{"product_id":"epro-con021-pr6423-010-130-eddy-current-monitoring-system","title":"EPRO CON021+PR6423\/010-130 Eddy Current Monitoring System","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEPRO CON021\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esignal converter paired with the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePR6423\/010-130\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eeddy current probe delivers a comprehensive solution for high-precision monitoring of turbomachinery. This combination enables non-contact measurement of shaft displacement, position, eccentricity, and vibration in steam, gas, and hydro turbines, as well as pumps, compressors, and fans. Engineered for reliability in harsh industrial environments, the system ensures accurate dynamic monitoring and seamless integration with Emerson MMS 6000 and IMR 6000 monitoring racks.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSystem Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe monitoring chain comprises:\u003cbr\u003eProbe → Signal Converter → Rack\/Monitoring System\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePR6423\/010-130\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprobe features a 25 mm sensor head and a 13 m cable, providing flexibility for installation in large machinery. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCON021\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econverter processes signals with high accuracy and outputs standardized analog signals compatible with existing monitoring infrastructure.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ch3\u003e\u003cstrong\u003eCON021 Signal Converter\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eEddy current signal conversion for displacement, position, eccentricity, and speed\/key monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003e0 – 20 kHz (-3 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Sensors\u003c\/td\u003e\n\u003ctd\u003ePR6422, PR6423, PR6424, PR6425, PR6426, PR6453\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e-23V to -32V (Output -4V to -20V) \/ -21V to -32V (Output -2V to -18V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003eStandardized analog voltage output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-30°C to +100°C (-22°F to +212°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock \u0026amp; Vibration\u003c\/td\u003e\n\u003ctd\u003e5g @ 60 Hz, 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eRack-based (MMS 6000 \/ IMR 6000 compatible)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegration\u003c\/td\u003e\n\u003ctd\u003eHot-swappable installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003ePR6423\/010-130 Eddy Current Probe\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Type\u003c\/td\u003e\n\u003ctd\u003eEddy current displacement and vibration probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Head Diameter\u003c\/td\u003e\n\u003ctd\u003e25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e2 V\/mm (~50.8 mV\/mil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Measuring Range\u003c\/td\u003e\n\u003ctd\u003e±2.0 mm (0.079”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Air Gap\u003c\/td\u003e\n\u003ctd\u003e~2.5 mm (0.10”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e≤ ±1.5% long-term drift\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-35°C to +180°C (short excursions up to +200°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Temperature\u003c\/td\u003e\n\u003ctd\u003eUp to +200°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e13.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eLEMO connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eComplete eddy current monitoring chain: probe + converter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNon-contact measurement avoids mechanical wear\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-speed response with rise time under 15 μs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial-grade durability in high-temperature, pressure, and vibration environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFlexible installation with 13 m cable length\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHot-swappable rack integration with MMS 6000 \/ IMR 6000\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSteam, gas, and hydro turbines\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePumps, compressors, and fans\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRotating machinery condition monitoring and protection systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the PR6423\/010-130 probe be used with other converters?\u003c\/strong\u003e\u003cbr\u003eA: It is optimized for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCON021\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econverters, but may be compatible with other models in the Emerson PR642x series with proper configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum operating temperature for the probe cable?\u003c\/strong\u003e\u003cbr\u003eA: The cable can handle temperatures up to +200°C.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Are there shorter or longer cable variants?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the PR6423 series offers multiple cable lengths; the 010-130 variant provides 13 m.\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":42828414287962,"sku":"CON021+PR6423\/010-130","price":178.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/CON021_PR6423010-1302.jpg?v=1769502320","url":"https:\/\/www.plcmasters.com\/es\/products\/epro-con021-pr6423-010-130-eddy-current-monitoring-system","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}