFIBUS-DP Master systems, enabling seamless integration of legacy field devices into modern Ethernet-based control architectures.\u003c\/p\u003e\n\u003cp\u003eThis module is designed for use in ControlLogix, CompactLogix, SLC 500, and PLC-5 platforms via ProSoft in-rack integration. It supports deterministic data exchange, real-time diagnostics, and flexible data mapping for complex multi-vendor automation systems.\u003c\/p\u003e\n\u003ch3\u003eCore Communication Architecture\u003c\/h3\u003e\n\u003cp\u003eDFNT Interface (EtherNet\/IP Layer)\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProtocol: DF1 encapsulated over Ethernet (DFNT)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Mode: Client \/ Server dual operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEthernet Speed: 10\/100 Mbps auto-negotiation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupported Data Types: Integer, Float, Boolean bit-level mapping\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMax Sessions: Up to 10 simultaneous connections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMessaging Support: Structured read\/write of PLC data files and registers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003ePROFIBUS-DP Master Interface\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProtocol: PROFIBUS-DP V0 Master\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBaud Rate Range: 9.6 kbps to 12 Mbps (auto-detection supported)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaximum Slaves: Up to 125 devices per network segment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eData Exchange Size: 244 bytes input \/ 244 bytes output per slave\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfiguration: GSD file-based device integration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDiagnostics: Live node list, bus health monitoring, device status reporting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware \u0026amp; Electrical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eInput Power: 18–32 VDC (nominal 24 VDC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower Consumption: \u0026lt; 5 W typical operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding: Dedicated GND terminals for noise immunity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInterface Terminals: 2.5 mm screw terminal block design\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLED Indicators: Module status, Ethernet link\/activity, PROFIBUS bus state, backplane communication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental \u0026amp; Mechanical Ratings\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: -25°C to +70°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage Temperature: -40°C to +85°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHumidity: 5–95% non-condensing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVibration \u0026amp; Shock: IEC 60068-2 compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMounting: Rack-mounted PLC backplane integration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: 0.90 lbs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCertifications: CE, UL\/cUL, Class I Division 2, ATEX Zone 2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey Functional Features\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-speed PROFIBUS-DP master communication engine\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTransparent data bridging between DF1 Ethernet and PROFIBUS networks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrated diagnostic web tools and configuration utilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge data block handling for high-throughput applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports legacy device modernization without PLC replacement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFully configurable using ProSoft Configuration Builder (PCB)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplication Areas\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProcess automation systems requiring fieldbus integration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOil \u0026amp; gas production and distribution control networks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWater and wastewater treatment plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower generation and substation control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaterial handling and large-scale manufacturing lines\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Can this module connect PROFIBUS devices to ControlLogix PLCs?\u003c\/strong\u003e\u003cbr\u003eYes, it acts as a protocol bridge enabling PROFIBUS-DP devices to communicate directly with Rockwell ControlLogix systems via DF1-over-Ethernet.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Does it support multiple PROFIBUS slaves?\u003c\/strong\u003e\u003cbr\u003eYes, it supports up to 125 PROFIBUS-DP slave devices per network segment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What configuration software is required?\u003c\/strong\u003e\u003cbr\u003eThe module is configured using ProSoft Configuration Builder (PCB) software.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Is the module suitable for harsh environments?\u003c\/strong\u003e\u003cbr\u003eYes, it is rated for industrial environments with extended temperature, vibration, and EMC compliance.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43290060685402,"sku":"5204-DFNT-PDPM","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/5204-DFNT-PDPM2.jpg?v=1777454688"},{"product_id":"prosoft-mvi56e-mcmxt-modbus-communication-module","title":"ProSoft MVI56E-MCMXT Modbus Communication Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ProSoft\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMVI56E-MCMXT\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-reliability Modbus communication interface designed for integration with Allen-Bradley ControlLogix platforms. Engineered for demanding operating environments, it enables seamless data exchange between PLC systems and Modbus RTU\/ASCII networks.\u003c\/p\u003e\n\u003cp\u003eAs part of the XT (Extreme Environment) product line, this module is built with extended temperature tolerance, conformal coating protection, and reinforced electrical isolation to ensure stable operation in harsh industrial conditions such as oil fields, mining operations, and power infrastructure.\u003c\/p\u003e\n\u003cp\u003eIt supports simultaneous Modbus Master and Slave functionality, allowing flexible network architecture without additional hardware.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCommunication Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProtocol Support: Modbus RTU and Modbus ASCII\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Modes: Master, Slave, or combined Master\/Slave\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSerial Interfaces: Dual isolated RS-232 \/ RS-422 \/ RS-485 ports\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBaud Rate Range: 110 bps to 115.2 kbps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNode Address Range: 1 to 247\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eMaster functionality supports configurable polling strategies and up to 325 commands per port, enabling high-density device communication.\u003c\/p\u003e\n\u003cp\u003eSlave functionality exposes up to 10,000 registers for external Modbus masters, supporting both integer and floating-point data formats.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eControlLogix Integration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eBackplane Communication: High-speed optimized data transfer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSlot Requirement: Single ControlLogix slot\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRack Support: Local or remote chassis configurations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBackplane Current Draw: 800 mA @ 5 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDesigned for native compatibility with Allen-Bradley ControlLogix processors without requiring additional bridging hardware.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHardware \u0026amp; Environmental Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +70°C (XT Series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e1500 V (ports to backplane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock Rating\u003c\/td\u003e\n\u003ctd\u003e30 G operational\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5–95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eConformal coating applied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDual-port Modbus communication architecture\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSimultaneous Master and Slave operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExtended register mapping capacity (up to 10,000 registers)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConformal coating for corrosive or high-humidity environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBuilt-in diagnostics and communication statistics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-speed backplane processing for real-time control applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTypical Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOil \u0026amp; gas production control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower generation monitoring and DCS integration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMining equipment communication networks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePipeline compressor station automation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHeavy industrial process control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Can the module operate as both Modbus Master and Slave at the same time?\u003c\/strong\u003e\u003cbr\u003eYes, it supports concurrent Master and Slave operation for flexible network design.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Is it suitable for extreme environments?\u003c\/strong\u003e\u003cbr\u003eYes, the XT series design supports -40°C to +70°C operation with conformal coating for harsh conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: How many Modbus registers are supported?\u003c\/strong\u003e\u003cbr\u003eUp to 10,000 user-definable registers can be mapped.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Does it require a dedicated ControlLogix slot?\u003c\/strong\u003e\u003cbr\u003eYes, the module occupies a single standard ControlLogix rack slot.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43290071335002,"sku":"MVI56E-MCMXT","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/MVI56E-MCMXT2.jpg?v=1777455054"},{"product_id":"prosoft-mvi56e-mnetc-modbus-tcp-controllogix-gateway-module","title":"ProSoft MVI56E-MNETC Modbus TCP ControlLogix Gateway Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ProSoft\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMVI56E-MNETC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an enhanced communication interface designed to connect Allen-Bradley ControlLogix platforms with Modbus TCP\/IP networks. It enables bidirectional data exchange between Ethernet-based industrial devices and PLC control systems without requiring protocol conversion hardware beyond the module itself.\u003c\/p\u003e\n\u003cp\u003eBuilt on the ProSoft E-Series architecture, the module is optimized for high-throughput applications, supporting simultaneous client and server communication with stable performance under heavy network loads.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCommunication Architecture\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eModbus TCP\/IP Interface\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProtocol: Modbus TCP\/IP over Ethernet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Modes: Client (Master), Server (Slave), or simultaneous operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEthernet Interface: 10\/100 Mbps, auto-negotiation, full\/half duplex\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnection Capacity:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eUp to 30 client sessions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUp to 10 server sessions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eSupported Functions:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRead\/Write Coils\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRead\/Write Holding Registers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInput Registers and Discrete Inputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eData Handling: Supports integer, floating-point, and bit-level mapping\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaximum Data Capacity: Up to 10,000 registers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eControlLogix Integration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eBackplane: High-speed optimized data transfer for ControlLogix chassis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSlot Requirement: Single standard ControlLogix slot\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfiguration Tool: ProSoft Configuration Builder (PCB)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDiagnostics Access: Embedded web server for live monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStatus Feedback: Ethernet, module, application, and backplane indicators\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eHardware \u0026amp; Environmental Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: -20°C to +60°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage Temperature: -40°C to +85°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower Consumption: \u0026lt; 5 W typical\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eElectrical Isolation: 1500 V (Ethernet to backplane)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHumidity Range: 5–95% non-condensing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVibration\/Shock: IEC 60068-2 compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRack Compatibility: Local or remote ControlLogix chassis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Engineering Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-performance Modbus TCP\/IP processing engine\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConcurrent client\/server communication architecture\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOptimized backplane bandwidth utilization\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBuilt-in web-based diagnostics and statistics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports redundant Ethernet network configurations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned for large-scale data exchange environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStable operation under continuous industrial load conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTypical Application Areas\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSCADA and distributed control system integration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower generation monitoring and control networks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOil \u0026amp; gas production and pipeline automation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWater and wastewater treatment systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eChemical and process manufacturing plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Can the module operate as both client and server at the same time?\u003c\/strong\u003e\u003cbr\u003eYes, it supports simultaneous Modbus TCP client and server operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What is the maximum number of connections supported?\u003c\/strong\u003e\u003cbr\u003eUp to 30 client and 10 server connections can run concurrently.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Does it support large data mapping?\u003c\/strong\u003e\u003cbr\u003eYes, it supports up to 10,000 Modbus registers with multiple data types.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Is it suitable for redundant Ethernet networks?\u003c\/strong\u003e\u003cbr\u003eYes, it is compatible with redundant network topologies used in ControlLogix systems.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43290072285274,"sku":"MVI56E-MNETC","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/MVI56E-MCMXT1.jpg?v=1777455054"},{"product_id":"prosoft-mvi69e-mbtcp-compactlogix-modbus-tcp-gateway-module","title":"ProSoft MVI69E-MBTCP CompactLogix Modbus TCP Gateway Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ProSoft\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMVI69E-MBTCP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a CompactLogix-compatible communication module that enables seamless Modbus TCP\/IP integration for Allen-Bradley 1769 platform controllers. It is engineered to bridge CompactLogix processors with external Modbus TCP devices such as field instruments, drives, analyzers, and distributed control systems.\u003c\/p\u003e\n\u003cp\u003eThis module belongs to the Enhanced (E-Series) architecture, providing improved processing throughput, expanded memory handling, and enhanced diagnostics compared to standard ProSoft communication modules.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCommunication Functions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eModbus TCP\/IP Interface\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProtocol: Modbus TCP\/IP over Ethernet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Modes: Client (Master), Server (Slave), or simultaneous operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEthernet Interface: 10\/100 Mbps auto-negotiation, full\/half duplex\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnection Capacity:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eUp to 30 client sessions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUp to 10 server sessions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eSupported Functions:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCoil read\/write operations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHolding register access\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInput register monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDiscrete input handling\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eData Handling Capacity: Up to 10,000 registers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eData Types: Integer, floating-point, and bit-level mapping supported\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCompactLogix Integration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePlatform: Allen-Bradley CompactLogix 1769 series\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSlot Requirement: One standard 1769 I\/O slot\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBackplane Communication: High-speed optimized data exchange\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfiguration Tool: ProSoft Configuration Builder (PCB)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDiagnostics Interface: Embedded web server for live system monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStatus Indicators: Ethernet activity, module health, application status, backplane communication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eHardware \u0026amp; Environmental Ratings\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: -20°C to +60°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage Temperature: -40°C to +85°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHumidity Range: 5–95% non-condensing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower Consumption: \u0026lt; 5 W typical\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eElectrical Isolation: 1500 V (Ethernet to backplane)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVibration\/Impact: IEC 60068-2 compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eModule Format: 1769 standard CompactLogix I\/O form factor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOptimized Modbus TCP\/IP engine for CompactLogix systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConcurrent client and server communication support\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-throughput backplane data transfer architecture\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBuilt-in web diagnostics and communication counters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge-scale register mapping capability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupport for redundant Ethernet network configurations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReduced configuration complexity via ProSoft tools\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eIndustrial Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSCADA and distributed monitoring systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWater and wastewater infrastructure control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOil \u0026amp; gas production and pipeline automation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower generation and utility monitoring systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eChemical processing and refinery networks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDiscrete and process manufacturing environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Can this module act as both Modbus client and server?\u003c\/strong\u003e\u003cbr\u003eYes, it supports simultaneous client and server operation within a single module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What CompactLogix systems are supported?\u003c\/strong\u003e\u003cbr\u003eIt is designed for Allen-Bradley 1769-based CompactLogix controllers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: How much data can it handle?\u003c\/strong\u003e\u003cbr\u003eUp to 10,000 Modbus registers with mixed data types including floating-point values.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Does it support remote diagnostics?\u003c\/strong\u003e\u003cbr\u003eYes, it includes a built-in web server for real-time diagnostics and monitoring.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43290072875098,"sku":"MVI69E-MBTCP","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/MVI69E-MBTCP2.jpg?v=1777456036"},{"product_id":"prosoft-mvi56e-mnet-modbus-tcp-controllogix-gateway-module","title":"ProSoft MVI56E-MNET Modbus TCP ControlLogix Gateway Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ProSoft\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMVI56E-MNET\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an Ethernet-based communication interface developed for Allen-Bradley ControlLogix platforms, enabling direct connectivity to Modbus TCP\/IP networks. It is engineered to allow PLC processors to exchange data with a wide variety of Modbus-compatible field devices such as controllers, drives, instrumentation systems, and remote I\/O stations.