The KL3104X1-BA1 is an intrinsically safe (I.S.) discrete output CHARM module from Emerson, designed for DeltaV systems. It provides up to 45 mA digital output signals, enabling safe control of actuators, solenoids, and other low-power field devices in hazardous areas.
Engineered for Zone 2 / Class I Division 2 environments, this module offers compact CHARM integration, robust environmental resistance, and reliable operation under vibration, shock, and airborne contaminant exposure. The keyed 3E terminal block ensures proper installation and wiring security. With no user-serviceable parts and no calibration required, KL3104X1-BA1 delivers maintenance-free, dependable performance.
Technical Specifications
-
Model: KL3104X1-BA1
-
Module Type: Intrinsically Safe Discrete Output (DO) CHARM
-
Output Signal: Digital, up to 45 mA
-
Safety Type: Intrinsically Safe (I.S.)
-
CHARM Bus Power: +6.3 VDC, 0 mA
-
Field Circuit Power: +24 VDC, 78 mA
-
Channels: Single-channel output
-
Terminal Block Key Position: 3E
-
Operating Temperature: –40 °C to +70 °C
-
Humidity: 5–95% RH, non-condensing
-
Shock Resistance: 10 g, half-sine wave, 11 ms
-
Vibration: 2–13.2 Hz: 1 mm peak-to-peak; 13.2–150 Hz: 0.7 g
-
Airborne Contaminants: ISA-S71.04-1985 Class G3
-
Weight: 0.51 lbs
Safety & Compliance
-
Hazardous Atmosphere Ratings:
-
II 3(1) G Ex ec [ia Ga] IIC Gc
-
II 3G (1D) Ex ec [ia IIIC Da] IIC Gc
-
Class I, Division 2, Groups A–D
-
Zone 2 AEx ec [ia Ga/IIIC Da] IIC Gc
-
Certifications: ATEX, IECEx, FM, UKEX
-
Installation Note: Must not be inserted or removed while energized unless the area is confirmed non-hazardous
Key Highlights
-
Provides intrinsically safe discrete output for hazardous areas
-
Supports low-power devices with up to 45 mA drive capability
-
Compact CHARM form factor allows seamless DeltaV system integration
-
Wide environmental tolerance: –40 °C to +70 °C, Class G3 airborne contaminants
-
Keyed terminal block ensures correct installation and wiring
Applications
-
Driving actuators, solenoids, and field indicators in hazardous environments
-
DeltaV systems requiring single-channel intrinsically safe outputs
-
Oil, gas, and chemical plants with Zone 2 / Class I Div. 2 installations
FAQ
Q: Can this module be used in Zone 2 hazardous areas?
A: Yes, the KL3104X1-BA1 is intrinsically safe and certified for Zone 2 / Class I Division 2.
Q: What is the maximum output current?
A: The module supports discrete output signals up to 45 mA per channel.
Q: Is calibration required?
A: No, the module requires no calibration and has no user-serviceable parts.
Características
Damos la bienvenida a pedidos al por mayor y tenemos una cantidad mínima de pedido de solo una unidad.
Si lo solicita, podemos proporcionar toda la documentación necesaria, incluidos los Certificados de Origen/Conformidad y otros documentos de exportación requeridos.
Para los artículos en stock, nuestro objetivo es entregar dentro de 1-3 días después de la confirmación del pago. Los artículos con plazos especificados se entregarán según el calendario indicado.
Aceptamos pago 100% T/T (Transferencia telegráfica) antes del envío. Para artículos con tiempos de entrega, se requiere un depósito del 30% por adelantado, con el 70% restante debido antes del envío. Para transferencias en RMB, por favor contáctenos si tiene un agente en China.
Ofrecemos una garantía estándar de un año en todos los artículos nuevos y originales. Si necesita una garantía extendida, por favor contáctenos para obtener detalles sobre costos adicionales.
Su satisfacción es importante para nosotros. Si necesita devolver un artículo, debe hacerlo dentro de los 30 días posteriores a la fecha del pedido. El producto debe estar sin usar, sin abrir y en su embalaje original con todos los accesorios incluidos. Los reembolsos se procesan dentro de 5-7 días hábiles después de que recibamos el artículo devuelto. Tenga en cuenta que los gastos de envío y cargos relacionados no son reembolsables.