توضیحات
Overview
The EPRO CON021/915-080 is a high-precision eddy current signal converter designed for rotating machinery monitoring. It accurately measures shaft displacement, position, eccentricity, and speed/key signals. It is widely used in steam, gas, and hydro turbines, as well as compressors, pumps, and fans.
This model works with multiple eddy current probes, including PR6422, PR6423, PR6424, PR6425 (requires extended range converter), PR6426, and PR6453. It converts sensor signals into standardized analog outputs for integration with monitoring and protection systems. The CON021/915-080 is optimized for MMS 6000 and IMR 6000 rack systems and supports hot-swappable installation, ensuring continuous operation of critical rotating equipment.
Technical Specifications
| Parameter | Specification |
|---|---|
| Function | Eddy current signal converter for shaft displacement, position, eccentricity, and speed/key monitoring |
| Frequency Range | 0–20 kHz (-3 dB) |
| Rise Time | <15 μs for accurate dynamic measurement |
| Compatible Sensors | PR6422, PR6423, PR6424, PR6425 (extended range), PR6426, PR6453 |
| Supply Voltage | -23V to -32V (Output -4V to -20V) -21V to -32V (Output -2V to -18V) |
| Output Signal | Standardized analog output (depending on configuration) |
| Operating Temperature | -30°C to +100°C (-22°F to +212°F) |
| Shock & Vibration | 5g @ 60 Hz @ 25°C |
| Protection Class | IP20 |
| Housing Material | LMgSi 0.5 F22 Aluminum Alloy |
| Weight | 120 g |
| Mounting | Rack-based installation (MMS 6000 / IMR 6000 compatible) |
| Connections | Self-locking LEMO plug or screw terminal options |
| Integration | Hot-swappable for rack systems |
Applications
-
Steam, gas, and hydro turbine monitoring
-
Rotating machinery: compressors, pumps, and fans
-
Process control and protection systems
FAQ
Q1: Which sensors are compatible with CON021/915-080?
A1: Compatible with PR6422, PR6423, PR6424, PR6425 (extended range), PR6426, and PR6453.
Q2: Can this module be replaced while running?
A2: Yes, it supports hot-swappable installation in MMS 6000 and IMR 6000 racks.
Q3: What is the typical measurement range?
A3: Using PR6425 extended range, ±8.0 mm with ≤3% linearity error.
Q4: What is the operating temperature range?
A4: -30°C to +100°C, suitable for most industrial rotating machinery environments.
ویژگیها
ما سفارشهای عمده را میپذیریم و حداقل تعداد سفارش فقط یک واحد است.
به درخواست، ما میتوانیم تمام مدارک لازم، از جمله گواهیهای مبدا/انطباق و سایر مدارک صادراتی مورد نیاز را ارائه دهیم.
برای کالاهای موجود در انبار، هدف ما تحویل در عرض ۱ تا ۳ روز پس از تأیید پرداخت است. کالاهایی که زمان تحویل مشخصی دارند، طبق برنامه اعلام شده تحویل داده خواهند شد.
ما پرداخت 100% T/T (انتقال تلگرافی) را قبل از ارسال قبول میکنیم. برای کالاهایی با زمان تحویل، 30% پیشپرداخت لازم است و 70% باقیمانده قبل از ارسال پرداخت میشود. برای انتقالات RMB، لطفاً اگر نمایندهای در چین دارید با ما تماس بگیرید.
ما یک سال گارانتی استاندارد برای تمام کالاهای جدید و اصلی ارائه میدهیم. اگر به گارانتی تمدید شده نیاز دارید، لطفاً برای جزئیات هزینه اضافی با ما تماس بگیرید.
رضایت شما برای ما مهم است. اگر نیاز به بازگرداندن کالا دارید، باید این کار ظرف ۳۰ روز از تاریخ سفارش انجام شود. محصول باید استفاده نشده، باز نشده و در بستهبندی اصلی خود با تمام لوازم جانبی همراه باشد. بازپرداختها ظرف ۵-۷ روز کاری پس از دریافت کالای بازگردانده شده پردازش میشوند. لطفاً توجه داشته باشید که هزینههای حمل و نقل و هزینههای مرتبط قابل بازپرداخت نیستند.