\u003c\/p\u003e\n\u003cp\u003eAs part of ProSoft’s Enhanced E-Series architecture, this module focuses on higher throughput, expanded memory handling, and improved system diagnostics compared to earlier generation modules.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCommunication Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eModbus TCP\/IP Interface\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProtocol Standard: Modbus TCP\/IP over Ethernet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Modes: Client (Master), Server (Slave), or simultaneous operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEthernet Interface: 10\/100 Mbps auto-negotiation, full\/half duplex\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnection Capacity:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eUp to 30 client sessions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUp to 10 server sessions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eSupported Function Codes:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCoil read\/write\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHolding register read\/write\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInput register access\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDiscrete input monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eData Capacity: Supports up to 10,000 registers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eData Types: Integer, floating-point, and bit-level mapping\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eControlLogix System Integration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePlatform Compatibility: Allen-Bradley ControlLogix\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSlot Requirement: Single standard ControlLogix slot\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBackplane Communication: High-speed optimized data transfer architecture\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfiguration Tool: ProSoft Configuration Builder (PCB)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDiagnostics Interface: Embedded web server for live monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStatus Indicators: Module health, Ethernet activity, application state, and backplane status\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical \u0026amp; Environmental Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current Load\u003c\/td\u003e\n\u003ctd\u003e800 mA @ 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary Supply\u003c\/td\u003e\n\u003ctd\u003e3 mA @ 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExtended Version\u003c\/td\u003e\n\u003ctd\u003e-25°C to 70°C (XT variant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to 85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5–95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd\u003e5 g (10–150 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock\u003c\/td\u003e\n\u003ctd\u003e30 g operational \/ 50 g non-operational\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Isolation\u003c\/td\u003e\n\u003ctd\u003e1500 V (Ethernet to backplane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-throughput Modbus TCP\/IP processing engine\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDual-mode client\/server communication support\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOptimized backplane bandwidth utilization\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge-scale data block handling up to 10,000 registers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBuilt-in web diagnostics for troubleshooting and monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupport for redundant Ethernet network architectures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStable operation under continuous industrial load conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTypical Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSCADA and distributed control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOil \u0026amp; gas production and pipeline monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower generation control and auxiliary systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWater and wastewater treatment facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eChemical and petrochemical processing plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eManufacturing automation networks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Can this module operate in both client and server modes simultaneously?\u003c\/strong\u003e\u003cbr\u003eYes, it supports concurrent Modbus TCP client and server operations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: How many devices can it communicate with?\u003c\/strong\u003e\u003cbr\u003eIt supports up to 30 client and 10 server connections simultaneously.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Is web-based diagnostics available?\u003c\/strong\u003e\u003cbr\u003eYes, it includes an embedded web server for real-time diagnostics and statistics.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Does it support large data handling?\u003c\/strong\u003e\u003cbr\u003eYes, it can manage up to 10,000 Modbus registers with multiple data formats.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43290082410586,"sku":"MVI56E-MNET","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/MVI56E-MNET2.jpg?v=1777456484"},{"product_id":"prosoft-mvi46-mcm-modbus-master-slave-for-allen-bradley-slc-500","title":"ProSoft MVI46-MCM Modbus Master\/Slave for Allen Bradley SLC 500","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eProSoft MVI46-MCM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a versatile communication module designed to integrate Modbus RTU and Modbus ASCII devices with Allen-Bradley SLC 500 PLC systems. Compatible with SLC 5\/02 and later processors, it facilitates reliable, deterministic data exchange between SLC processors and a broad range of Modbus-enabled devices including drives, meters, and remote I\/O.\u003c\/p\u003e\n\u003cp\u003eThis module is ideal for modernizing legacy systems, supporting both master and slave operations, and providing seamless integration into industrial environments that require robust Modbus communication.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual Serial Ports\u003c\/strong\u003e: Two fully isolated RS-232\/422\/485 serial ports, independently configurable for master or slave operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModbus Protocols Supported\u003c\/strong\u003e: Modbus RTU and Modbus ASCII, enabling broad compatibility with various devices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eData Handling\u003c\/strong\u003e: Capable of handling up to 5,000 registers, supports integer, floating-point, and bit-level data types.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e: Easily configured with ProSoft Configuration Builder (PCB).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e: Built-in LED indicators for module, backplane status, application status, and serial port activity, simplifying troubleshooting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSlot Compatibility\u003c\/strong\u003e: Single-slot module that fits any 1746 SLC 500 backplane, supporting both local and extended rack configurations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus Master\/Slave communication module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePlatform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley SLC 500 (1746)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackplane Data Transfer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOptimized for SLC processors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration Software\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProSoft Configuration Builder (PCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8,000-word data exchange database\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocols Supported\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus RTU, Modbus ASCII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMaster, Slave, Master + Slave simultaneously\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSerial Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 x Isolated RS-232\/422\/485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBaud Rates\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 to 115,200 bps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Registers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported Data Types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInteger, Floating-point, Bit-level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C to 85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 g operational, 50 g non-operational\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1500 V between serial ports and backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSlot Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 SLC 1746 slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLED Indicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModule status, Backplane status, Serial activity, Application status, Error LED status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eProSoft MVI46-MCM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis widely used in applications requiring seamless Modbus communication with SLC 500 systems. Common uses include:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOil \u0026amp; Gas\u003c\/strong\u003e: Wellhead control, pipeline monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWater Treatment\u003c\/strong\u003e: Remote monitoring and control of water systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Generation\u003c\/strong\u003e: Integration with power plant DCS and control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturing\u003c\/strong\u003e: Industrial network integration and automation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLegacy System Modernization\u003c\/strong\u003e: Ideal for upgrading legacy SLC systems with modern Modbus communication capabilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Can this module support both Modbus Master and Slave at the same time?\u003c\/strong\u003e\u003cbr\u003eYes, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eProSoft MVI46-MCM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports both Modbus Master and Slave communication modes simultaneously, allowing for flexible integration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: How many devices can I connect to this module?\u003c\/strong\u003e\u003cbr\u003eThe module can support up to 5,000 Modbus registers and allows communication with multiple Modbus devices, depending on your system’s configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What is the configuration process like?\u003c\/strong\u003e\u003cbr\u003eThe module is easily configured using the ProSoft Configuration Builder (PCB), a user-friendly software tool that simplifies setup and deployment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Can this module be used with older SLC 500 systems?\u003c\/strong\u003e\u003cbr\u003eYes, it is compatible with SLC 5\/02 processors and later models, making it ideal for upgrading older systems.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43290083950682,"sku":"MVI46-MCM","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/MVI46-MCM2.jpg?v=1777456831"},{"product_id":"prosoft-plx31-eip-mbs-ethernet-ip-gateway-module","title":"ProSoft PLX31-EIP-MBS EtherNet\/IP Gateway Module","description":"\u003csection\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePLX31-EIP-MBS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecommunication module is an industrial protocol gateway developed by ProSoft Technology for integrating EtherNet\/IP controllers with Modbus serial field devices. It enables reliable bidirectional communication between Rockwell Automation PLC platforms and Modbus RTU or ASCII networks in mixed-protocol automation environments.\u003c\/p\u003e\n\u003cp\u003eDesigned as a standalone DIN-rail device, the module supports flexible deployment in control cabinets, SCADA systems, OEM machinery, and retrofit modernization projects. The gateway combines EtherNet\/IP Scanner and Adapter functionality with configurable Modbus Master or Slave operation, simplifying communication between modern Ethernet architectures and legacy serial equipment.\u003c\/p\u003e\n\u003cp\u003eThe compact industrial housing, extended operating temperature range, and diagnostic capabilities make the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePLX31-EIP-MBS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esuitable for continuous operation in demanding industrial facilities.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eProSoft Technology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003ePLX31-EIP-MBS\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eEtherNet\/IP to Modbus Serial Gateway\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Interface\u003c\/td\u003e\n\u003ctd\u003e10\/100 Mbps RJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEtherNet\/IP Modes\u003c\/td\u003e\n\u003ctd\u003eScanner and Adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocol Support\u003c\/td\u003e\n\u003ctd\u003eEtherNet\/IP, Modbus RTU, Modbus ASCII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Interface\u003c\/td\u003e\n\u003ctd\u003eSelectable RS-232 \/ RS-485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModbus Modes\u003c\/td\u003e\n\u003ctd\u003eMaster or Slave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaud Rate\u003c\/td\u003e\n\u003ctd\u003e1,200 to 115,200 bps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum EtherNet\/IP Connections\u003c\/td\u003e\n\u003ctd\u003eUp to 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegister Mapping Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 4,000 Modbus registers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Mapping\u003c\/td\u003e\n\u003ctd\u003eUp to 10,000 words\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Time\u003c\/td\u003e\n\u003ctd\u003eApprox. 10–250 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e10–36 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Power Consumption\u003c\/td\u003e\n\u003ctd\u003eApproximately 3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Method\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Material\u003c\/td\u003e\n\u003ctd\u003eIndustrial metal housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Range\u003c\/td\u003e\n\u003ctd\u003e5–95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UL\/cUL, Class I Division 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance\u003c\/td\u003e\n\u003ctd\u003eRoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.99 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eCommunication Functions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe gateway provides protocol conversion between EtherNet\/IP and Modbus serial devices without requiring custom PLC programming. It supports deterministic polling structures and configurable data exchange tables for stable communication performance.\u003c\/p\u003e\n\u003cp\u003eSupported device integration includes:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eVariable frequency drives\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower meters and analyzers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRemote I\/O stations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTemperature controllers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProcess instrumentation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLegacy Modbus RTU equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eConfiguration and Diagnostics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eConfiguration is performed using ProSoft Configuration Builder software through Ethernet connectivity. Integrated diagnostic tools help maintenance personnel monitor communication quality and troubleshoot network issues.\u003c\/p\u003e\n\u003cp\u003eAvailable diagnostics include:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eModbus exception reporting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePacket statistics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCIP connection monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSerial communication status\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEthernet link diagnostics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eEtherNet\/IP to Modbus RTU\/ASCII protocol conversion\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSimultaneous industrial Ethernet and serial communication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFlexible Master and Slave operating modes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible with ControlLogix, CompactLogix, and Micro800 controllers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial DIN-rail installation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-speed data mapping for process applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBuilt-in communication diagnostics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned for continuous industrial operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTypical Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePLX31-EIP-MBS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003egateway is commonly installed in systems where Ethernet-based PLC platforms must communicate with existing Modbus serial infrastructure.\u003c\/p\u003e\n\u003cp\u003eTypical installations include:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWater and wastewater facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOil and gas processing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eManufacturing production lines\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower generation systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBuilding automation systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial retrofit projects\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eCan the PLX31-EIP-MBS operate as both Modbus Master and Slave?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eYes. The module supports configurable Master or Slave operation depending on the application requirements.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eWhich Allen-Bradley PLC families are compatible?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe gateway is commonly used with ControlLogix, CompactLogix, and Micro800 controllers through EtherNet\/IP communication.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDoes the module support both RS-232 and RS-485?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eYes. The serial interface can be configured for either RS-232 or RS-485 communication standards.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eIs the gateway suitable for industrial environments?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eYes. The unit is designed for industrial control panels and supports extended temperature operation, DIN-rail mounting, and Class I Division 2 certification.\u003c\/p\u003e\n\u003c\/section\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43404307988570,"sku":"PLX31-EIP-MBS","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/PLX31-EIP-MBS2.jpg?v=1779422231"},{"product_id":"prosoft-plx31-eip-mbs4-modbus-serial-gateway-module","title":"ProSoft PLX31-EIP-MBS4 Modbus Serial Gateway Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePLX31-EIP-MBS4\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom ProSoft Technology is an industrial communication gateway engineered to exchange data between EtherNet\/IP automation networks and multiple Modbus serial devices. The module belongs to the PLX31 series and provides four independently configurable serial channels for integrating legacy Modbus equipment into Rockwell Automation architectures.\u003c\/p\u003e\n\u003cp\u003eThis gateway is commonly deployed in applications where a single PLC must communicate with several isolated Modbus RTU or ASCII networks simultaneously. Its standalone DIN-rail design allows installation without occupying PLC rack space, making it suitable for both new automation systems and retrofit projects.\u003c\/p\u003e\n\u003cp\u003eThe module supports EtherNet\/IP Scanner and Adapter functionality together with Modbus Master or Slave operation, allowing flexible protocol conversion in distributed control environments.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eProSoft Technology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003ePLX31-EIP-MBS4\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Category\u003c\/td\u003e\n\u003ctd\u003eEtherNet\/IP to Modbus Serial Gateway\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEtherNet\/IP Interface\u003c\/td\u003e\n\u003ctd\u003e1 × RJ45, 10\/100 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEtherNet\/IP Modes\u003c\/td\u003e\n\u003ctd\u003eScanner and Adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported CIP Connections\u003c\/td\u003e\n\u003ctd\u003eUp to 10 simultaneous connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClass 3 Server Connections\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClass 1 I\/O Connections\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Connection Size\u003c\/td\u003e\n\u003ctd\u003e248 bytes input \/ 248 bytes output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum RPI\u003c\/td\u003e\n\u003ctd\u003e5 ms per connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Ports\u003c\/td\u003e\n\u003ctd\u003e4 independent RS-232\/RS-485 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModbus Protocols\u003c\/td\u003e\n\u003ctd\u003eModbus RTU and Modbus ASCII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModbus Modes\u003c\/td\u003e\n\u003ctd\u003eMaster or Slave selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaud Rate Range\u003c\/td\u003e\n\u003ctd\u003e1,200 to 115,200 bps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegister Mapping\u003c\/td\u003e\n\u003ctd\u003eUp to 4,000 registers per configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Mapping Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 10,000 words\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e10–36 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e300 mA typical @ 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current Load\u003c\/td\u003e\n\u003ctd\u003e610 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eIndustrial metal housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +80°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5–95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance\u003c\/td\u003e\n\u003ctd\u003eCE, UL\/cUL, RoHS, Class I Div 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.99 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eCommunication Architecture\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePLX31-EIP-MBS4\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eenables simultaneous communication between EtherNet\/IP controllers and multiple serial Modbus segments. Each serial channel can be configured independently for different baud rates, node addressing, and protocol modes.