{"product_id":"epro-con011-916-200-eddy-current-signal-converter","title":"Epro CON011\/916-200 Eddy Current Signal Converter","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCON011\/916-200\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom EPRO (Emerson) is a precision signal conditioning module designed for eddy current-based proximity and vibration measurement systems used in rotating machinery diagnostics. It converts raw probe outputs into standardized analog signals for condition monitoring systems in high-reliability industrial environments.\u003c\/p\u003e\n\u003cp\u003eEngineered for turbine trains, compressors, pumps, and other high-speed rotating assets, this converter ensures stable signal integrity under wide temperature ranges and mechanical stress conditions.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCON011\/916-200\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEPRO (Emerson)\u003cbr\u003e\u003cstrong\u003eDevice Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEddy Current Signal Converter \/ Proximity Signal Conditioner\u003cbr\u003e\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGermany\u003c\/p\u003e\n\u003ch4\u003eElectrical Characteristics\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSupply Voltage: typically −23 V to −32 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOutput Signal Range:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e−4 V to −20 V (standard configuration)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e−2 V to −18 V (alternative scaling variant)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eLow-noise analog conditioning for vibration and displacement channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStable excitation supply for proximity probe systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eDynamic Performance\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eFrequency Response (−3 dB): 0 to 20 kHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSignal Rise Time: \u0026lt; 15 µs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOptimized for high-speed shaft vibration measurement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePhase-stable conversion for diagnostic accuracy\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSensor Compatibility\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePR6422\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePR6423\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePR6424\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePR6425 (requires extended range configuration)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePR6426\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnvironmental \u0026amp; Mechanical\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: −30 °C to +100 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShock Resistance: up to 5 g @ 60 Hz (25 °C reference)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProtection Rating: IP65 (dust-tight, water jet resistant enclosure)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHousing Material: Die-cast aluminum alloy (GD-AlSi9Cu3)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMounting: 4 × M5 screws (industrial panel or field installation)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: 600 g\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFunctional Role in Monitoring Systems\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eConverts eddy current probe signals into standardized voltage outputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnables continuous shaft displacement and vibration monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrates with turbine protection and condition monitoring platforms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports high-frequency transient detection in rotating equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication Areas\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSteam and gas turbine vibration monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompressor shaft displacement analysis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHydro turbine bearing condition diagnostics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial pump and fan predictive maintenance systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-speed rotor dynamic measurement systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eOperational Considerations\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMust be paired with compatible EPRO PR64xx probe systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIncorrect excitation voltage may cause signal drift or failure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExtended range configuration required for PR6425 applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIP65 rating protects against dust ingress and water jets but not immersion\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Can this converter operate with non-EPRO sensors?\u003c\/strong\u003e\u003cbr\u003eNo, it is designed specifically for EPRO PR6422–PR6426 eddy current probe systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Is the device suitable for outdoor installation?\u003c\/strong\u003e\u003cbr\u003eYes, provided it is installed within IP65-compliant enclosures and within temperature limits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Does it support high-frequency vibration analysis?\u003c\/strong\u003e\u003cbr\u003eYes, it supports up to 20 kHz bandwidth, suitable for high-speed turbomachinery diagnostics.\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":43225910837338,"sku":"CON011\/916-200","price":178.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/PR6423000-1111_59c0578f-c577-4cd6-bda4-4ca033f79511.jpg?v=1776407689","url":"https:\/\/www.plcmasters.com\/fa\/products\/epro-con011-916-200-eddy-current-signal-converter","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}