The KL3101X1-BA1 is an intrinsically safe (I.S.) analog input CHARM module from Emerson, engineered for DeltaV systems. It allows safe acquisition of 4–20 mA signals from HART-enabled field devices in hazardous environments, providing both measurement and diagnostic capabilities in a compact CHARM form factor.
This module is designed for installations in Zone 2 / Class I Division 2 areas, combining intrinsic safety, robust environmental tolerance, and compliance with ATEX, IECEx, FM, and UKEX standards. Its low-power CHARM bus interface and reliable 24 VDC field circuit support stable operation under demanding conditions.
Core Technical Specifications
-
Model: KL3101X1-BA1
-
Module Type: Intrinsically Safe Analog Input (I.S.) CHARM
-
Signal Type: 4–20 mA analog input with HART communication
-
Safety Classification: Intrinsically Safe (I.S.)
-
CHARM Bus Power: +6.3 VDC, 0 A nominal
-
Field Circuit Power: +24 VDC at 60 mA
-
Terminal Block Key: A1
-
Operating Temperature: –40 °C to +70 °C
-
Relative Humidity: 5–95%, non-condensing
-
Shock Resistance: 10 g, half-sine, 11 ms
-
Vibration: 2–13.2 Hz: 1 mm peak-to-peak; 13.2–150 Hz: 0.7 g
-
Airborne Contaminants Rating: ISA-S71.04 Class G3
-
Weight: 0.14 lbs
Safety & Compliance
-
Hazardous Atmosphere Ratings:
-
II 3(1) G Ex ec [ia Ga] IIC Gc
-
II 3G (1D) Ex ec [ia IIIC Da] IIC Gc
-
Class I, Division 2, Groups A–D
-
Zone 2 AEx ec [ia Ga / IIIC Da]
-
Certifications: ATEX, IECEx, FM, UKEX
-
Installation Note: Must not be inserted or removed while energized unless the area is confirmed non-hazardous
Functional Advantages
-
Intrinsically safe design suitable for hazardous locations
-
HART support enables device diagnostics and configuration without extra wiring
-
Wide environmental tolerance for extreme temperatures and airborne contaminants
-
Compact CHARM format integrates seamlessly into DeltaV I/O systems
-
Maintenance-free operation; no calibration required
Applications
-
Oil and gas process control panels
-
Chemical and petrochemical plant field monitoring
-
Remote hazardous area I/O installations
-
Integration with DeltaV distributed control systems
FAQ
Q: Can this module operate in Zone 2 / Class I Div. 2 hazardous areas?
A: Yes, the KL3101X1-BA1 is certified intrinsically safe for Zone 2 / Class I Division 2 locations.
Q: Does it require periodic calibration?
A: No, the module is maintenance-free and factory-calibrated.
Q: What HART capabilities does it support?
A: Full pass-through communication for diagnostics and configuration of HART-enabled transmitters.
ویژگیها
ما سفارشهای عمده را میپذیریم و حداقل تعداد سفارش فقط یک واحد است.
به درخواست، ما میتوانیم تمام مدارک لازم، از جمله گواهیهای مبدا/انطباق و سایر مدارک صادراتی مورد نیاز را ارائه دهیم.
برای کالاهای موجود در انبار، هدف ما تحویل در عرض ۱ تا ۳ روز پس از تأیید پرداخت است. کالاهایی که زمان تحویل مشخصی دارند، طبق برنامه اعلام شده تحویل داده خواهند شد.
ما پرداخت 100% T/T (انتقال تلگرافی) را قبل از ارسال قبول میکنیم. برای کالاهایی با زمان تحویل، 30% پیشپرداخت لازم است و 70% باقیمانده قبل از ارسال پرداخت میشود. برای انتقالات RMB، لطفاً اگر نمایندهای در چین دارید با ما تماس بگیرید.
ما یک سال گارانتی استاندارد برای تمام کالاهای جدید و اصلی ارائه میدهیم. اگر به گارانتی تمدید شده نیاز دارید، لطفاً برای جزئیات هزینه اضافی با ما تماس بگیرید.
رضایت شما برای ما مهم است. اگر نیاز به بازگرداندن کالا دارید، باید این کار ظرف ۳۰ روز از تاریخ سفارش انجام شود. محصول باید استفاده نشده، باز نشده و در بستهبندی اصلی خود با تمام لوازم جانبی همراه باشد. بازپرداختها ظرف ۵-۷ روز کاری پس از دریافت کالای بازگردانده شده پردازش میشوند. لطفاً توجه داشته باشید که هزینههای حمل و نقل و هزینههای مرتبط قابل بازپرداخت نیستند.