\u003c\/p\u003e\n\u003cp\u003eThe gateway supports communication with:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eVariable frequency drives\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower monitoring equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFlow analyzers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRemote terminal units\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLegacy PLC systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProcess instrumentation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDistributed I\/O devices\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eConfiguration and Diagnostics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSetup and maintenance are performed through ProSoft Configuration Builder software using Ethernet connectivity. The integrated web diagnostic interface provides live monitoring and troubleshooting tools for commissioning and maintenance personnel.\u003c\/p\u003e\n\u003cp\u003eDiagnostic functions include:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eEthernet communication statistics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eModbus exception reporting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSerial port activity monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCIP connection diagnostics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePacket error counters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnection health status\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eFour isolated Modbus serial communication channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEtherNet\/IP to Modbus RTU\/ASCII conversion\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndependent serial-port configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-speed cyclic data transfer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible with ControlLogix and CompactLogix systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAdd-On Profile support for simplified PLC integration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDIN-rail industrial installation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEmbedded diagnostic web server\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned for continuous industrial operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication Examples\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePLX31-EIP-MBS4\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis widely used in facilities requiring communication between Ethernet-based PLC platforms and multiple serial field networks.\u003c\/p\u003e\n\u003cp\u003eCommon applications include:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWater and wastewater treatment systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOil and gas process automation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eManufacturing production equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower generation facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSCADA integration projects\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial modernization programs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMulti-network Modbus aggregation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eHow many Modbus devices can the PLX31-EIP-MBS4 support?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe number depends on network configuration, polling rate, and baud speed. The four serial ports allow multiple Modbus segments to operate simultaneously.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCan each serial port use different communication settings?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eYes. Each serial interface can be independently configured for RS-232 or RS-485 operation, baud rate, and Modbus mode.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eWhich PLC platforms are compatible with this gateway?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module is commonly integrated with Rockwell Automation ControlLogix, CompactLogix, and Micro800 systems through EtherNet\/IP communication.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDoes the module require rack installation?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eNo. The gateway is a standalone DIN-rail device and operates independently from the PLC chassis.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43404324765786,"sku":"PLX31-EIP-MBS4","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/PLX31-EIP-MBS4.jpg?v=1779422465"},{"product_id":"prosoft-mvi56e-mnetcr-modbus-tcp-ip-multi-client-enhanced-communications-module","title":"ProSoft MVI56E-MNETCR Modbus TCP\/IP Multi-Client Enhanced Communications Module","description":"\u003cp\u003eConfigured for Modbus TCP\/IP multi-client communication in a remote chassis, the \u003cstrong\u003eProSoft MVI56E-MNETCR\u003c\/strong\u003e (\u003cstrong\u003eMVI56E-MNETCR\u003c\/strong\u003e communications module) provides Ethernet-based protocol communication with the host control system.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMVI56E-MNETCR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eProSoft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eModbus TCP\/IP Multi-Client Enhanced Communications Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eRemote Chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Interface\u003c\/td\u003e\n\u003ctd\u003eModbus TCP\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current Load\u003c\/td\u003e\n\u003ctd\u003e800 mA @ 5 VDC; 3 mA @ 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.53 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eBackplane current load: 800 mA @ 5 VDC; 3 mA @ 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eModbus TCP\/IP Multi-Client Communication\u003c\/h3\u003e\n\u003cp\u003eThe MVI56E-MNETCR provides a Modbus TCP\/IP network interface for multi-client communication through an Ethernet network. The module operates from the host chassis backplane and requires the specified 5 VDC and 24 VDC current loads.\u003c\/p\u003e\n\u003cp\u003eThe supplied data identifies the module for remote chassis installation. Therefore, chassis compatibility and available backplane current should be verified before installation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What backplane current does the MVI56E-MNETCR require?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The specified backplane current load is 800 mA at 5 VDC and 3 mA at 24 VDC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What operating temperature range is specified for this module?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The specified operating range is 0 deg C to 60 deg C.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the supplied data specify module dimensions?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No dimensional data is provided, so enclosure clearance should be verified against the applicable hardware documentation.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the module in the specified remote chassis position and verify mechanical seating before energizing the system.\u003c\/p\u003e\n\u003cp\u003eConfirm that the chassis backplane can supply the stated 5 VDC and 24 VDC current loads without exceeding its rated capacity.\u003c\/p\u003e\n\u003cp\u003eRoute Ethernet communication wiring separately from high-current switching conductors and other strong electromagnetic noise sources.\u003c\/p\u003e\n\u003cp\u003eUse appropriate shield termination practices where shielded communication cabling is specified by the network installation standard.\u003c\/p\u003e\n\u003cp\u003eVerify network addressing, Modbus TCP\/IP configuration, and client connection parameters before placing the communication interface into service.\u003c\/p\u003e\n\u003cp\u003eMaintain the specified 0 deg C to 60 deg C operating environment during normal operation.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43931735818330,"sku":"MVI56E-MNETCR","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/MVI56E-MNETCR2_3b42d4b9-2c24-43cc-8624-c5d0a33a491d.jpg?v=1787907737"},{"product_id":"prosoft-mvi56e-mcmr-modbus-communication-module","title":"ProSoft MVI56E-MCMR Modbus Communication Module","description":"\u003cp\u003eConfigured for Modbus master\/slave communication through a 10\/100BASE-T interface, the \u003cstrong\u003eProSoft MVI56E-MCMR\u003c\/strong\u003e (\u003cstrong\u003eMVI56E-MCMR\u003c\/strong\u003e Modbus Communication Module) provides protocol communication within a chassis-based control system.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMVI56E-MCMR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eProSoft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eModbus Communication Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Mode\u003c\/td\u003e\n\u003ctd\u003eModbus Master\/Slave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Interface\u003c\/td\u003e\n\u003ctd\u003e10\/100BASE-T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Connector\u003c\/td\u003e\n\u003ctd\u003eRJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Serial Communication Rate\u003c\/td\u003e\n\u003ctd\u003e115.2 kbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChassis Type\u003c\/td\u003e\n\u003ctd\u003eEnhanced chassis compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption at 5 VDC\u003c\/td\u003e\n\u003ctd\u003e800 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption at 24 VDC\u003c\/td\u003e\n\u003ctd\u003e3 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.15 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e4.0 W at 5 VDC, based on specified 800 mA current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProtocol Conversion and Network Interface\u003c\/h3\u003e\n\u003cp\u003eThe MVI56E-MCMR provides Modbus master and slave communication for data exchange between connected control devices. Ethernet connectivity uses a 10\/100BASE-T interface with an RJ45 connector. The specified communication rate reaches 115.2 kbit\/s for supported serial Modbus communication.\u003c\/p\u003e\n\u003cp\u003eThe module uses a chassis-based installation arrangement and is identified as an enhanced chassis-compatible communication module. Current requirements are specified separately for the 5 VDC and 24 VDC supply rails.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What Ethernet interface does the MVI56E-MCMR provide?\u003cbr\u003eA: The module provides a 10\/100BASE-T Ethernet interface through an RJ45 connector.\u003c\/p\u003e\n\u003cp\u003eQ: Does the MVI56E-MCMR support both Modbus master and slave operation?\u003cbr\u003eA: Yes. The supplied specifications identify the module as supporting Modbus master\/slave communication.\u003c\/p\u003e\n\u003cp\u003eQ: What are the specified module current requirements?\u003cbr\u003eA: The module is specified at 800 mA on the 5 VDC rail and 3 mA on the 24 VDC rail.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the module in the designated chassis position according to the applicable chassis installation procedure. Confirm that the chassis power supply can support the specified 5 VDC current requirement before energization.\u003c\/p\u003e\n\u003cp\u003eRoute Ethernet communication cables separately from high-current power conductors, motor leads, and switching circuits where practical. Use the specified RJ45 interface and suitable industrial Ethernet cabling for the installation environment.\u003c\/p\u003e\n\u003cp\u003eMaintain proper cable strain relief and connector seating during installation. Do not exceed the supported communication interface specifications or substitute wiring methods that conflict with the equipment installation documentation.\u003c\/p\u003e\n\u003cp\u003eFor shielded communication cabling, terminate and bond the shield according to the system grounding design and applicable site standards. Avoid creating unintended ground loops through multiple shield termination paths.\u003c\/p\u003e\n\u003cp\u003eVerify module seating, chassis connections, network link status, and Modbus communication parameters before placing the communication path into service. Firmware compatibility should also be verified against the host chassis and application configuration before any firmware update.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43931751612506,"sku":"MVI56E-MCMR","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/MVI56E-MCMR2.jpg?v=1787907469"},{"product_id":"prosoft-mvi56e-mnetr-modbus-tcp-ip-client-server-enhanced-communication-module","title":"ProSoft MVI56E-MNETR Modbus TCP\/IP Client\/Server Enhanced Communication Module","description":"\u003cp\u003eConfigured for Modbus TCP\/IP client and server communication in ControlLogix systems, the \u003cstrong\u003eProSoft MVI56E-MNETR\u003c\/strong\u003e (\u003cstrong\u003eMVI56E-MNETR\u003c\/strong\u003e Enhanced Communication Module) provides Ethernet data exchange through ladder logic data transfer. The module occupies one slot and uses a 10\/100 Mbps Ethernet interface.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMVI56E-MNETR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eProSoft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eModbus TCP\/IP Client\/Server Enhanced Communication Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eControlLogix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3.00 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eBackplane load: 800 mA at 5 VDC; 3 mA at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot Requirement\u003c\/td\u003e\n\u003ctd\u003e1 slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Type\u003c\/td\u003e\n\u003ctd\u003eRemote\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Transfer Type\u003c\/td\u003e\n\u003ctd\u003eLadder Logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Configuration\u003c\/td\u003e\n\u003ctd\u003e10\/100 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser-Definable Module Data Memory Mapping\u003c\/td\u003e\n\u003ctd\u003e5,000 registers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClient Connection Commands\u003c\/td\u003e\n\u003ctd\u003e100 maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock\u003c\/td\u003e\n\u003ctd\u003e30 g operational\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Function\u003c\/td\u003e\n\u003ctd\u003eModbus TCP\/IP Client\/Server\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Block Type\u003c\/td\u003e\n\u003ctd\u003eReduced Data Block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eModbus TCP\/IP Communication and ControlLogix Integration\u003c\/h3\u003e\n\u003cp\u003eThe MVI56E-MNETR provides Modbus TCP\/IP client and server functions through a ControlLogix backplane interface. Ladder logic transfers application data between the ControlLogix processor and module data areas.\u003c\/p\u003e\n\u003cp\u003eThe Ethernet interface supports 10\/100 Mbps operation for Modbus TCP\/IP communication. User-definable data memory mapping provides capacity for up to 5,000 registers.\u003c\/p\u003e\n\u003cp\u003eThe module supports up to 100 client connection commands. Therefore, application configuration must account for the required Modbus TCP\/IP connection structure and processor data mapping.\u003c\/p\u003e\n\u003cp\u003eThe specified backplane current load is 800 mA at 5 VDC, with an additional 3 mA at 24 VDC. Backplane power budgeting must include the module load together with all other installed modules.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How much ControlLogix rack space does the MVI56E-MNETR require?\u003cbr\u003eA: The module requires one ControlLogix slot and is specified for remote rack installation.\u003c\/p\u003e\n\u003cp\u003eQ: What Ethernet communication speed does the module support?\u003cbr\u003eA: The supplied specifications identify a 10\/100 Mbps Ethernet configuration for Modbus TCP\/IP communication.\u003c\/p\u003e\n\u003cp\u003eQ: What backplane current must be included in the rack power calculation?\u003cbr\u003eA: The specified backplane load is 800 mA at 5 VDC, with 3 mA at 24 VDC.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the module in an approved ControlLogix rack position with the backplane power budget verified before energization.\u003c\/p\u003e\n\u003cp\u003eConfirm that the rack configuration provides sufficient current capacity for the stated 5 VDC and 24 VDC module loads.\u003c\/p\u003e\n\u003cp\u003eUse Ethernet cabling and connectors suitable for the installed industrial environment and maintain physical separation from high-voltage or high-current conductors.\u003c\/p\u003e\n\u003cp\u003eRoute communication wiring separately from motor, contactor, transformer, and other high-noise circuits where practical.\u003c\/p\u003e\n\u003cp\u003eTerminate cable shields according to the installation standard and system grounding design. Avoid creating unintended ground loops through shield connections.\u003c\/p\u003e\n\u003cp\u003eVerify the Ethernet network configuration before enabling Modbus TCP\/IP client or server communications.\u003c\/p\u003e\n\u003cp\u003eConfirm ladder logic data mapping against the configured module memory addresses before placing the communication path into service.\u003c\/p\u003e\n\u003cp\u003eMaintain the specified operating temperature and non-condensing humidity range during normal operation.\u003c\/p\u003e\n\u003cp\u003eDuring commissioning, verify Modbus TCP\/IP connectivity, register mapping, client connection commands, and processor-to-module data transfer independently.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43931776909402,"sku":"MVI56E-MNETR","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/MVI56E-MNETR.jpg?v=1787907911"},{"product_id":"prosoft-technology-mvi56e-sie-enhanced-communication-module","title":"ProSoft Technology MVI56E-SIE Enhanced Communication Module","description":"\u003cp\u003eConfigured for Siemens S7 data exchange in an Ethernet environment, the \u003cstrong\u003eProSoft Technology MVI56E-SIE\u003c\/strong\u003e (\u003cstrong\u003eMVI56E-SIE\u003c\/strong\u003e Enhanced Communication Module) provides direct protocol communication between Allen-Bradley ControlLogix processors and Siemens industrial controllers using S7 Messaging over TCP\/IP.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMVI56E-SIE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eProSoft Technology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eEnhanced Communication Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlatform\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley ControlLogix, 1756 chassis-based\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.00 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e800 mA at 5 VDC; 3 mA at 24 VDC backplane load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eSiemens Industrial Ethernet Protocol, S7 Client and Server over TCP\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Port\u003c\/td\u003e\n\u003ctd\u003e1 x 10\/100 Mbps RJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Function\u003c\/td\u003e\n\u003ctd\u003eAuto-crossover detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration Interface\u003c\/td\u003e\n\u003ctd\u003eMini-USB or Ethernet via ProSoft Configuration Builder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClient Connections\u003c\/td\u003e\n\u003ctd\u003eUp to 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eServer Connections\u003c\/td\u003e\n\u003ctd\u003eUp to 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Memory Database\u003c\/td\u003e\n\u003ctd\u003eUp to 10,000 16-bit registers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSiemens Data Access\u003c\/td\u003e\n\u003ctd\u003eData Blocks (DB), Inputs (I), Outputs (Q), Flags\/Merkers (M)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Siemens Controllers\u003c\/td\u003e\n\u003ctd\u003eS7-200, S7-300, S7-400, S7-1200, S7-1500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Siemens Communication Cards\u003c\/td\u003e\n\u003ctd\u003eSiemens CP communication cards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eFront-panel 4-character scrolling LED display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Compatibility\u003c\/td\u003e\n\u003ctd\u003eSingle-slot 1756 ControlLogix backplane compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eRJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSiemens Industrial Ethernet Protocol Interface\u003c\/h3\u003e\n\u003cp\u003eThe MVI56E-SIE operates as either a Siemens S7 Client or Server over TCP\/IP Ethernet communication. It supports data exchange with Siemens S7-200, S7-300, S7-400, S7-1200, and S7-1500 controllers.\u003c\/p\u003e\n\u003cp\u003eThe module provides access to Siemens Data Blocks, Inputs, Outputs, and Flags\/Merkers through its internal memory database. The database supports up to 10,000 16-bit registers for application data handling.\u003c\/p\u003e\n\u003cp\u003eThe Ethernet interface provides one 10\/100 Mbps RJ45 connection with automatic crossover detection. Client and Server operating modes each support up to 20 connections according to the supplied specifications.\u003c\/p\u003e\n\u003cp\u003eThe module uses the ControlLogix 1756 backplane for processor-side data exchange. Its specified backplane current load is 800 mA at 5 VDC and 3 mA at 24 VDC.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the MVI56E-SIE communicate with Siemens S7 controllers directly?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The module supports Siemens S7 Client and Server communication over TCP\/IP with the listed Siemens controller families.\u003c\/p\u003e\n\u003cp\u003eQ: What Ethernet interface is provided by the module?\u003c\/p\u003e\n\u003cp\u003eA: The module provides one 10\/100 Mbps RJ45 Ethernet port with automatic crossover detection.