Descripción
Product Description
The KL3106X1-LS1 from Emerson is a single-channel analog input CHARM module engineered for thermocouple signals in DeltaV systems. Its intrinsically safe (I.S.) design ensures secure operation in hazardous environments, including Zone 2 and Class I Division 2 locations.
Featuring LS1 keyed terminals, this module prevents miswiring and simplifies installation. The compact CHARM format allows seamless integration into DeltaV racks while maintaining a minimal CHARM bus power draw. With broad environmental tolerance and robust resistance to shock, vibration, and airborne contaminants, it provides reliable temperature measurement in industrial conditions.
Technical Specifications
-
Model: KL3106X1-LS1
-
Module Type: Intrinsically Safe (I.S.) Analog Input CHARM
-
Signal Type: Thermocouple input (supports multiple types)
-
Safety Type: Intrinsically Safe (I.S.)
-
CHARM Bus Power: +6.3 VDC at minimal consumption
-
Field Circuit Power: +24 VDC, ~60 mA
-
Channels: Single-channel CHARM
-
Terminal Block Key Position: LS1
-
Operating Temperature: –40 °C to +70 °C
-
Humidity: 5–95% RH, non-condensing
-
Shock Resistance: 10 g, half-sine wave, 11 ms
-
Vibration: 2–13.2 Hz: 1 mm peak-to-peak; 13.2–150 Hz: 0.7 g
-
Airborne Contaminants: ISA-S71.04-1985 Class G3
-
Maintenance: No calibration required; no user-serviceable parts
Safety & Compliance
-
Hazardous Atmosphere Ratings:
-
II 3(1) G Ex ec [ia Ga] IIC Gc
-
II 3G (1D) Ex ec [ia IIIC Da] IIC Gc
-
Class I, Division 2, Groups A–D
-
Zone 2 AEx ec [ia Ga] IIC Gc
-
Certifications: ATEX, IECEx, FM, UKEX
-
Installation Note: Do not insert or remove while energized unless area is verified non-hazardous
Key Highlights
-
Single-channel thermocouple input for accurate temperature monitoring
-
Intrinsically safe design for hazardous area applications
-
LS1 keyed terminal block ensures proper wiring and safe installation
-
Broad environmental tolerance: –40 °C to +70 °C; resistant to shock, vibration, and Class G3 airborne contaminants
-
Compact CHARM module for seamless DeltaV system integration
Applications
-
Temperature measurement in hazardous areas using thermocouples
-
Integration into DeltaV I/O systems for process control
-
Suitable for oil, gas, chemical, and other Zone 2 / Class I Div. 2 industrial environments
FAQ
Q: Which thermocouple types are compatible with KL3106X1-LS1?
A: Supports standard thermocouples including types J, K, T, E, R, S, B, and N depending on configuration.
Q: Can this module be installed in Zone 2 locations?
A: Yes, it is certified for Zone 2 and Class I Division 2 hazardous areas.
Q: Is calibration required before operation?
A: No, the module is factory-calibrated and maintenance-free.
Características
Damos la bienvenida a pedidos al por mayor y tenemos una cantidad mínima de pedido de solo una unidad.
Si lo solicita, podemos proporcionar toda la documentación necesaria, incluidos los Certificados de Origen/Conformidad y otros documentos de exportación requeridos.
Para los artículos en stock, nuestro objetivo es entregar dentro de 1-3 días después de la confirmación del pago. Los artículos con plazos especificados se entregarán según el calendario indicado.
Aceptamos pago 100% T/T (Transferencia telegráfica) antes del envío. Para artículos con tiempos de entrega, se requiere un depósito del 30% por adelantado, con el 70% restante debido antes del envío. Para transferencias en RMB, por favor contáctenos si tiene un agente en China.
Ofrecemos una garantía estándar de un año en todos los artículos nuevos y originales. Si necesita una garantía extendida, por favor contáctenos para obtener detalles sobre costos adicionales.
Su satisfacción es importante para nosotros. Si necesita devolver un artículo, debe hacerlo dentro de los 30 días posteriores a la fecha del pedido. El producto debe estar sin usar, sin abrir y en su embalaje original con todos los accesorios incluidos. Los reembolsos se procesan dentro de 5-7 días hábiles después de que recibamos el artículo devuelto. Tenga en cuenta que los gastos de envío y cargos relacionados no son reembolsables.