Descripción
Product Description
The KL3106X1-BA1 is an intrinsically safe (I.S.) analog input CHARM module from Emerson, specifically designed for thermocouple signal acquisition in DeltaV systems. It allows precise and reliable temperature measurement in hazardous areas while maintaining compliance with global safety standards.
This compact CHARM module integrates directly into DeltaV racks, providing single-channel thermocouple input with low CHARM bus power consumption. The terminal block key position BA1 ensures correct wiring and installation, while the rugged design withstands vibration, shock, and airborne contaminants. No calibration is required, and the module has no user-serviceable parts, making it maintenance-free.
Technical Specifications
-
Model: KL3106X1-BA1
-
Module Type: Intrinsically Safe Analog Input (AI) CHARM
-
Signal Type: Thermocouple input (supports multiple types)
-
Safety Type: Intrinsically Safe (I.S.)
-
CHARM Bus Power: +6.3 VDC at minimal current
-
Field Circuit Power: +24 VDC, ~23 mA
-
Channels: Single-channel
-
Terminal Block Key Position: BA1
-
Operating Temperature: –40 °C to +70 °C
-
Humidity: 5–95% RH, non-condensing
-
Shock Resistance: 10 g, half-sine wave, 11 ms
-
Vibration: 2–13.2 Hz: 1 mm peak-to-peak; 13.2–150 Hz: 0.7 g
-
Airborne Contaminants: ISA-S71.04-1985 Class G3
Safety & Compliance
-
Hazardous Atmosphere Ratings:
-
II 3(1) G Ex ec [ia Ga] IIC Gc
-
II 3G (1D) Ex ec [ia IIIC Da] IIC Gc
-
Class I, Division 2, Groups A–D
-
Zone 2 AEx ec [ia Ga/IIIC Da] IIC Gc
-
Certifications: ATEX, IECEx, FM, UKEX
-
Installation Note: Do not insert or remove while energized unless area is confirmed non-hazardous
Key Highlights
-
Single-channel thermocouple input for accurate temperature measurement
-
Intrinsically safe design suitable for hazardous environments
-
Compact CHARM form factor for seamless DeltaV system integration
-
Wide environmental tolerance: –40 °C to +70 °C, Class G3 airborne contaminants
-
Keyed terminal block BA1 ensures proper connection and installation
Applications
-
Hazardous area temperature monitoring using thermocouples
-
DeltaV systems requiring single-channel intrinsically safe analog input
-
Process plants in oil, gas, chemical, or other Zone 2 / Class I Div. 2 environments
FAQ
Q: Which thermocouple types are supported by KL3106X1-BA1?
A: The module supports standard thermocouple types (J, K, T, E, R, S, B, N) depending on configuration.
Q: Can it be used in Class I Division 2 areas?
A: Yes, it is certified for Zone 2 / Class I Div. 2 hazardous areas.
Q: Is calibration required for operation?
A: No, the module is factory-calibrated and requires no user maintenance.
Características
Damos la bienvenida a pedidos al por mayor y tenemos una cantidad mínima de pedido de solo una unidad.
Si lo solicita, podemos proporcionar toda la documentación necesaria, incluidos los Certificados de Origen/Conformidad y otros documentos de exportación requeridos.
Para los artículos en stock, nuestro objetivo es entregar dentro de 1-3 días después de la confirmación del pago. Los artículos con plazos especificados se entregarán según el calendario indicado.
Aceptamos pago 100% T/T (Transferencia telegráfica) antes del envío. Para artículos con tiempos de entrega, se requiere un depósito del 30% por adelantado, con el 70% restante debido antes del envío. Para transferencias en RMB, por favor contáctenos si tiene un agente en China.
Ofrecemos una garantía estándar de un año en todos los artículos nuevos y originales. Si necesita una garantía extendida, por favor contáctenos para obtener detalles sobre costos adicionales.
Su satisfacción es importante para nosotros. Si necesita devolver un artículo, debe hacerlo dentro de los 30 días posteriores a la fecha del pedido. El producto debe estar sin usar, sin abrir y en su embalaje original con todos los accesorios incluidos. Los reembolsos se procesan dentro de 5-7 días hábiles después de que recibamos el artículo devuelto. Tenga en cuenta que los gastos de envío y cargos relacionados no son reembolsables.