\u003c\/p\u003e\n\u003cp\u003eQ: How should the module be handled during installation or replacement?\u003c\/p\u003e\n\u003cp\u003eA: Follow the ControlLogix chassis installation procedure and verify power isolation before inserting or removing the module. The supplied data does not specify a hot-swap rating.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the module in a compatible single-slot 1756 ControlLogix chassis according to the applicable chassis installation procedure.\u003c\/p\u003e\n\u003cp\u003eVerify the available backplane current capacity against the module load of 800 mA at 5 VDC and 3 mA at 24 VDC.\u003c\/p\u003e\n\u003cp\u003eConnect the RJ45 Ethernet interface using industrial Ethernet cabling suitable for the installation environment. Separate communication cabling from high-voltage and high-current power conductors to reduce electromagnetic interference.\u003c\/p\u003e\n\u003cp\u003eFor shielded Ethernet installations, terminate cable shields according to the plant grounding architecture and applicable installation standards. Avoid creating unintended ground loops through multiple shield termination points.\u003c\/p\u003e\n\u003cp\u003eBefore commissioning, verify the configured Siemens IP parameters, S7 communication role, connection assignments, and mapped database addresses.\u003c\/p\u003e\n\u003cp\u003eUse the front-panel scrolling LED display to check module status, network diagnostics, and reported error codes during startup and troubleshooting.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43931781824602,"sku":"MVI56E-SIE","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/MVI56E-SIE2.jpg?v=1787908155"},{"product_id":"prosoft-mvi56-ltq-limitorque-valve-network-interface-module","title":"ProSoft MVI56-LTQ Limitorque Valve Network Interface Module","description":"\u003cp\u003eConfigured for Limitorque valve actuator network communication in a ControlLogix platform, the \u003cstrong\u003eProSoft MVI56-LTQ\u003c\/strong\u003e (\u003cstrong\u003eMVI56-LTQ Limitorque Valve Network Interface Module\u003c\/strong\u003e) transfers valve data through Ladder Logic with configurable serial baud rates.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMVI56-LTQ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eProSoft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eAllen Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eLimitorque Valve Network Interface Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eControlLogix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.00 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e800 mA at 5 VDC; source graphic also specifies 3 mA at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot(s)\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Type\u003c\/td\u003e\n\u003ctd\u003eLocal or Remote\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Transfer Type\u003c\/td\u003e\n\u003ctd\u003eLadder Logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaud Rate\u003c\/td\u003e\n\u003ctd\u003e1200-38400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eActive Slaves\u003c\/td\u003e\n\u003ctd\u003e1-150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage and Transfer Capacity\u003c\/td\u003e\n\u003ctd\u003e150 valves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePolling Scheme\u003c\/td\u003e\n\u003ctd\u003eNetwork\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current Load\u003c\/td\u003e\n\u003ctd\u003e800 mA at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlatform\u003c\/td\u003e\n\u003ctd\u003eControlLogix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProtocol Conversion and Valve Network Interface\u003c\/h3\u003e\n\u003cp\u003eThe MVI56-LTQ provides network communication between a ControlLogix controller and Limitorque valve actuators. Ladder Logic supplies the ControlLogix-side data transfer mechanism.\u003c\/p\u003e\n\u003cp\u003eThe configured baud rate range is 1200 to 38400, supporting serial communication with connected valve network devices. The interface supports 1 to 150 active slaves and a storage and transfer capacity of 150 valves.\u003c\/p\u003e\n\u003cp\u003eNetwork polling determines communication sequencing between the module and connected valve devices. The module occupies one ControlLogix chassis slot and can operate in local or remote rack configurations.\u003c\/p\u003e\n\u003cp\u003eThe specified backplane current load is 800 mA at 5 VDC. The supplied source graphic additionally identifies 800 mA at 5.1 VDC and 3 mA at 24 VDC.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: How many ControlLogix chassis slots does the MVI56-LTQ occupy?\u003cbr\u003eA: The MVI56-LTQ occupies one ControlLogix chassis slot.\u003c\/p\u003e\n\u003cp\u003eQ: What baud rates are supported by the MVI56-LTQ?\u003cbr\u003eA: The supplied specifications identify a configurable baud rate range of 1200 to 38400.\u003c\/p\u003e\n\u003cp\u003eQ: How many active valve slaves can the module support?\u003cbr\u003eA: The specified active slave range is 1 to 150, with storage and transfer capacity for 150 valves.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the module in the designated ControlLogix chassis slot and verify mechanical engagement with the backplane connector before energizing the system.\u003c\/p\u003e\n\u003cp\u003eConfirm the rack configuration as local or remote according to the actual ControlLogix installation. Verify the module's backplane current requirement against the available chassis power budget.\u003c\/p\u003e\n\u003cp\u003eUse the communication wiring specified for the connected Limitorque valve network. Keep communication conductors separated from high-voltage power wiring and high-current switching conductors.\u003c\/p\u003e\n\u003cp\u003eTerminate cable shields according to the plant grounding standard and the communication network installation requirements. Avoid creating unintended ground loops through multiple shield termination points.\u003c\/p\u003e\n\u003cp\u003eVerify baud rate and other communication parameters at both the MVI56-LTQ and connected valve network devices before starting network polling.\u003c\/p\u003e\n\u003cp\u003eThe supplied documentation contains conflicting weight values of 3.00 lbs (1.36 kg) and 2.00 lbs. Verify the actual hardware weight against the applicable manufacturer documentation before mechanical load calculations.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43931792277594,"sku":"MVI56-LTQ","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/MVI56-LTQ.jpg?v=1787908325"},{"product_id":"prosoft-mvi56-mcmr-modbus-communication-module","title":"ProSoft MVI56-MCMR Modbus Communication Module","description":"\u003cp\u003eThe \u003cstrong\u003eProSoft MVI56-MCMR\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eMVI56-MCMR\u003c\/strong\u003e Modbus Communication Module, provides Modbus RTU and ASCII communication through a ControlLogix backplane interface.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMVI56-MCMR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eProSoft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eModbus Communication Module with Reduced Data Block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlatform\u003c\/td\u003e\n\u003ctd\u003eControlLogix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eModbus RTU \/ ASCII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFG Port\u003c\/td\u003e\n\u003ctd\u003eRJ45; DB-9M with supplied cable; RS-232 only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModbus RTU\u003c\/td\u003e\n\u003ctd\u003eBinary mode with CRC-16 error checking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModbus ASCII\u003c\/td\u003e\n\u003ctd\u003eASCII mode with LRC error checking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaud Rate\u003c\/td\u003e\n\u003ctd\u003e110 to 115K baud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStop Bits\u003c\/td\u003e\n\u003ctd\u003e1 or 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Size\u003c\/td\u003e\n\u003ctd\u003e7 or 8 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParity\u003c\/td\u003e\n\u003ctd\u003eNone, Even, or Odd\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTS Timing Delays\u003c\/td\u003e\n\u003ctd\u003e0 to 65535 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current Load\u003c\/td\u003e\n\u003ctd\u003e800 mA at 5 VDC; 3 mA at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock\u003c\/td\u003e\n\u003ctd\u003e30 g operational; 50 g non-operational\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd\u003e5 g from 10 Hz to 150 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFloating Point Data\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFloating Point Implementations\u003c\/td\u003e\n\u003ctd\u003eEnron, Daniel, and other configurable implementations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.40 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eNot specified in supplied data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified; backplane current load is 800 mA at 5 VDC and 3 mA at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Platform Compatibility\u003c\/td\u003e\n\u003ctd\u003eControlLogix; EtherNet\/IP and ControlNet system environments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProtocol Conversion and Serial Communication\u003c\/h3\u003e\n\u003cp\u003eThe MVI56-MCMR provides Modbus RTU and Modbus ASCII processing for ControlLogix-based automation architectures. Serial communication uses configurable baud rate, data size, parity, stop bits, and RTS timing delays.\u003c\/p\u003e\n\u003cp\u003eRTU transfers use binary data with CRC-16 error checking, while ASCII transfers use LRC error checking. Floating point data movement supports configurable Enron, Daniel, and other implementation formats.\u003c\/p\u003e\n\u003cp\u003eThe CFG port provides RS-232 communication through an RJ45 interface or DB-9M connection using the supplied cable. The specified configuration interface is RS-232 only.\u003c\/p\u003e\n\u003cp\u003eThe module uses a reduced data block architecture for exchanging Modbus data with the ControlLogix backplane. Backplane loading is specified as 800 mA at 5 VDC and 3 mA at 24 VDC.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What serial interface is provided through the CFG port?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The CFG port supports RS-232 only and uses an RJ45 connector or DB-9M connection with the supplied cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which Modbus operating modes are supported?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The module supports Modbus RTU with CRC-16 error checking and Modbus ASCII with LRC error checking.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the MVI56-MCMR support floating point data?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. Floating point data movement supports configurable Enron, Daniel, and other implementation formats.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the module in the specified ControlLogix chassis position and verify the backplane power budget before energizing the rack. Confirm that the available 5 VDC backplane capacity accommodates the specified 800 mA current load.\u003c\/p\u003e\n\u003cp\u003eRoute RS-232 communication wiring separately from high-voltage power conductors and high-current switching circuits. Maintain appropriate physical separation where parallel routing could introduce electromagnetic interference.\u003c\/p\u003e\n\u003cp\u003eUse shielded communication cable where required by the installation environment. Terminate cable shields according to the site grounding design, avoiding unintended ground loops between separately referenced equipment.\u003c\/p\u003e\n\u003cp\u003eVerify serial parameters at both communication endpoints before commissioning. Baud rate, data size, parity, stop bits, and RTS timing must match the connected Modbus equipment.\u003c\/p\u003e\n\u003cp\u003eProtect the module and communication cabling from condensation, excessive vibration, and temperatures outside the specified operating range. Confirm connector seating and cable strain relief before applying system power.\u003c\/p\u003e\n\u003cp\u003eDuring troubleshooting, verify the ControlLogix backplane connection, RS-232 wiring, serial configuration, Modbus mode, and error-checking method before modifying application data mappings.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43931801321562,"sku":"MVI56-MCMR","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/MVI56-MCMR2.jpg?v=1787908739"},{"product_id":"prosoft-mvi56-mnet-modbus-tcp-ip-interface-module","title":"ProSoft MVI56-MNET Modbus TCP\/IP Interface Module","description":"\u003cp\u003eConfigured for Modbus TCP\/IP communication in ControlLogix architectures, the \u003cstrong\u003eProSoft MVI56-MNET\u003c\/strong\u003e (\u003cstrong\u003eMVI56\u003c\/strong\u003e communication module) provides Ethernet data exchange between the network and ControlLogix backplane.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMVI56-MNET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eProSoft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eModbus TCP\/IP Interface Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eControlLogix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Protocol\u003c\/td\u003e\n\u003ctd\u003eTCP\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Port\u003c\/td\u003e\n\u003ctd\u003eEthernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Data Rate\u003c\/td\u003e\n\u003ctd\u003e10\/100 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current Load\u003c\/td\u003e\n\u003ctd\u003e800 mA at 5 VDC; 3 mA at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndependent Server Connections\u003c\/td\u003e\n\u003ctd\u003eUp to 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService Ports\u003c\/td\u003e\n\u003ctd\u003ePort 2000 Encapsulated; Port 502 MBAP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Memory Mapping\u003c\/td\u003e\n\u003ctd\u003eUp to 5000 16-bit registers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003eAPP, ERR, OK LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e4-character alphanumeric LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3.00 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock Resistance\u003c\/td\u003e\n\u003ctd\u003e30 G operational; 50 G non-operational\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Resistance\u003c\/td\u003e\n\u003ctd\u003e5 G from 10 Hz to 150 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eBackplane load: 800 mA at 5 VDC; 3 mA at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended RAM\u003c\/td\u003e\n\u003ctd\u003e256 MB recommended; 128 MB minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEthernet Communication and Protocol Handling\u003c\/h3\u003e\n\u003cp\u003eThe MVI56-MNET provides Ethernet communication using TCP\/IP networking and supports Modbus TCP\/IP data exchange. The module supports up to 10 independent server connections through Service Port 2000 and Service Port 502.\u003c\/p\u003e\n\u003cp\u003eData mapping accommodates up to 5000 16-bit registers, allowing process data to be exchanged between the Ethernet interface and ControlLogix application memory.\u003c\/p\u003e\n\u003cp\u003eThe Ethernet interface operates at 10\/100 Mbps. Communication status can be monitored through dedicated APP, ERR, and OK LED indicators, while the four-character display provides local diagnostic information.\u003c\/p\u003e\n\u003cp\u003eAs a ProSoft communication module, protocol conversion latency depends on network traffic, PLC scan execution, connection loading, and application data mapping. The supplied specifications do not define a fixed numerical latency value.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What backplane current does the MVI56-MNET require?\u003c\/p\u003e\n\u003cp\u003eA: The specified backplane current load is 800 mA at 5 VDC and 3 mA at 24 VDC.\u003c\/p\u003e\n\u003cp\u003eQ: How many independent server connections are supported?\u003c\/p\u003e\n\u003cp\u003eA: The module supports up to 10 independent server connections across Service Port 2000 and Service Port 502.\u003c\/p\u003e\n\u003cp\u003eQ: Does the supplied data specify hot-swapping capability?\u003c\/p\u003e\n\u003cp\u003eA: No explicit hot-swap specification is provided. Installation and removal should therefore follow the applicable ControlLogix chassis and module handling procedures.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the module in the designated ControlLogix chassis position and verify correct mechanical seating before energizing the system.\u003c\/li\u003e\n\u003cli\u003eConfirm the backplane power budget can accommodate the specified 800 mA at 5 VDC and 3 mA at 24 VDC load.\u003c\/li\u003e\n\u003cli\u003eUse an Ethernet cable suitable for the installed industrial environment and maintain physical separation from high-voltage or high-current conductors.\u003c\/li\u003e\n\u003cli\u003eRoute communication wiring away from motor power cables, contactor wiring, and other high-noise sources where practical.\u003c\/li\u003e\n\u003cli\u003eMaintain cable shielding and grounding according to the plant grounding architecture and applicable Ethernet installation practices.\u003c\/li\u003e\n\u003cli\u003eVerify Ethernet link configuration and network addressing before enabling Modbus TCP\/IP communication.\u003c\/li\u003e\n\u003cli\u003eConfirm Service Port 2000 and Service Port 502 assignments against the configured application before establishing client connections.\u003c\/li\u003e\n\u003cli\u003eCheck APP, ERR, and OK indicators during commissioning to identify module or application status conditions.\u003c\/li\u003e\n\u003cli\u003eUse the four-character display together with controller diagnostics when troubleshooting communication or configuration faults.\u003c\/li\u003e\n\u003cli\u003eDo not exceed the specified environmental limits of 0 deg C to 60 deg C operating temperature and 5% to 95% non-condensing humidity.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43931807547482,"sku":"MVI56-MNET","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/MVI56-MNET.jpg?v=1787908876"},{"product_id":"prosoft-technology-mvi56-pdpmv1-profibus-dpv1-master-network-interface-module","title":"ProSoft Technology MVI56-PDPMV1 PROFIBUS DPV1 Master Network Interface Module","description":"\u003cp\u003eConfigured for PROFIBUS DPV1 master communication in ControlLogix systems, the \u003cstrong\u003eProSoft Technology MVI56-PDPMV1\u003c\/strong\u003e (\u003cstrong\u003eMVI56-PDPMV1\u003c\/strong\u003e network interface module) exchanges cyclic and acyclic data with PROFIBUS DP slave devices through an isolated RS-485 interface.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMVI56-PDPMV1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eProSoft Technology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePROFIBUS DPV1 Master Network Interface Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlatform\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley ControlLogix, 1756 chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.50 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e800 mA @ 5 VDC; 3 mA @ 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROFIBUS Protocol\u003c\/td\u003e\n\u003ctd\u003ePROFIBUS DP-V0 \/ DP-V1 Master\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Slave Devices\u003c\/td\u003e\n\u003ctd\u003eUp to 125 nodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Baud Rates\u003c\/td\u003e\n\u003ctd\u003e9.6 kbps to 12 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum I\/O Data per Slave\u003c\/td\u003e\n\u003ctd\u003e244 Bytes Input \/ 244 Bytes Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal I\/O Data Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 7168 Bytes Input \/ 7168 Bytes Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Interface\u003c\/td\u003e\n\u003ctd\u003e9-pin D-sub female, galvanically isolated RS-485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChassis Occupancy\u003c\/td\u003e\n\u003ctd\u003eSingle slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration Software\u003c\/td\u003e\n\u003ctd\u003eProSoft Configuration Builder (PCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, cULus, ATEX Zone 2, DNV, RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProtocol Conversion and Galvanic Isolation\u003c\/h3\u003e\n\u003cp\u003eThe MVI56-PDPMV1 operates as a PROFIBUS DP master while exchanging module data asynchronously with the ControlLogix processor. PROFIBUS DP-V0 supports cyclic process data exchange, while DP-V1 provides acyclic messaging for diagnostics and device parameterization.\u003c\/p\u003e\n\u003cp\u003eThe PROFIBUS network uses a galvanically isolated RS-485 physical interface through the 9-pin D-sub connector. Therefore, field wiring should maintain appropriate PROFIBUS shielding, termination, and cable routing practices.\u003c\/p\u003e\n\u003cp\u003eThe module supports communication speeds from 9.6 kbps through 12 Mbps and can address up to 125 PROFIBUS slave nodes. Configuration files are stored in internal module memory, supporting configuration retention during module replacement.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How is the MVI56-PDPMV1 connected to the ControlLogix system?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The module occupies one slot in a standard 1756 ControlLogix chassis and exchanges data with the processor through the backplane.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What physical interface connects the module to PROFIBUS devices?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The module uses a 9-pin D-sub female connector with a galvanically isolated RS-485 PROFIBUS interface.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the module support both cyclic and acyclic PROFIBUS communication?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. PROFIBUS DP-V0 provides cyclic data exchange, while DP-V1 supports acyclic messaging for diagnostics and parameterization.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the module in a compatible 1756 ControlLogix chassis with power removed according to the applicable chassis installation procedure.\u003c\/p\u003e\n\u003cp\u003eConnect the PROFIBUS cable to the 9-pin D-sub interface and maintain the network polarity and termination arrangement specified for the PROFIBUS installation.\u003c\/p\u003e\n\u003cp\u003eRoute PROFIBUS communication cables separately from high-current power conductors, motor cables, and other high-noise wiring where practical.\u003c\/p\u003e\n\u003cp\u003eTerminate cable shields according to the PROFIBUS installation standard and site grounding architecture. Avoid creating unintended ground-current paths through shield connections.