{"product_id":"bently-nevada-80917-01-keyphasor-conditioner-power-supply","title":"Bently Nevada 80917-01 Keyphasor Conditioner \u0026 Power Supply","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e80917-01 (TK15)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a compact, field-deployable Keyphasor® conditioning instrument designed to supply power to Keyphasor® transducers while converting raw pickup signals into stable, analysis-ready phase reference outputs. It supports simultaneous processing of two independent Keyphasor channels, making it suitable for both on-site troubleshooting and controlled bench diagnostics.\u003c\/p\u003e\n\u003cp\u003eThis instrument is commonly used alongside Bently Nevada portable diagnostic platforms and monitoring systems to establish accurate shaft phase, speed reference, and once-per-revolution signals for rotating machinery analysis.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFunctional Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e80917-01 (TK15)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eintegrates regulated transducer excitation and signal conditioning within a single portable enclosure. It accepts inputs from optical Keyphasor pickups as well as proximity probe-based Keyphasor configurations, filtering and shaping these inputs into consistent logic-level or analog outputs suitable for advanced vibration and rotor dynamics analysis.\u003c\/p\u003e\n\u003cp\u003eIts portable form factor allows engineers to deploy it directly in the field without relying on permanent rack-mounted infrastructure.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e2 fully independent Keyphasor® input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Transducers\u003c\/td\u003e\n\u003ctd\u003eOptical Keyphasor® pickups, Proximitor®-based Keyphasor probes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Processing\u003c\/td\u003e\n\u003ctd\u003eConditioning, shaping, and stabilization of phase reference signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eConditioned logic-level and\/or analog phase reference outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransducer Power\u003c\/td\u003e\n\u003ctd\u003eInternal regulated excitation supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Capability\u003c\/td\u003e\n\u003ctd\u003eDesigned for low- to high-speed rotating machinery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003eApproximately -20 °C to +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003ePortable, bench-top or field instrument\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e229 × 102 × 51 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e80917-01 (TK15)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis typically used with:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eBently Nevada ADRE® diagnostic systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePortable vibration analyzers requiring external Keyphasor conditioning\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOffline rotor dynamics and balancing setups\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMachinery monitoring environments where a temporary phase reference is required\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIt complements permanently installed monitoring systems such as the 3500 Series by providing a flexible diagnostic alternative.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTypical Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eEstablishing phase reference for turbine vibration and orbit analysis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRotor dynamic testing during commissioning or maintenance outages\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShaft speed and phase verification on compressors and pumps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eField diagnostics for motors and generators\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTemporary Keyphasor signal conditioning during troubleshooting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the TK15 be used with proximity probes instead of optical sensors?\u003c\/strong\u003e\u003cbr\u003eYes. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e80917-01 (TK15)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports both optical Keyphasor pickups and Proximitor®-based Keyphasor probe configurations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this unit intended for permanent installation?\u003c\/strong\u003e\u003cbr\u003eNo. It is designed as a portable instrument for temporary field use or bench-top diagnostics rather than continuous rack-mounted operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many phase reference signals can be processed at the same time?\u003c\/strong\u003e\u003cbr\u003eThe unit provides two fully independent channels, allowing simultaneous conditioning of two Keyphasor signals.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":42734246428762,"sku":"80917-01","price":226.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/80917-012.jpg?v=1767857116","url":"https:\/\/www.plcmasters.com\/de\/products\/bently-nevada-80917-01-keyphasor-conditioner-power-supply","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}