Descripción
Product Description
The KC4011X1-BQ1 from Emerson is a 40-pin simplex discrete output (DO) mass terminal block designed for DeltaV systems. It provides a secure and organized interface for connecting multiple DO cards to field devices, ensuring reliable signal distribution in hazardous areas.
Engineered for Zone 2 / Class I Division 2 installations, this terminal block features LS1 keyed connections to prevent wiring errors. Its robust construction ensures operation under extreme temperatures, humidity, vibration, and shock conditions. The compact form factor simplifies installation while maintaining high reliability for process automation applications.
Technical Specifications
-
Model: KC4011X1-BQ1
-
Module Type: Simplex Discrete Output Mass Terminal Block
-
Channels: 40-pin connections for discrete outputs
-
Compatibility: Designed for Emerson DeltaV DO cards (S-series and SIS systems)
-
Nominal Voltage: 24 VDC
-
Field Circuit Power: 24 VDC at 100 mA per channel
-
Dimensions: 110 × 45 × 120 mm
-
Weight: 0.4 kg
-
Operating Temperature: –40 °C to +70 °C
-
Humidity: 5–95% RH, non-condensing
-
Shock Resistance: 10 g, half-sine wave, 11 ms
-
Vibration: 2–13.2 Hz: 1 mm peak-to-peak; 13.2–150 Hz: 0.7 g
-
Airborne Contaminants: ISA-S71.04-1985 Class G3
-
Terminal Block Key Position: B4
Safety & Compliance
-
Hazardous Atmosphere Ratings:
-
II 3G Ex ec IIC Gc
-
Class I, Division 2, Groups A–D
-
Zone 2 AEx/Ex ec IIC Gc
-
Certifications: ATEX, IECEx, FM, UKEX approvals for hazardous locations
-
Installation Note: Follow proper procedures for installation, removal, and operation in hazardous areas
Key Highlights
-
Provides mass termination for up to 40 discrete outputs, reducing wiring complexity
-
Certified for hazardous environments (Zone 2 / Class I Div. 2)
-
Rugged design withstands temperature extremes, vibration, and shock
-
Compact and lightweight for easy integration into DeltaV racks
-
Ensures consistent and reliable signal distribution for control and automation
Applications
-
Termination of multiple discrete output signals in DeltaV systems
-
Hazardous area installations for process control in oil, gas, and chemical plants
-
Field wiring organization and protection for DO cards
FAQ
Q: Can KC4011X1-BQ1 be used with SIS DeltaV cards?
A: Yes, it is compatible with both standard S-series and SIS DO cards.
Q: What is the maximum current per channel?
A: Each channel supports up to 100 mA at 24 VDC.
Q: Is this terminal block suitable for Zone 2 hazardous areas?
A: Yes, it meets ATEX, IECEx, FM, and UKEX standards for Zone 2 / Class I Div. 2 environments.
Características
Damos la bienvenida a pedidos al por mayor y tenemos una cantidad mínima de pedido de solo una unidad.
Si lo solicita, podemos proporcionar toda la documentación necesaria, incluidos los Certificados de Origen/Conformidad y otros documentos de exportación requeridos.
Para los artículos en stock, nuestro objetivo es entregar dentro de 1-3 días después de la confirmación del pago. Los artículos con plazos especificados se entregarán según el calendario indicado.
Aceptamos pago 100% T/T (Transferencia telegráfica) antes del envío. Para artículos con tiempos de entrega, se requiere un depósito del 30% por adelantado, con el 70% restante debido antes del envío. Para transferencias en RMB, por favor contáctenos si tiene un agente en China.
Ofrecemos una garantía estándar de un año en todos los artículos nuevos y originales. Si necesita una garantía extendida, por favor contáctenos para obtener detalles sobre costos adicionales.
Su satisfacción es importante para nosotros. Si necesita devolver un artículo, debe hacerlo dentro de los 30 días posteriores a la fecha del pedido. El producto debe estar sin usar, sin abrir y en su embalaje original con todos los accesorios incluidos. Los reembolsos se procesan dentro de 5-7 días hábiles después de que recibamos el artículo devuelto. Tenga en cuenta que los gastos de envío y cargos relacionados no son reembolsables.