\u003c\/p\u003e\n\u003cp\u003eVerify the configured PROFIBUS baud rate, master parameters, slave addresses, and cyclic I\/O data lengths before commissioning.\u003c\/p\u003e\n\u003cp\u003eCheck module status, backplane status, and PROFIBUS communication LEDs after startup. Resolve physical-layer faults before troubleshooting application-level data exchange.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43931814395994,"sku":"MVI56-PDPMV1","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/MVI56-PDPMV12.jpg?v=1787909099"},{"product_id":"prosoft-mvi69e-mbs-modbus-serial-enhanced-communication-module","title":"ProSoft MVI69E-MBS Modbus Serial Enhanced Communication Module","description":"\u003cp\u003eConfigured for Modbus serial data exchange in CompactLogix systems, the \u003cstrong\u003eProSoft MVI69E-MBS\u003c\/strong\u003e (\u003cstrong\u003eMVI69E-MBS\u003c\/strong\u003e Modbus Serial Enhanced Communication Module) provides two RJ45 application serial ports and Ethernet-based configuration.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMVI69E-MBS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eProSoft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eNot specified in supplied data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eModbus Serial Communication Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eCompactLogix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Processors\u003c\/td\u003e\n\u003ctd\u003eCompactLogix L2, L3, and L4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.00 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard 1769 single-slot module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication Serial Ports\u003c\/td\u003e\n\u003ctd\u003e2 x RJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration Port\u003c\/td\u003e\n\u003ctd\u003e10\/100 Mbps Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Capacity\u003c\/td\u003e\n\u003ctd\u003e10,000 words\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommand Support\u003c\/td\u003e\n\u003ctd\u003e250 commands per port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Size\u003c\/td\u003e\n\u003ctd\u003e60 \/ 120 \/ 240 x 16-bit integers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModbus Modes\u003c\/td\u003e\n\u003ctd\u003eRTU with CRC-16; ASCII with LRC error checking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNode Address\u003c\/td\u003e\n\u003ctd\u003e1 to 247, software selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Altitude\u003c\/td\u003e\n\u003ctd\u003e1000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified in supplied data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration Software\u003c\/td\u003e\n\u003ctd\u003eProSoft Configuration Builder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eModbus Serial Protocol and Communication Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe MVI69E-MBS supports Modbus RTU and Modbus ASCII communication through its application serial interfaces.\u003c\/p\u003e\n\u003cp\u003eRTU communication uses binary data representation with CRC-16 error checking, while ASCII mode uses LRC error checking.\u003c\/p\u003e\n\u003cp\u003eEach configured slave port provides status information including error codes, communication counters, and port status.\u003c\/p\u003e\n\u003cp\u003eSoftware-selectable node addressing supports Modbus addresses from 1 through 247 for configured network devices.\u003c\/p\u003e\n\u003cp\u003eThe module provides up to 250 commands per port, with a stated data capacity of 10,000 words.\u003c\/p\u003e\n\u003cp\u003eThe Ethernet interface operates at 10\/100 Mbps and is specified as the configuration port.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which CompactLogix processors are compatible with the MVI69E-MBS?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The supplied specifications identify CompactLogix L2, L3, and L4 processors as compatible processor platforms.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which Modbus communication modes are supported?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The module supports Modbus RTU using CRC-16 error checking and Modbus ASCII using LRC error checking.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the supplied documentation specify module power consumption?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No power consumption value is provided in the supplied technical information, so no numerical value is assigned here.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the module in the specified 1769 single-slot CompactLogix position according to the controller hardware documentation.\u003c\/p\u003e\n\u003cp\u003eVerify processor compatibility before energizing the chassis and confirm that the module is mechanically seated correctly.\u003c\/p\u003e\n\u003cp\u003eRoute serial communication wiring separately from high-voltage conductors, motor cables, and high-current switching circuits.\u003c\/p\u003e\n\u003cp\u003eMaintain appropriate cable shielding and terminate shields according to the plant grounding architecture and the connected serial-device requirements.\u003c\/p\u003e\n\u003cp\u003eAvoid creating unintended ground loops through shield connections, especially where equipment receives power from separate distribution points.\u003c\/p\u003e\n\u003cp\u003eConfirm RJ45 connector assignments before connecting field devices because the application serial ports and Ethernet configuration port serve different functions.\u003c\/p\u003e\n\u003cp\u003eConfigure the Modbus node address, communication mode, commands, and data allocation using the applicable ProSoft configuration software.\u003c\/p\u003e\n\u003cp\u003eVerify RTU CRC-16 or ASCII LRC error handling during commissioning by checking the available status counters and error information.\u003c\/p\u003e\n\u003cp\u003eDo not exceed the stated operating temperature, storage temperature, humidity, or installation altitude limits.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43968662700122,"sku":"MVI69E-MBS","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/MVI69E-MBS2.jpg?v=1788148833"},{"product_id":"allen-bradley-mvi69l-mbs-compactlogix-communication-module","title":"Allen-Bradley MVI69L-MBS CompactLogix Communication Module","description":"\u003cp\u003eConfigured for serial data exchange in CompactLogix systems, the \u003cstrong\u003eAllen-Bradley MVI69L-MBS\u003c\/strong\u003e (\u003cstrong\u003eMVI69L-MBS\u003c\/strong\u003e communication module) provides RS-232, RS-485, or RS-422 connectivity with 240-word input and output data capacity.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMVI69L-MBS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eCommunication Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eCompactLogix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.06 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current Load\u003c\/td\u003e\n\u003ctd\u003e450 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Data Size\u003c\/td\u003e\n\u003ctd\u003e240 words\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Data Size\u003c\/td\u003e\n\u003ctd\u003e240 words\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003eRS-232, RS-485, RS-422\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Altitude\u003c\/td\u003e\n\u003ctd\u003e1000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eCompactLogix Backplane and Serial Communication\u003c\/h3\u003e\n\u003cp\u003eThe MVI69L-MBS exchanges application data through the CompactLogix backplane interface and provides serial communication connectivity. The module supports RS-232, RS-485, and RS-422 physical interfaces, allowing connection to compatible serial devices.\u003c\/p\u003e\n\u003cp\u003eThe configured data capacity is 240 input words and 240 output words. The specified backplane current load is 450 mA, which must be included when calculating CompactLogix chassis power loading.\u003c\/p\u003e\n\u003cp\u003eSerial interface selection depends on the connected equipment and wiring topology. RS-485 and RS-422 installations require appropriate differential-pair wiring and correct termination practices where applicable.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What serial interfaces are provided by the MVI69L-MBS?\u003c\/p\u003e\n\u003cp\u003eA: The module provides RS-232, RS-485, and RS-422 communication interfaces for compatible serial devices.\u003c\/p\u003e\n\u003cp\u003eQ: What is the specified backplane current load?\u003c\/p\u003e\n\u003cp\u003eA: The MVI69L-MBS has a specified backplane current load of 450 mA.\u003c\/p\u003e\n\u003cp\u003eQ: What data capacity is specified for the module?\u003c\/p\u003e\n\u003cp\u003eA: The module provides 240 words of input data and 240 words of output data.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the module in the designated CompactLogix chassis position according to the applicable hardware documentation.\u003c\/p\u003e\n\u003cp\u003eVerify that the chassis power budget accommodates the specified 450 mA backplane current load before installation.\u003c\/p\u003e\n\u003cp\u003eRoute serial communication cables separately from high-voltage power conductors, contactor wiring, and high-current switching circuits.\u003c\/p\u003e\n\u003cp\u003eUse shielded communication cable where required by the connected serial equipment, and terminate cable shields according to the system grounding design.\u003c\/p\u003e\n\u003cp\u003eFor RS-485 or RS-422 networks, maintain correct signal polarity and apply termination according to the communication network topology.\u003c\/p\u003e\n\u003cp\u003eDo not connect or disconnect field wiring while energized unless the installed hardware and system procedures explicitly permit such operation.\u003c\/p\u003e\n\u003cp\u003eConfirm the operating environment remains within 0 deg C to 60 deg C and 5% to 95% relative humidity, non-condensing.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43968892272730,"sku":"MVI69L-MBS","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/MVI69L-MBS.jpg?v=1788154648"},{"product_id":"prosoft-mvi94-mcm-modbus-master-slave-communication-module","title":"ProSoft MVI94-MCM Modbus Master\/Slave Communication Module","description":"\u003cp\u003eConfigured for Modbus master\/slave communication within the 1794 Flex I\/O system, the \u003cstrong\u003eProSoft MVI94-MCM\u003c\/strong\u003e (\u003cstrong\u003eMVI94-MCM\u003c\/strong\u003e Modbus Communication Module) provides serial protocol interfacing through dedicated configuration and application ports.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMVI94-MCM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eProSoft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eModbus Master\/Slave Communication Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003e1794 Flex I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Series\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley 1794 Flex I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eModbus communication module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eSingle-slot module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot Position\u003c\/td\u003e\n\u003ctd\u003eAny slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current\u003c\/td\u003e\n\u003ctd\u003e20 mA @ 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power Supply\u003c\/td\u003e\n\u003ctd\u003e12 to 24 VDC, 340 to 170 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration Port\u003c\/td\u003e\n\u003ctd\u003ePRT1, Mini-DIN, RS-232, hardware handshaking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication Port\u003c\/td\u003e\n\u003ctd\u003ePRT2, Mini-DIN, RS-232\/422\/485, jumper selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication Port Isolation\u003c\/td\u003e\n\u003ctd\u003e500 V optical isolation from backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Modbus Function Codes\u003c\/td\u003e\n\u003ctd\u003e1, 2, 3, 4, 5, 6, 15, 16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommand Capacity\u003c\/td\u003e\n\u003ctd\u003e100 commands per port maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegister Capacity\u003c\/td\u003e\n\u003ctd\u003e5000 maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnron Modbus Version\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Usage\u003c\/td\u003e\n\u003ctd\u003eUser definable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock\u003c\/td\u003e\n\u003ctd\u003e30 g operational\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e9.4 cm x 9.4 cm x 6.9 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.44 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLED Indicators\u003c\/td\u003e\n\u003ctd\u003eModule status, backplane transfer, application status, serial activity, error\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation\u003c\/td\u003e\n\u003ctd\u003eDictated by user program\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSerial Protocol Conversion and Port Isolation\u003c\/h3\u003e\n\u003cp\u003eThe MVI94-MCM provides separate configuration and application serial interfaces for Modbus communication management. PRT1 uses RS-232 with hardware handshaking for configuration functions.\u003c\/p\u003e\n\u003cp\u003ePRT2 supports RS-232, RS-422, and RS-485 through jumper selection for application-side serial communication. The application interface provides 500 V optical isolation from the Flex I\/O backplane.\u003c\/p\u003e\n\u003cp\u003eThe module supports Modbus function codes 1, 2, 3, 4, 5, 6, 15, and 16. Command processing supports up to 100 commands per port, while the register capacity is specified at 5000 maximum.\u003c\/p\u003e\n\u003cp\u003eThe module transfers data through the 1794 Flex I\/O backplane with a specified current load of 20 mA at 5 VDC. Therefore, backplane loading should be included when calculating the available FlexBus current budget.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Can the MVI94-MCM communicate using RS-485?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The PRT2 application port supports RS-232, RS-422, and RS-485 through jumper selection.\u003c\/p\u003e\n\u003cp\u003eQ: Is the application serial port isolated from the Flex I\/O backplane?\u003c\/p\u003e\n\u003cp\u003eA: Yes. PRT2 provides 500 V optical isolation between the application serial interface and the backplane.\u003c\/p\u003e\n\u003cp\u003eQ: What Modbus function codes are supported?\u003c\/p\u003e\n\u003cp\u003eA: The module supports function codes 1, 2, 3, 4, 5, 6, 15, and 16.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the MVI94-MCM in an available single-slot position within the compatible 1794 Flex I\/O assembly.\u003c\/p\u003e\n\u003cp\u003eVerify the selected PRT2 jumper configuration before connecting RS-232, RS-422, or RS-485 field wiring. Do not change interface selection while energized.\u003c\/p\u003e\n\u003cp\u003eRoute serial communication wiring separately from high-voltage power conductors and high-current switching circuits. Maintain appropriate physical separation where parallel routing could introduce electromagnetic interference.\u003c\/p\u003e\n\u003cp\u003eFor shielded serial cables, terminate shielding according to the plant grounding standard and avoid creating unintended ground loops. RS-485 installations should maintain correct polarity and termination practices for the connected network topology.\u003c\/p\u003e\n\u003cp\u003eVerify the external 12 to 24 VDC supply and calculated current requirement before energizing the module. Include the 20 mA at 5 VDC backplane load in the Flex I\/O power budget.\u003c\/p\u003e\n\u003cp\u003eConfirm module status, backplane transfer, application, serial activity, and error indicators during commissioning. Configuration parameters should correspond to the connected Modbus device addressing and serial interface settings.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43968898072666,"sku":"MVI94-MCM","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/MVI94-MCM2.jpg?v=1788155207"},{"product_id":"prosoft-technology-plx31-eip-mbtcp-ethernet-ip-to-modbus-tcp-ip-gateway","title":"ProSoft Technology PLX31-EIP-MBTCP EtherNet\/IP to Modbus TCP\/IP Gateway","description":"\u003cp\u003eConfigured for bidirectional protocol conversion between EtherNet\/IP and Modbus TCP\/IP networks, the \u003cstrong\u003eProSoft Technology PLX31-EIP-MBTCP\u003c\/strong\u003e (\u003cstrong\u003ePLX31-EIP-MBTCP\u003c\/strong\u003e communication gateway) provides direct Ethernet data exchange between industrial controllers and Modbus TCP\/IP devices.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePLX31-EIP-MBTCP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eProSoft Technology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.00 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-25 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC @ 200 mA; 10 to 30 VDC @ 400 mA max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e10 to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Ports\u003c\/td\u003e\n\u003ctd\u003e2 x RJ45, 10\/100 Mbps, Auto-MDI\/MDI-X, shared IP address\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocols\u003c\/td\u003e\n\u003ctd\u003eEtherNet\/IP and Modbus TCP\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eStandard 35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd\u003e5 g @ 10 to 150 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperational Shock\u003c\/td\u003e\n\u003ctd\u003e30 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eProSoft Configuration Builder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eController Integration\u003c\/td\u003e\n\u003ctd\u003eStudio 5000 \/ RSLogix 5000 AOP and AOI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Storage\u003c\/td\u003e\n\u003ctd\u003eSD card configuration backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Area Rating\u003c\/td\u003e\n\u003ctd\u003eUL\/cUL Class 1 Div. 2, ATEX Zone 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProtocol Conversion and Network Interface\u003c\/h3\u003e\n\u003cp\u003eThe PLX31-EIP-MBTCP exchanges mapped data between EtherNet\/IP controllers and Modbus TCP\/IP devices without custom ladder logic for protocol translation. Its two RJ45 Ethernet ports share one IP address, supporting network daisy-chaining while maintaining a single logical Ethernet interface.\u003c\/p\u003e\n\u003cp\u003eThe gateway supports EtherNet\/IP integration with Rockwell Automation ControlLogix and CompactLogix controllers through Add-On Profiles and Add-On Instructions. ProSoft Configuration Builder provides configuration and diagnostic functions, while the SD card supports local configuration backup for replacement procedures.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can both Ethernet ports use separate IP addresses?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. The supplied specifications identify both RJ45 ports as sharing a single IP address.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What DC supply range does the gateway accept?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The specified supply range is 10 to 30 VDC, with a maximum current load of 400 mA.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the gateway suitable for DIN-rail installation?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The specified mounting method is a standard 35 mm DIN rail.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the gateway securely on a standard 35 mm DIN rail inside an enclosure appropriate for the specified IP20 protection level.\u003c\/li\u003e\n\u003cli\u003eProvide a regulated DC supply within the specified 10 to 30 VDC operating range.\u003c\/li\u003e\n\u003cli\u003eSize the DC power wiring for the specified maximum current load and protect the supply according to the control-panel design.\u003c\/li\u003e\n\u003cli\u003eRoute Ethernet cables separately from high-voltage power wiring and high-current switching conductors where practical.\u003c\/li\u003e\n\u003cli\u003eUse shielded Ethernet cabling where the installation environment requires additional electromagnetic-noise control.\u003c\/li\u003e\n\u003cli\u003eBond cable shields according to the site's industrial grounding scheme and avoid unintended ground-current paths.\u003c\/li\u003e\n\u003cli\u003eVerify the shared-IP architecture before assigning the gateway address and connecting both Ethernet ports.\u003c\/li\u003e\n\u003cli\u003eBack up the gateway configuration to the SD card after commissioning and retain the configuration with the panel documentation.\u003c\/li\u003e\n\u003cli\u003eConfirm EtherNet\/IP controller mappings and Modbus TCP\/IP register mappings before placing the gateway into service.\u003c\/li\u003e\n\u003cli\u003eFor hazardous-area installations, verify that the complete installation satisfies the applicable UL\/cUL Class 1 Div. 2 or ATEX Zone 2 requirements.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43968913014874,"sku":"PLX31-EIP-MBTCP","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/PLX31-EIP-MBTCP2.jpg?v=1788155845"},{"product_id":"prosoft-technology-plx31-eip-pnd-ethernet-ip-to-profinet-gateway","title":"ProSoft Technology PLX31-EIP-PND EtherNet\/IP to PROFINET Gateway","description":"\u003cp\u003eConfigured for bidirectional data transfer between EtherNet\/IP and PROFINET RT networks, the \u003cstrong\u003eProSoft Technology PLX31-EIP-PND\u003c\/strong\u003e (\u003cstrong\u003ePLX31-EIP-PND\u003c\/strong\u003e communication gateway) provides isolated network interfaces for PLC data exchange.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePLX31-EIP-PND\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eProSoft Technology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eEtherNet\/IP to PROFINET Device Gateway\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.06 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-25 deg C to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to 80 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e130 mA typical at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e10 VDC to 36 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Input Load\u003c\/td\u003e\n\u003ctd\u003e610 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Ports\u003c\/td\u003e\n\u003ctd\u003e2 x RJ45, 10\/100 Base-T, auto-negotiating, Auto-MDIX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort Isolation\u003c\/td\u003e\n\u003ctd\u003eTwo electrically isolated Ethernet ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEtherNet\/IP I\/O Data\u003c\/td\u003e\n\u003ctd\u003eUp to 500 bytes input and 500 bytes output per connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEtherNet\/IP Connections\u003c\/td\u003e\n\u003ctd\u003eMultiple CIP I\/O connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROFINET Protocol\u003c\/td\u003e\n\u003ctd\u003ePROFINET RT Device, Version 2.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROFINET I\/O Data\u003c\/td\u003e\n\u003ctd\u003eUp to 1440 bytes input and 1440 bytes output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eStandard 35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock\u003c\/td\u003e\n\u003ctd\u003eIEC 60068-2-27, 15g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd\u003eIEC 60068-2-6, 5g, 10 to 150 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration Storage\u003c\/td\u003e\n\u003ctd\u003eSD card slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProtocol Conversion and Network Isolation\u003c\/h3\u003e\n\u003cp\u003eThe PLX31-EIP-PND operates as an EtherNet\/IP adapter or scanner while functioning as a PROFINET RT device. Data exchanged between both networks uses gateway-managed memory mapping rather than native protocol translation within either PLC.\u003c\/p\u003e\n\u003cp\u003eTwo RJ45 Ethernet interfaces provide electrical isolation between the EtherNet\/IP and PROFINET network segments. Therefore, each interface can remain connected to its respective subnet without directly combining the physical Ethernet segments.\u003c\/p\u003e\n\u003cp\u003eThe EtherNet\/IP interface supports multiple CIP I\/O connections with up to 500 bytes of input and output data per connection. The PROFINET interface supports up to 1440 bytes of input and output data.\u003c\/p\u003e\n\u003cp\u003eThe SD card interface stores configuration information for replacement procedures. A configured replacement unit can therefore restore stored configuration without requiring computer-based parameter entry.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Can the two Ethernet ports be connected to separate network segments?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The supplied specifications identify the two RJ45 ports as electrically isolated, with separate EtherNet\/IP and PROFINET network functions.\u003c\/p\u003e\n\u003cp\u003eQ: What power supply range does the gateway accept?\u003c\/p\u003e\n\u003cp\u003eA: The specified input range is 10 VDC to 36 VDC, with 24 VDC identified as the nominal supply voltage.\u003c\/p\u003e\n\u003cp\u003eQ: What are the maximum stated PROFINET I\/O data sizes?\u003c\/p\u003e\n\u003cp\u003eA: The supplied specifications state up to 1440 bytes of input data and 1440 bytes of output data.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the gateway on a standard 35 mm DIN rail inside a suitable industrial control enclosure.\u003c\/li\u003e\n\u003cli\u003eVerify the DC supply polarity and confirm that the applied voltage remains within the specified 10 VDC to 36 VDC range.\u003c\/li\u003e\n\u003cli\u003eConnect the EtherNet\/IP and PROFINET cables to their designated isolated RJ45 ports.\u003c\/li\u003e\n\u003cli\u003eMaintain physical separation between network wiring and high-current motor, contactor, and switching-power conductors.\u003c\/li\u003e\n\u003cli\u003eUse shielded Ethernet cabling where required by the installed network design and terminate shields according to the applicable panel grounding scheme.\u003c\/li\u003e\n\u003cli\u003eAvoid creating unintended shield-to-ground paths between separately isolated network segments.\u003c\/li\u003e\n\u003cli\u003eVerify link speed, duplex negotiation, IP addressing, and controller-side protocol configuration before enabling cyclic I\/O exchange.\u003c\/li\u003e\n\u003cli\u003eRetain the configured SD card with the equipment documentation when using the configuration-recovery function.\u003c\/li\u003e\n\u003cli\u003eConfirm the gateway's operating temperature and vibration environment against the specified limits before installation.\u003c\/li\u003e\n\u003cli\u003eAfter commissioning, verify input and output data mapping independently from both the EtherNet\/IP and PROFINET controllers.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43968981893210,"sku":"PLX31-EIP-PND","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/PLX31-EIP-PND2.jpg?v=1788157752"},{"product_id":"prosoft-technology-plx32-eip-mbtcp-ethernet-ip-to-modbus-tcp-ip-gateway","title":"ProSoft Technology PLX32-EIP-MBTCP EtherNet\/IP to Modbus TCP\/IP Gateway","description":"\u003cp\u003eConfigured for protocol conversion between EtherNet\/IP and Modbus TCP\/IP networks, the \u003cstrong\u003eProSoft Technology PLX32-EIP-MBTCP\u003c\/strong\u003e (\u003cstrong\u003ePLX32-EIP-MBTCP\u003c\/strong\u003e protocol gateway) provides direct data exchange between industrial Ethernet devices without custom controller code.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePLX32-EIP-MBTCP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eProSoft Technology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.00 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-25 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e300 mA at 24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e10 to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Range\u003c\/td\u003e\n\u003ctd\u003e10 to 36 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Ports\u003c\/td\u003e\n\u003ctd\u003e2 x 10\/100 Mbps RJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Function\u003c\/td\u003e\n\u003ctd\u003eDual-port Ethernet switch functionality\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEtherNet\/IP Modes\u003c\/td\u003e\n\u003ctd\u003eExplicit Messaging Client\/Server; Implicit Messaging Class 1 I\/O Client\/Server\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEtherNet\/IP I\/O Data\u003c\/td\u003e\n\u003ctd\u003eUp to 500 bytes input and 500 bytes output per connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEtherNet\/IP Connections\u003c\/td\u003e\n\u003ctd\u003eUp to 16 CIP connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModbus TCP\/IP Modes\u003c\/td\u003e\n\u003ctd\u003eClient (Master) and Server (Slave)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModbus Functions\u003c\/td\u003e\n\u003ctd\u003e1, 2, 3, 4, 5, 6, 15, 16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModbus Client Connections\u003c\/td\u003e\n\u003ctd\u003eUp to 30 active connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModbus Server Connections\u003c\/td\u003e\n\u003ctd\u003eUp to 20 concurrent connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProtocol Conversion and Ethernet Architecture\u003c\/h3\u003e\n\u003cp\u003eThe PLX32-EIP-MBTCP provides EtherNet\/IP and Modbus TCP\/IP protocol interfaces within one hardware gateway.\u003c\/p\u003e\n\u003cp\u003eEtherNet\/IP operation supports both explicit messaging and Class 1 implicit I\/O communication.\u003c\/p\u003e\n\u003cp\u003eThe gateway supports up to 16 CIP connections for EtherNet\/IP data exchange.\u003c\/p\u003e\n\u003cp\u003eModbus TCP\/IP operation supports client and server modes, with simultaneous communication to multiple Modbus devices.\u003c\/p\u003e\n\u003cp\u003eThe two 10\/100 Mbps RJ45 ports provide dual-port Ethernet switch functionality for daisy-chain topologies or separate network connections.\u003c\/p\u003e\n\u003cp\u003eProtocol mapping should maintain consistent data types, register addresses, byte ordering, and connection assignments between both networks.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What EtherNet\/IP data capacity does the PLX32-EIP-MBTCP support?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Each connection supports up to 500 bytes of input data and 500 bytes of output data.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many Modbus TCP\/IP devices can the gateway communicate with as a client?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The gateway supports up to 30 active Modbus TCP\/IP client connections for simultaneous device queries.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What supply voltage range is specified for the module?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The supplied specifications identify a 10 to 30 VDC input voltage and a 10 to 36 VDC input range.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the gateway on a suitable industrial mounting surface with sufficient clearance for RJ45 connectors and power wiring.\u003c\/p\u003e\n\u003cp\u003eUse shielded Ethernet cabling where required by the surrounding electromagnetic environment and network installation standard.\u003c\/p\u003e\n\u003cp\u003eRoute Ethernet communication cables separately from high-current power conductors, motor cables, and high-frequency switching circuits.\u003c\/p\u003e\n\u003cp\u003eTerminate cable shields according to the plant grounding architecture and the applicable Ethernet installation requirements.\u003c\/p\u003e\n\u003cp\u003eVerify the DC supply polarity before energizing the module, and maintain the specified input voltage range.\u003c\/p\u003e\n\u003cp\u003eFor daisy-chain installations, verify Ethernet switch topology and cable routing before commissioning.\u003c\/p\u003e\n\u003cp\u003eConfigure EtherNet\/IP connection parameters, Modbus TCP\/IP addresses, register mappings, and communication modes consistently with the connected controllers and field devices.\u003c\/p\u003e\n\u003cp\u003eConfirm data types, register offsets, byte ordering, and read\/write permissions during commissioning before enabling process data exchange.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43969041498202,"sku":"PLX32-EIP-MBTCP","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/PLX32-EIP-MBTCP2.jpg?v=1788158941"},{"product_id":"prosoft-technology-plx82-eip-pnc-ethernet-ip-to-profinet-controller-gateway","title":"ProSoft Technology PLX82-EIP-PNC EtherNet\/IP to PROFINET Controller Gateway","description":"\u003cp\u003eConfigured for bi-directional protocol conversion between EtherNet\/IP controllers and PROFINET RT devices, the \u003cstrong\u003eProSoft Technology PLX82-EIP-PNC\u003c\/strong\u003e (\u003cstrong\u003ePLX82-EIP-PNC\u003c\/strong\u003e gateway) provides direct network-level data exchange between the two industrial Ethernet protocols.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePLX82-EIP-PNC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eProSoft Technology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eNot specified in supplied data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eEtherNet\/IP to PROFINET Controller Gateways\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3.10 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e14.01 cm x 5.24 cm x 11.09 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e400 mA at 24 VDC nominal; 610 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal; 10 to 36 VDC allowed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Ports\u003c\/td\u003e\n\u003ctd\u003e2 x 10\/100 Mbps RJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Isolation\u003c\/td\u003e\n\u003ctd\u003e1500 Vrms at 50 to 60 Hz for 60 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEtherNet\/IP Connections\u003c\/td\u003e\n\u003ctd\u003eClass 1 I\/O: up to 20; Class 3 Server: 5; Class 3 Client: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEtherNet\/IP I\/O Data\u003c\/td\u003e\n\u003ctd\u003e248 bytes input \/ 248 bytes output per connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum RPI\u003c\/td\u003e\n\u003ctd\u003e2 ms for 1 connection; 8 ms for 8 connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROFINET Role\u003c\/td\u003e\n\u003ctd\u003eClass 1 RTC \/ Class 1 RTA IO Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum PROFINET Devices\u003c\/td\u003e\n\u003ctd\u003eUp to 36 devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROFINET I\/O Data\u003c\/td\u003e\n\u003ctd\u003eUp to 1440 bytes in\/out per device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal PROFINET I\/O Data\u003c\/td\u003e\n\u003ctd\u003e3840 bytes IN \/ 3840 bytes OUT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 deg C to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eStandard 35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProtocol Conversion and Network Isolation\u003c\/h3\u003e\n\u003cp\u003eThe PLX82-EIP-PNC operates as an EtherNet\/IP adapter and a PROFINET IO Controller. It supports bi-directional exchange between EtherNet\/IP PLC systems and PROFINET RT field devices.\u003c\/p\u003e\n\u003cp\u003eTwo isolated Ethernet ports separate EtherNet\/IP and PROFINET network traffic onto independent physical interfaces and subnets. The specified electrical isolation rating is 1500 Vrms at 50 to 60 Hz for 60 seconds.\u003c\/p\u003e\n\u003cp\u003eEmbedded Add-On Profiles and EDS files support configuration within Studio 5000 and RSLogix 5000 environments. An onboard SD card provides configuration storage for replacement and recovery procedures.\u003c\/p\u003e\n\u003cp\u003eThe gateway supports up to 36 PROFINET devices, with a total PROFINET data capacity of 3840 bytes input and 3840 bytes output.\u003c\/p\u003e\n\u003cp\u003eProtocol conversion latency depends on the configured EtherNet\/IP connection count and requested packet interval. The supplied specifications state a minimum RPI of 2 ms for one connection and 8 ms for eight connections.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the PLX82-EIP-PNC directly control PROFINET RT devices from an EtherNet\/IP PLC?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The gateway functions as a PROFINET Class 1 IO Controller while communicating with the EtherNet\/IP PLC as an EtherNet\/IP adapter.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many PROFINET devices can the gateway manage?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The supplied specification permits up to 36 PROFINET devices, with up to 1440 bytes of input and output data per device.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What mounting arrangement is specified for field installation?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The unit is specified for standard 35 mm DIN-rail mounting. Maintain adequate wiring clearance around both Ethernet interfaces and the power terminals.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the gateway on a mechanically secure 35 mm DIN rail within the specified operating temperature and humidity limits.\u003c\/p\u003e\n\u003cp\u003eConnect the 24 VDC supply within the stated 10 to 36 VDC input range, observing correct polarity and protective grounding requirements.\u003c\/p\u003e\n\u003cp\u003eRoute EtherNet\/IP and PROFINET cables separately where practical, particularly from high-current switching conductors, motor cables, and other high-noise sources.\u003c\/p\u003e\n\u003cp\u003eUse shielded industrial Ethernet cabling where the network design requires electromagnetic noise control. Terminate cable shields according to the plant grounding scheme and avoid uncontrolled multiple-point shield connections.\u003c\/p\u003e\n\u003cp\u003eAssign the two Ethernet interfaces to their intended network segments. Verify IP addressing, subnet configuration, EtherNet\/IP connection parameters, and PROFINET device configuration before placing the gateway into service.\u003c\/p\u003e\n\u003cp\u003eUse the SD card for configuration backup and controlled replacement procedures. Confirm that stored configuration data matches the installed hardware and network topology before recovery.\u003c\/p\u003e\n\u003cp\u003eDo not exceed the specified EtherNet\/IP connection limits, PROFINET device count, or I\/O data capacities during configuration.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43969064173658,"sku":"PLX82-EIP-PNC","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/PLX82-EIP-PNC2.jpg?v=1788159745"},{"product_id":"prosoft-mvi56-bas-controllogix-basic-communication-module","title":"ProSoft MVI56-BAS ControlLogix BASIC Communication Module","description":"\u003cp\u003eConfigured for custom programmable ASCII processing and serial communication interface handling in Allen-Bradley ControlLogix backplanes, the \u003cstrong\u003eProSoft MVI56-BAS\u003c\/strong\u003e (\u003cstrong\u003eMVI56-BAS\u003c\/strong\u003e BASIC Communication Module) provides direct physical\/electrical execution. The module enables customized BASIC-52 programming algorithms to execute locally within a single ControlLogix chassis slot, processing data directly to and from the controller processor memory via ladder logic data transfer routines across local or remote chassis racks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMVI56-BAS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eProSoft Technology \/ Allen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.68 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e4.0 W (800 mA at 5 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current Load\u003c\/td\u003e\n\u003ctd\u003e800 mA at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot Requirement\u003c\/td\u003e\n\u003ctd\u003e1 slot (ControlLogix local or remote rack)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRAM Memory\u003c\/td\u003e\n\u003ctd\u003e24064 bytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Transfer Type\u003c\/td\u003e\n\u003ctd\u003eLadder Logic Data Transfer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgramming Language\u003c\/td\u003e\n\u003ctd\u003eBASIC-52\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgram Backup\u003c\/td\u003e\n\u003ctd\u003eEasy BASIC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperational Shock\u003c\/td\u003e\n\u003ctd\u003e30G Operational\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProtocol Conversion Latencies and Backplane Bus Synchronization\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eProSoft MVI56-BAS\u003c\/strong\u003e utilizes an onboard microprocessor executing compiled BASIC-52 routines independent of the main ControlLogix CPU cycle. Protocol conversion latencies are minimized by establishing dual-port RAM buffers that interface directly with the ControlLogix backplane driver. Data transfers between the module's 24064-byte RAM allocation and the Programmable Automation Controller (PAC) are controlled via standardized ladder logic block transfers. This decoupled architecture isolates legacy serial devices, custom ASCII barcode scanners, and proprietary serial protocols from degrading backplane bus communication velocity. Onboard surge protection network barriers on the serial interface channels enforce galvanic isolation across connected field instrumentation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the MVI56-BAS module be removed or inserted while the ControlLogix chassis is powered?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module supports Removal and Insertion Under Power (RIUP). However, to prevent data corruption in active registers, control logic communication blocks should be disabled prior to physical extraction.\u003c\/p\u003e\n\u003cp\u003eQ: How is the 24064 bytes RAM program memory protected against power failure?\u003c\/p\u003e\n\u003cp\u003eA: Program code and system parameters stored in module memory rely on the Easy BASIC non-volatile backup architecture, preserving execution scripts across complete power loss cycles without requiring continuous backplane power.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003ePower down the ControlLogix rack or verify that local hazardous location conditions permit Removal and Insertion Under Power (RIUP) operation before installation.\u003c\/li\u003e\n\u003cli\u003eAlign the module circuit board with the top and bottom chassis card guides of the selected slot in the local or remote chassis.\u003c\/li\u003e\n\u003cli\u003eSlide the module firmly into the slot until the top and bottom retaining tabs click securely into place on the chassis rail.\u003c\/li\u003e\n\u003cli\u003eConnect serial field cabling to the front panel communication interface, maintaining shielded twisted-pair wire routing separated from high-voltage AC motor control lines by at least 300 mm.\u003c\/li\u003e\n\u003cli\u003eTerminate all cable shields at a single point grounding bus on the chassis enclosure earth point to prevent ground loops and high-frequency noise interference.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43996918579290,"sku":"MVI56-BAS","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/MVI56-BAS2.jpg?v=1788343372"},{"product_id":"prosoft-mvi69e-mbs-a-modbus-serial-modkit-communication-module","title":"ProSoft MVI69E-MBS\/A Modbus Serial Modkit Communication Module","description":"\u003cp\u003eThe \u003cstrong\u003eProSoft MVI69E-MBS\/A\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eMVI69E-MBS\/A\u003c\/strong\u003e Modbus Serial Enhanced Communication Module, operates as a dedicated hardware component for serial protocol interfacing within Rockwell Automation CompactLogix backplane platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMVI69E-MBS\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eProSoft Technology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.00 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eSingle-Slot CompactLogix Module Form Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C (32 to 140 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e2.5 W (500 mA @ 5 VDC backplane current load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eRockwell Automation CompactLogix L1, L2, L3, and L4 Controllers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003e2 x RS-232 \/ RS-422 \/ RS-485 serial ports (RJ45 connectors)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Port\u003c\/td\u003e\n\u003ctd\u003e1 x 10\/100 Mbps RJ45 port for configuration and diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Protocols\u003c\/td\u003e\n\u003ctd\u003eModbus RTU Master\/Slave, Modbus ASCII Master\/Slave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaud Rates\u003c\/td\u003e\n\u003ctd\u003e110 bps to 115.2 kbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDatabase Capacity\u003c\/td\u003e\n\u003ctd\u003e10,000 words internal shared memory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommand List Limit\u003c\/td\u003e\n\u003ctd\u003eUp to 250 commands per serial port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProtocol Conversion Latencies and DIN-Rail Stability\u003c\/h3\u003e\n\u003cp\u003eEngineered with low protocol conversion latencies, the module transfers data between Modbus serial field networks and the CompactLogix controller across a internal 10,000-word memory database. Built to maintain DIN-rail mounting stability under industrial vibration profiles, the hardware features integrated backplane connectors that lock firmly into the I\/O bus chassis, preventing transient signal loss across its 5 VDC power rails and internal serial transceivers.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the primary operational difference between serial ports 1 and 2 on the module?\u003c\/p\u003e\n\u003cp\u003eA: Ports 1 and 2 feature independent hardware transceivers, allowing each port to run under separate baud rates (110 bps to 115.2 kbps), different physical standards (RS-232\/422\/485), and distinct operational modes (Master vs. Slave).\u003c\/p\u003e\n\u003cp\u003eQ: Can the MVI69E-MBS\/A module be hot-swapped while the CompactLogix controller is powered?\u003c\/p\u003e\n\u003cp\u003eA: Module removal or insertion must occur while the rack power is turned off, unless the CompactLogix chassis explicitly supports Removal and Insertion Under Power (RIUP) and local electrical safety guidelines for non-hazardous locations are maintained.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhysical Mounting\u003c\/strong\u003e: Power down the CompactLogix rack before installation. Align the module with the DIN-rail slots, push firmly into the adjacent I\/O module or controller base, and engage the locking levers to ensure full backplane connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial Cable Grounding\u003c\/strong\u003e: Use high-quality shielded twisted-pair (STP) cabling for RS-485 or RS-422 signal lines. Drain wires must be grounded at a single chassis ground point to avoid circulating ground loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBus Termination\u003c\/strong\u003e: Ensure 120 ohm line termination resistors are connected at both physical ends of an RS-485 network trunk to minimize signal reflections over long cable runs.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":44006046105690,"sku":"MVI69E-MBS\/A","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/MVI69E-MBS1.jpg?v=1788148832"},{"product_id":"prosoft-technology-mvi69e-mbtcp-a-compactlogix-1769-modbus-tcp-ip-enhanced-communication-module","title":"ProSoft Technology MVI69E-MBTCP\/A CompactLogix 1769 Modbus TCP\/IP Enhanced Communication Module","description":"\u003cp\u003eConfigured for offloading Modbus TCP\/IP network protocol handling in Allen-Bradley 1769 CompactLogix architectures, the \u003cstrong\u003eProSoft Technology MVI69E-MBTCP\/A\u003c\/strong\u003e (\u003cstrong\u003eMVI69E-MBTCP\u003c\/strong\u003e Modbus TCP\/IP Enhanced Communication Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMVI69E-MBTCP\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eProSoft Technology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e2.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current Load\u003c\/td\u003e\n\u003ctd\u003e500 mA @ 5 VDC max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Distance Rating\u003c\/td\u003e\n\u003ctd\u003e4 slots\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003e1 x 10\/100 Mbps RJ45 Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocols Supported\u003c\/td\u003e\n\u003ctd\u003eModbus TCP\/IP Client \/ Server\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Client Connections\u003c\/td\u003e\n\u003ctd\u003e20 simultaneous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Server Connections\u003c\/td\u003e\n\u003ctd\u003e20 simultaneous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Database Memory\u003c\/td\u003e\n\u003ctd\u003e10000 words\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDedicated Hardware Bus Performance\u003c\/h3\u003e\n\u003cp\u003eThe module maintains low protocol conversion latencies by executing all Modbus TCP\/IP communication tasks directly on its local co-processor, fully isolating the 1769 backplane from network processing loads. DIN-rail mounting stability ensures physical alignment across the CompactLogix I\/O rack, protecting internal bus connections against continuous industrial vibration. The hardware supports up to 20 concurrent Client and 20 concurrent Server connections, converting Modbus Ethernet packets into backplane register transfers without impacting the main PLC sweep time.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the maximum current draw from the 1769 CompactLogix backplane?\u003c\/p\u003e\n\u003cp\u003eA: The module draws a maximum of 500 mA at 5 VDC directly from the 1769 backplane bus.\u003c\/p\u003e\n\u003cp\u003eQ: How does the power supply distance rating limit module placement?\u003c\/p\u003e\n\u003cp\u003eA: The module carries a power supply distance rating of 4 slots and must be installed within 4 slots of a 1769 system power supply.\u003c\/p\u003e\n\u003cp\u003eQ: Can this module be installed or removed while the 1769 rack is powered?\u003c\/p\u003e\n\u003cp\u003eA: No, the 1769 CompactLogix architecture does not support Removal and Insertion Under Power (RIUP). Power to the I\/O bank must be disconnected prior to installation or removal.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect all main system power sources from the 1769 CompactLogix rack before seating or unseating the module.\u003c\/li\u003e\n\u003cli\u003eEnsure the module is installed within a 4-slot radius of the system power supply to maintain adequate supply voltage across the backplane.\u003c\/li\u003e\n\u003cli\u003eSnap the module securely onto the 35 mm DIN rail and fully engage the upper and lower bus locking levers to couple with adjacent modules.\u003c\/li\u003e\n\u003cli\u003eRoute shielded Ethernet cables (Cat 5e or Cat 6) away from high-voltage wiring, AC power conductors, and motor drives to prevent noise coupling.\u003c\/li\u003e\n\u003cli\u003eGround the Ethernet cable shield at the switch end or patch panel to a designated single-point protective earth (PE) ground terminal.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":44006051217498,"sku":"MVI69E-MBTCP\/A","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/MVI69E-MBTCP1.jpg?v=1777456036"},{"product_id":"prosoft-mvi69-gsc-generic-serial-ascii-communication-module","title":"ProSoft MVI69-GSC Generic Serial ASCII Communication Module","description":"\u003cp\u003eConfigured for ASCII serial protocol conversion in CompactLogix 1769 systems, the \u003cstrong\u003eProSoft MVI69-GSC\u003c\/strong\u003e (\u003cstrong\u003eMVI69-GSC\u003c\/strong\u003e Generic Serial ASCII Network Interface Module) provides direct physical\/electrical execution. This single-slot module installs directly into the local backplane to route serial data streams up to 115.2k baud directly into process memory without processor overhead. The module features one dedicated configuration port alongside two fully isolated application ports supporting RS-232, RS-422, or RS-485 physical layer signal paths.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMVI69-GSC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eProSoft Technology \/ Allen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3.00 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C (32 to 140 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e800 mA max at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Controllers\u003c\/td\u003e\n\u003ctd\u003eCompactLogix, MicroLogix 1500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003e1 Configuration Port, 2 ASCII Application Ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Interfaces\u003c\/td\u003e\n\u003ctd\u003eRS-232, RS-422, RS-485 (Jumper Selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e500 V optical isolation from backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaud Rate\u003c\/td\u003e\n\u003ctd\u003e110 to 115.2k baud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Transfer\u003c\/td\u003e\n\u003ctd\u003eUp to 4000 registers to\/from control processor via Ladder Logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Distance Rating\u003c\/td\u003e\n\u003ctd\u003e2 slots\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProtocol Conversion Latencies \u0026amp; Isolation Properties\u003c\/h3\u003e\n\u003cp\u003eThe MVI69-GSC delivers low protocol conversion latencies when translating raw ASCII data streams into structured input\/output register tables for the 1769 processor. Designed with 500 V optical isolation between the serial channels and the 1769 backplane bus, the hardware prevents ground loops, common-mode noise corruption, and high-voltage field surges from propagating to the primary controller. Jumpers on the module allow precise selection of termination resistors and signal level configurations (RS-232 handshaking vs. RS-485 half-duplex \/ RS-422 full-duplex differential drives), ensuring signal integrity across long serial line runs.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the maximum distance the module can be placed from the 1769 system power supply?\u003c\/p\u003e\n\u003cp\u003eA: The MVI69-GSC has a Power Supply Distance Rating of 2. It must be installed within 2 slots of the system power supply on a 1769 bus or 1769-L43 \/ 1769-L45 CompactLogix controller system.\u003c\/p\u003e\n\u003cp\u003eQ: Can the application serial ports be hot-swapped while the CompactLogix rack is powered?\u003c\/p\u003e\n\u003cp\u003eA: No. The 1769 backplane architecture does not support RIUP (Removal and Insertion Under Power). Power to the 1769 bus must be disconnected before installing or removing the MVI69-GSC module to prevent hardware damage.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003ePower off the 1769 chassis before inserting or removing the module. Ensure the module locking lever is in the open position prior to seating.\u003c\/li\u003e\n\u003cli\u003eVerify that hardware jumpers for Port 1 and Port 2 are set correctly for the intended physical layer (RS-232, RS-422, or RS-485) before installing the module into the rack slot.\u003c\/li\u003e\n\u003cli\u003eAlign the module card guide with the adjacent module or power supply slots, slide the module firmly into place, and lock the upper and lower panel latches.\u003c\/li\u003e\n\u003cli\u003eRoute serial lines using shielded twisted-pair cabling. Connect cable shields to a single-point earth ground (PE) at the panel entry point to prevent signal noise and ground currents from entering the communication ports.\u003c\/li\u003e\n\u003cli\u003eDo not exceed the maximum baud rate limit of 115.2k baud, and maintain proper end-of-line termination (120 ohm) on all RS-485 network segments.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":44006068748378,"sku":"MVI69-GSC","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/MVI69E-MBS.jpg?v=1788148832"},{"product_id":"prosoft-mvi69l-mbtcp-modbus-tcp-ip-lite-communication-module","title":"ProSoft MVI69L-MBTCP Modbus TCP\/IP Lite Communication Module","description":"\u003cp\u003eConfigured for high-speed data transfer in Allen-Bradley CompactLogix systems, the \u003cstrong\u003eProSoft MVI69L-MBTCP\u003c\/strong\u003e (\u003cstrong\u003eMVI69L-MBTCP\u003c\/strong\u003e Modbus TCP\/IP Lite Communication Module) provides direct physical\/electrical execution. It functions as an in-chassis interface module that bridges 1769 backplane traffic to Ethernet-based Modbus TCP\/IP networks without introducing latency to the main controller logic execution cycle.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMVI69L-MBTCP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eProSoft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.32 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e450 mA max @ 5 VDC (Backplane Current Load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Platform\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley CompactLogix Processors (1769 Backplane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Port\u003c\/td\u003e\n\u003ctd\u003e1 x 10\/100 Mbps RJ45 Ethernet Port (Auto-Negotiating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Distance Rating\u003c\/td\u003e\n\u003ctd\u003e4 slots\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Data Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 240 Words Read \/ 240 Words Write\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModbus Client Connections\u003c\/td\u003e\n\u003ctd\u003eUp to 10 Client connections (16 commands per connection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModbus Server Connections\u003c\/td\u003e\n\u003ctd\u003eUp to 2 Server connections (1 MBAP \/ Port 502, 1 Encapsulated \/ Port 2000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFloating Point Data\u003c\/td\u003e\n\u003ctd\u003eSupported (IEEE 754, Enron, Daniel formats)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProtocol Conversion Latencies \u0026amp; Network Determinism\u003c\/h3\u003e\n\u003cp\u003eThe module executes protocol mapping asynchronously to the primary PAC scan cycle using internal memory allocation structures. Internal data buffer synchronization across the 1769 backplane limits protocol conversion latencies to under 20 ms for standard cyclic transfers. The single RJ45 port supports up to 10 concurrent active Client connections and 2 Server connections, allowing simultaneous query polling and incoming command processing while maintaining galvanic isolation between the field Ethernet infrastructure and the CompactLogix backplane system.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the maximum backplane distance rating for installation in a 1769 chassis?\u003c\/p\u003e\n\u003cp\u003eA: The MVI69L-MBTCP features a power supply distance rating of 4 slots. It must be installed within 4 slots of a 1769 power supply to ensure proper backplane power voltage integrity.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module handle non-standard 32-bit floating-point registers from third-party devices?\u003c\/p\u003e\n\u003cp\u003eA: The module configuration via ProSoft Configuration Builder (PCB) allows word-swapping and byte-swapping for IEEE 754 floating-point values, including Enron and Daniel style register mappings.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the module directly onto a standard 35 mm DIN rail or panel surface within a 1769 CompactLogix assembly, ensuring power is disconnected prior to insertion.\u003c\/li\u003e\n\u003cli\u003eObserve the 4-slot power supply distance rating limitation to prevent 5 VDC backplane voltage drop below operational thresholds.\u003c\/li\u003e\n\u003cli\u003eUtilize Category 5e or better shielded twisted-pair (STP) Ethernet cabling for field communication to prevent electromagnetic interference in industrial environments.\u003c\/li\u003e\n\u003cli\u003eConnect the RJ45 Ethernet shield to the system ground plane according to standard industrial grounding procedures to suppress common-mode noise.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":44006087786586,"sku":"MVI69L-MBTCP","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/MVI69L-MBTCP2.jpg?v=1788427404"},{"product_id":"prosoft-mvi69-pdpmv1-compactlogix-profibus-dp-master-module","title":"ProSoft MVI69-PDPMV1 CompactLogix PROFIBUS DP Master Module","description":"\u003cp\u003eThe \u003cstrong\u003eProSoft MVI69-PDPMV1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eMVI69-PDPMV1\u003c\/strong\u003e Master Communication Module, operates as a dedicated hardware component for PROFIBUS DP Master (V1) network interfacing within Allen-Bradley CompactLogix and MicroLogix 1500 architectures.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMVI69-PDPMV1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eProSoft Technology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.42 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e4.6 cm x 15.2 cm x 8.9 cm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C (32 deg F to 140 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e800 mA @ 5 VDC (Backplane current load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlatform Compatibility\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley CompactLogix (1769 backplane) and MicroLogix 1500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003e1 x DB9 Female (RS-485 optically isolated PROFIBUS DP), 1 x RJ45 (RS-232 serial config)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaud Rate\u003c\/td\u003e\n\u003ctd\u003e9.6 kbps to 12 Mbps (Auto-baud detection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlave Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 125 PROFIBUS DP Slave devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Data Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 1536 bytes Input \/ 1536 bytes Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProtocol Conversion Latencies \u0026amp; Bus Integration\u003c\/h3\u003e\n\u003cp\u003eThe MVI69-PDPMV1 interfaces directly over the local 1769 I\/O backplane bus, functioning as an in-rack input\/output module to achieve deterministic data transfer between the Rockwell Automation processor memory and connected field networks. Module communications process cyclic DP-V0 parameters alongside acyclic DP-V1 data messaging structures, minimizing internal protocol conversion latencies when polling variable frequency drives and process automation instrumentation. Dedicated optical isolation on the DB9 RS-485 transceiver stage suppresses common-mode voltage spikes and ground loops across network segments operating up to 12 Mbps.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the backplane power considerations when installing this module in a 1769 rack?\u003c\/p\u003e\n\u003cp\u003eA: The MVI69-PDPMV1 draws 800 mA at 5 VDC directly from the 1769 backplane bus. The power supply distance rating and total rack current budget must be verified to prevent logic bus voltage dips.\u003c\/p\u003e\n\u003cp\u003eQ: How is cyclic and acyclic data exchange managed between the module and controller?\u003c\/p\u003e\n\u003cp\u003eA: Cyclic I\/O and acyclic DP-V1 messaging are transferred across the backplane to the controller memory via standard ladder logic execution utilizing provided Add-On Instructions (AOI) and block transfer routines.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003ePower down the 1769 backplane expansion bank prior to inserting or removing the module. Hot-swapping on 1769 I\/O buses without removing system power is not supported and may result in hardware damage.\u003c\/li\u003e\n\u003cli\u003eSecure the module onto the standard DIN rail using the top and bottom latch mechanisms, ensuring full connection with the adjacent 1769 bus connector.\u003c\/li\u003e\n\u003cli\u003eTerminate the PROFIBUS DB9 connector using standard RS-485 shielded twisted-pair cabling. Ensure line termination resistors are switched to ON at the physical end nodes of the PROFIBUS segment.\u003c\/li\u003e\n\u003cli\u003eConnect the RS-485 shield braid to the local protective earth (PE) ground clamp to maintain EMC immunity and mitigate high-frequency field noise.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":44006122750042,"sku":"MVI69-PDPMV1","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/MVI69-PDPMV12.jpg?v=1788428649"},{"product_id":"prosoft-technology-mvi71-mcm-modbus-communication-module","title":"ProSoft Technology MVI71-MCM Modbus Communication Module","description":"\u003cp\u003eConfigured for bi-directional serial data transfer in Allen-Bradley PLC-5 systems, the \u003cstrong\u003eProSoft Technology MVI71-MCM\u003c\/strong\u003e (\u003cstrong\u003eMVI71-MCM\u003c\/strong\u003e Modbus Communication Module) provides direct physical\/electrical execution of Modbus RTU and ASCII protocol conversion across single-slot 1771 I\/O chassis platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMVI71-MCM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eProSoft Technology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.73 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C (32 to 140 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eBackplane Load: 800 mA @ 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley PLC-5 System (1771 I\/O Rack)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Ports\u003c\/td\u003e\n\u003ctd\u003e2 x RS-232 \/ RS-422 \/ RS-485 configurable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Protocols\u003c\/td\u003e\n\u003ctd\u003eModbus RTU \/ Modbus ASCII (Master or Slave per port)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaud Rates\u003c\/td\u003e\n\u003ctd\u003e110 bps to 115.2 kbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Transfer Method\u003c\/td\u003e\n\u003ctd\u003eBlock Transfer Read\/Write (BTR\/BTW) via Ladder Logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C (-40 to 185 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProtocol Conversion Latencies \u0026amp; Serial Bus Isolation\u003c\/h3\u003e\n\u003cp\u003eThe MVI71-MCM minimizes protocol conversion latencies through localized buffer management within the single-slot 1771 module footprint. Internal memory maps execute up to 100 Modbus command blocks per port directly to the PLC-5 processor registers via high-speed Block Transfer Read\/Write (BTR\/BTW) cycles. Physical communication interfaces utilize isolated line drivers for RS-232, RS-422, and RS-485 topology configurations, preventing ground loops and transient surge coupling across serial networks up to 115.2 kbps.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How is data synchronized between the MVI71-MCM and the PLC-5 processor backplane?\u003c\/p\u003e\n\u003cp\u003eA: Data transfer relies on standard Block Transfer Read (BTR) and Block Transfer Write (BTW) ladder logic instructions executed within the PLC-5 processor. Internal command blocks map Modbus register space directly into assigned backplane data files.\u003c\/p\u003e\n\u003cp\u003eQ: Can both serial ports on the MVI71-MCM operate under different Modbus configurations simultaneously?\u003c\/p\u003e\n\u003cp\u003eA: Yes, Port 1 and Port 2 are fully independent. Each port can be configured individually for Modbus Master or Slave functionality, running differing baud rates, parity settings, and physical layer standards (RS-232, RS-422, or RS-485).\u003c\/p\u003e\n\u003cp\u003eQ: What is the backplane current draw restriction for installing this module in a 1771 I\/O rack?\u003c\/p\u003e\n\u003cp\u003eA: The module draws up to 800 mA at 5 VDC from the 1771 chassis backplane. Ensure the rack power supply has adequate current margin before inserting the module into an active backplane power group.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003ePower off the target 1771 I\/O chassis before inserting or removing the MVI71-MCM module. Do not perform hot-swapping during active operation.\u003c\/li\u003e\n\u003cli\u003eVerify jumper block configurations on the module circuit board for RS-232, RS-422, or RS-485 operating modes prior to physical rack insertion.\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding of all shielded serial cable braids to a single-point protective earth (PE) ground to mitigate common-mode EMI noise.\u003c\/li\u003e\n\u003cli\u003eMaintain proper terminal connector torque and enforce standard NPT\/metric cable gland strain relief rules to avoid physical port stressing.\u003c\/li\u003e\n\u003cli\u003eAlign module circuit board edge connectors with the 1771 backplane slot guides and press firmly until locked in place.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":44006260834394,"sku":"MVI71-MCM","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/MVI71-MCM2.jpg?v=1788429051"},{"product_id":"prosoft-technology-mvi94-mcm-mhi-inrax-modbus-master-slave-communication-module","title":"ProSoft Technology MVI94-MCM-MHI inRAX Modbus Master\/Slave Communication Module","description":"\u003cp\u003eThe \u003cstrong\u003eProSoft Technology MVI94-MCM-MHI\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eMVI94-MCM-MHI\u003c\/strong\u003e Modbus Communication Interface Module, operates as a dedicated hardware component for serial protocol translation and data block transfers within Schneider Electric FLEX I\/O backplane architectures.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMVI94-MCM-MHI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eProSoft Technology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.44 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e800 mA @ 5 VDC (Backplane), 340 - 170 mA @ 12\/24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocol Support\u003c\/td\u003e\n\u003ctd\u003eModbus RTU \/ ASCII (Master or Slave)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Ports\u003c\/td\u003e\n\u003ctd\u003e2 ports (RS-232, RS-422, or RS-485 configurable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaud Rate\u003c\/td\u003e\n\u003ctd\u003e110 to 115,200 baud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Commands\u003c\/td\u003e\n\u003ctd\u003eUp to 100 user-configurable command blocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003eModule Status, Backplane Status, Port Activity (TX\/RX), Error Status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProtocol Conversion Latencies \u0026amp; Fieldbus Execution\u003c\/h3\u003e\n\u003cp\u003eThe MVI94-MCM-MHI module addresses protocol conversion latencies by executing cyclic input\/output data block transfers directly across the local backplane. Internal polling loops process up to 100 user-configurable command blocks, routing Modbus RTU or ASCII frame structures from field devices—such as variable frequency drives, power monitors, and flow meters—to designated host memory registers without introducing software-based handshake delays.\u003c\/p\u003e\n\u003cp\u003eDeterministic timing is maintained across both serial communication ports through dedicated buffer management. Each port operates independently in RS-232, RS-422, or RS-485 modes at baud rates up to 115,200 baud, maintaining low propagation delay during bidirectional Master\/Slave register updates.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the electrical constraints and backplane draw requirements for the MVI94-MCM-MHI module?\u003c\/p\u003e\n\u003cp\u003eA: The module draws up to 800 mA at 5 VDC from the backplane logic bus, alongside an external power loop requirement of 340 to 170 mA across a 12 to 24 VDC operating range.\u003c\/p\u003e\n\u003cp\u003eQ: How is serial line termination handled when operating RS-485 networks on Port 1 or Port 2?\u003c\/p\u003e\n\u003cp\u003eA: RS-485 differential signaling requires standard external 120 ohm terminating resistors across the physical lines at both extreme physical ends of the network trunk to prevent signal reflections and line degradation at higher baud rates.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the module onto the compatible FLEX I\/O terminal base unit, ensuring the locking mechanism engages firmly with the DIN-rail.\u003c\/li\u003e\n\u003cli\u003eVerify system power is off prior to inserting or removing the communication interface card to prevent transient voltage spikes on the backplane.\u003c\/li\u003e\n\u003cli\u003eRoute RS-232\/422\/485 communication cables separately from high-voltage AC power lines or VFD output wiring to avoid electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eConnect signal cable shielding to a clean single-point Earth ground (PE) at the panel entry point. Maintain shield continuity across all intermediate junction points without multipoint grounding loops.\u003c\/li\u003e\n\u003cli\u003eEnsure operating ambient temperatures around the base unit enclosure remain within the specified range of 0 to 60 deg C with passive air convection.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":44006337708122,"sku":"MVI94-MCM-MHI","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/MVI94-MCM1.jpg?v=1788155207"},{"product_id":"prosoft-plx31-eip-sie-industrial-ethernet-gateway","title":"ProSoft PLX31-EIP-SIE Industrial Ethernet Gateway","description":"\u003cp\u003eThe \u003cstrong\u003eProSoft PLX31-EIP-SIE\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003ePLX31-EIP-SIE\u003c\/strong\u003e Industrial Gateway, operates as a dedicated hardware component for protocol translation between EtherNet\/IP networks and Siemens S7 messaging environments within industrial control architectures.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePLX31-EIP-SIE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eProSoft Technology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.32 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e13.67 x 5.05 x 11.13 cm (5.38 x 1.99 x 4.38 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-25 to +70 deg C (-13 to +158 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal @ 300 mA (10 to 36 VDC @ 600 mA max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Ports\u003c\/td\u003e\n\u003ctd\u003e(2) 10\/100 Base-T RJ45 connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEtherNet\/IP Connections\u003c\/td\u003e\n\u003ctd\u003eUp to 16 Explicit Messaging Connections; Class 1 I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSiemens Protocol\u003c\/td\u003e\n\u003ctd\u003eS7 Messaging (Client\/Server)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTarget Siemens Controllers\u003c\/td\u003e\n\u003ctd\u003eS7-200, S7-300, S7-400, S7-1200, S7-1500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eStandard 35 mm DIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProtocol Conversion Latencies \u0026amp; Isolation\u003c\/h3\u003e\n\u003cp\u003eThe module provides full protocol conversion latencies optimization across isolated subnets via two discrete physical Ethernet interfaces. Deterministic data mapping minimizes memory block processing overhead between the EtherNet\/IP Class 1\/Class 3 driver buffers and the Siemens S7 client\/server driver stacks. Built-in port-to-port galvanic isolation prevents ground loop propagation across segmented plant networks while maintaining steady packet delivery without interconnecting IP subnets.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the gateway support seamless recovery if hardware replacement is required?\u003c\/p\u003e\n\u003cp\u003eA: Yes. Configuration state and data maps store directly on the local SD card slot, allowing zero-PC hardware restoration during module swapping.\u003c\/p\u003e\n\u003cp\u003eQ: Can both Ethernet ports operate on different IP subnet masks?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The two physical RJ45 Ethernet ports function independently, allowing routing-free data transfer between distinct subnets without bridging network traffic.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure standard 35 mm DIN rail grounding via low-impedance metallic connections. Maintain minimum 50 mm clearance above and below the module enclosure to allow adequate thermal convection inside high-density enclosures. Drain wire shielding from shielded Twisted Pair (STP) Cat 5e\/Cat 6 Ethernet cables must terminate directly to cabinet earth to prevent high-frequency noise from corrupting high-speed packet transfer.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":44006350684250,"sku":"PLX31-EIP-SIE","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/PLX31-EIP-PND1.jpg?v=1788157752"},{"product_id":"prosoft-plx31-mbtcp-mbs4-modbus-tcp-ip-to-modbus-serial-4-port-gateway","title":"ProSoft PLX31-MBTCP-MBS4 Modbus TCP\/IP to Modbus Serial 4 Port Gateway","description":"\u003cp\u003eThe \u003cstrong\u003eProSoft PLX31-MBTCP-MBS4\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003ePLX31-MBTCP-MBS4\u003c\/strong\u003e Modbus TCP\/IP to Modbus Serial 4 Port Gateway, operates as a dedicated hardware component for bidirectional protocol conversion and signal bridging within Modbus TCP\/IP networks and RS-232\/RS-422\/RS-485 serial field sub-networks.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel Code Segment\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eHardware\/Protocol Definition\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlatform Series\u003c\/td\u003e\n\u003ctd\u003ePLX31\u003c\/td\u003e\n\u003ctd\u003eCompact Standalone Industrial Standalone Gateway Platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Network\u003c\/td\u003e\n\u003ctd\u003eMBTCP\u003c\/td\u003e\n\u003ctd\u003eModbus TCP\/IP Client\/Server Ethernet Protocol Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecondary Network\u003c\/td\u003e\n\u003ctd\u003eMBS4\u003c\/td\u003e\n\u003ctd\u003eModbus Serial (RS-232\/422\/485) Master\/Slave Interface (4 Channels)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePLX31-MBTCP-MBS4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eProSoft Technology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.46 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e13.67 x 5.05 x 11.13 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-25 to 70 deg C (-13 to 158 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 80 deg C (-40 to 176 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal (10 to 36 VDC range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC @ 300 mA nominal, 10 to 36 VDC @ 610 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Port\u003c\/td\u003e\n\u003ctd\u003e10\/100 Mbit half-duplex, RJ45 connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Isolation\u003c\/td\u003e\n\u003ctd\u003e1500 Vrms at 50 to 60 Hz for 60 seconds (IEC 60950: 1991)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Ports\u003c\/td\u003e\n\u003ctd\u003e4 isolated serial channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Isolation\u003c\/td\u003e\n\u003ctd\u003e2500 Vrms signal isolation per UL 1577 (SiliconLabs Si844x RF technology)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock Ratings\u003c\/td\u003e\n\u003ctd\u003eIEC 60068-2-27; 15G @ 11ms (Operational), 30G @ 18ms (Non-Operational)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Ratings\u003c\/td\u003e\n\u003ctd\u003eIEC 60068-2-6; 5G @ 10 to 150 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLED Diagnostic Indicators\u003c\/td\u003e\n\u003ctd\u003eCFG, ERR, PWR, FLT, NS, MS, Link\/Act, Serial RX\/TX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Network Isolation \u0026amp; Protocol Conversion Latencies\u003c\/h3\u003e\n\u003cp\u003eThe PLX31-MBTCP-MBS4 incorporates high-speed RF-based digital galvantic isolation circuits across all four serial ports, utilizing SiliconLabs Si844x isolation components to achieve 2500 Vrms port-to-port and channel-to-ground dielectric protection. This isolation architecture prevents ground loop currents and transient voltage spikes from propagating between field-mounted Modbus serial devices and the upstream Modbus TCP\/IP Ethernet backbone. Protocol conversion latencies are minimized through an internal optimized memory map, enabling high-throughput data transfer between Ethernet buffers and serial UART transceivers without degrading deterministic poll cycles or causing packet collisions during multi-master polling operations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the gateway handle high-volume broadcast traffic on the Ethernet interface?\u003c\/p\u003e\n\u003cp\u003eA: The physical Ethernet controller implements hardware-level Broadcast Storm Resiliency. It restricts incoming Address Resolution Protocol (ARP) frame processing to a maximum rate of 5000 frames-per-second for durations up to 5 minutes, ensuring internal CPU resources remain dedicated to protocol execution during network flooding events.\u003c\/p\u003e\n\u003cp\u003eQ: What physical isolation mechanism is deployed on the serial communication channels?\u003c\/p\u003e\n\u003cp\u003eA: Each of the four serial ports utilizes SiliconLabs Si844x series digital isolators based on RF (Radio Frequency) modulation technology. This yields a 2500 Vrms signal isolation rating per UL 1577 between individual serial channels and internal logic circuits.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN-Rail Mounting \u0026amp; Enclosure Clearance:\u003c\/strong\u003e Secure the module on a standard 35 mm DIN rail in an vertical position inside an IP54 or higher industrial enclosure. Maintain a minimum top and bottom thermal clearance of 50 mm to facilitate natural convection cooling across the temperature operating range of -25 to 70 deg C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding \u0026amp; Shielding Execution:\u003c\/strong\u003e Connect the designated GND terminal on the power connector directly to the nearest low-impedance protective earth (PE) busbar using a short 14 AWG conductor. Connect serial communications cable shields strictly at one ground point to avoid circulating ground loop currents.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply \u0026amp; Wiring Limits:\u003c\/strong\u003e Wire the primary 24 VDC supply using copper conductors rated for at least 85 deg C. Ensure the power source output capacity accommodates the maximum inrush and steady-state current draw of 610 mA at the lower 10 VDC input threshold.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":44006362153050,"sku":"PLX31-MBTCP-MBS4","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/PLX31-MBTCP-MBS42.jpg?v=1788429761"},{"product_id":"prosoft-plx32-eip-sie-protocol-gateway","title":"ProSoft PLX32-EIP-SIE Protocol Gateway","description":"\u003cp\u003eThe \u003cstrong\u003eProSoft PLX32-EIP-SIE\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003ePLX32-EIP-SIE\u003c\/strong\u003e Standalone Gateway, operates as a dedicated hardware component for bi-directional protocol conversion between EtherNet\/IP and Siemens Industrial Ethernet networks within industrial automation platforms.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe base module identifier defines the physical enclosure and internal protocol driver matrix:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePLX32\u003c\/strong\u003e: ProSoft LineX express physical enclosure platform featuring dual isolated Ethernet interfaces, DIN-rail mount bracket, and SD card configuration slot.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEIP\u003c\/strong\u003e: Primary interface driver supporting EtherNet\/IP explicit\/implicit Class 1 messaging (Server\/Client).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSIE\u003c\/strong\u003e: Secondary interface driver executing Siemens Industrial Ethernet S7 messaging protocol over TCP\/IP (Server\/Client).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePLX32-EIP-SIE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eProSoft Technology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e118 x 45 x 107 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-25 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e240 mA @ 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e10 to 36 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Ports\u003c\/td\u003e\n\u003ctd\u003e2 x 10\/100 Mbps RJ45 ports (Isolated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Database Memory\u003c\/td\u003e\n\u003ctd\u003e10,000 words (16-bit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eIP20, Aluminum enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDynamic Protocol Conversion Latency \u0026amp; Subnet Isolation\u003c\/h3\u003e\n\u003cp\u003eThe dual RJ45 architecture provides galvanic and physical network separation between discrete Ethernet subnets. The module internal processing engine coordinates data transfer between the EtherNet\/IP driver and the Siemens Industrial Ethernet driver using an internal 10,000-word register database. Cross-subnet traffic isolation prevents broadcast storm propagation between ControlLogix and S7 networks while maintaining deterministic response latencies across both ports.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does replacing a PLX32-EIP-SIE module require a PC to restore configuration on-site?\u003c\/p\u003e\n\u003cp\u003eA: No. The unit features an integrated SD card slot. Moving the SD card from the existing gateway to a replacement unit restores all network configurations, mapping tables, and IP addresses automatically upon power-up.\u003c\/p\u003e\n\u003cp\u003eQ: Can both Ethernet ports be assigned to the same subnet for pass-through switching?\u003c\/p\u003e\n\u003cp\u003eA: No. The two Ethernet ports function as distinct, isolated network interfaces across separate subnets. They must be configured with independent IP addresses to facilitate cross-network mapping between EtherNet\/IP and Siemens subnets.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure the gateway is secured on a standard 35 mm DIN rail inside an IP54 or better enclosure to protect against environmental contaminants. Connect the protective earth (PE) ground wire directly to the ground screw terminal provided on the chassis using a minimum 14 AWG conductor. Maintain a minimum clearance of 50 mm above and below the device for convection airflow cooling. Ensure signal lines are routed away from high-voltage motor power cables to mitigate high-frequency EMI interference.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":44006373261402,"sku":"PLX32-EIP-SIE","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/PLX32-EIP-PND1.jpg?v=1764663834"},{"product_id":"prosoft-technology-plx32-mbtcp-pnd-protocol-gateway-module","title":"ProSoft Technology PLX32-MBTCP-PND Protocol Gateway Module","description":"\u003cp\u003eConfigured for bi-directional data conversion in PROFINET and Modbus TCP subnets, the \u003cstrong\u003eProSoft Technology PLX32-MBTCP-PND\u003c\/strong\u003e (\u003cstrong\u003ePLX32-MBTCP-PND\u003c\/strong\u003e Protocol Gateway) provides direct physical\/electrical execution. The hardware operates as a standalone PROFINET v2.2 Class A Device while concurrently supporting Modbus TCP Client and Server functionality over two physically isolated Ethernet channels. Internal memory buffers manage mapped I\/O data exchanges between separate network segments without requiring intermediate controller polling overhead.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePLX32-MBTCP-PND\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eProSoft Technology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.00 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e13.67 x 5.05 x 11.13 cm (5.38 x 1.99 x 4.38 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-25 to +70 deg C (-13 to +158 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC @ 100 mA (10 to 36 VDC @ 250 mA max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROFINET Role\u003c\/td\u003e\n\u003ctd\u003ePROFINET v2.2 Class A Device (Slave)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROFINET I\/O Capacity\u003c\/td\u003e\n\u003ctd\u003e1440 bytes Input \/ 1440 bytes Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModbus TCP Role\u003c\/td\u003e\n\u003ctd\u003eClient (Master) and Server (Slave) simultaneously\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Modbus Functions\u003c\/td\u003e\n\u003ctd\u003e1, 2, 3, 4, 5, 6, 15, 16, 22, 23\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Interface\u003c\/td\u003e\n\u003ctd\u003e2 x RJ45 (10\/100 Base-T, auto-crossover)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eStandard 35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Protocol Conversion Latencies \u0026amp; Bus Isolation\u003c\/h3\u003e\n\u003cp\u003eThe PLX32-MBTCP-PND utilizes dual independent 10\/100 Mbps Ethernet controllers to maintain deterministic protocol conversion latencies across separate subnets. Network traffic on the PROFINET interface does not leak into the Modbus TCP broadcast domain, eliminating network jitter caused by uncontrolled packet flooding.\u003c\/p\u003e\n\u003cp\u003eGalvanic isolation on the DC power terminal and Ethernet interfaces prevents ground loop currents from introducing data corruption or hardware failure in high-noise industrial environments. An integrated SD card interface facilitates direct flash memory cloning of gateway configuration profiles, minimizing hardware replacement downtime by allowing immediate parameter restoration without terminal software intervention.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How are isolated subnets maintained across the physical RJ45 interfaces?\u003c\/p\u003e\n\u003cp\u003eA: The gateway incorporates two distinct MAC addresses and network interface cards, preventing internal routing or bridged frame forwarding between the Modbus TCP and PROFINET physical ports.\u003c\/p\u003e\n\u003cp\u003eQ: What happens to the Modbus TCP network state if the PROFINET PLC enters a stop condition?\u003c\/p\u003e\n\u003cp\u003eA: The gateway maintains its internal database values or applies configured fail-safe options to the Modbus registers based on the command timeouts set in the ProSoft Configuration Builder utility.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the module vertically onto a standard 35 mm DIN rail, maintaining a minimum clearance of 50 mm above and below the enclosure for passive convection cooling.\u003c\/li\u003e\n\u003cli\u003eConnect the protective earth (PE) terminal directly to the central panel ground bus using a short, low-impedance copper conductor (minimum 14 AWG \/ 2.5 mm sq).\u003c\/li\u003e\n\u003cli\u003eRoute DC power wiring through a dedicated 10 to 36 VDC power supply, ensuring wire runs are physically separated from high-voltage motor lead conduits.\u003c\/li\u003e\n\u003cli\u003eInsert Cat5e or Cat6 shielded twisted-pair (STP) cables into the RJ45 Ethernet ports, verifying that cable shield drains ground through the RJ45 connector housing.\u003c\/li\u003e\n\u003cli\u003eFormat the configuration backup SD card using FAT32 before inserting it into the designated module slot prior to initial commissioning.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":44006381420634,"sku":"PLX32-MBTCP-PND","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/PLX32-EIP-MBTCP1.jpg?v=1788158940"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/collections\/ProSoft.png?v=1725519747","url":"https:\/\/www.plcmasters.com\/collections\/prosoft.oembed?page=4","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}