توضیحات
Product Summary
The PR6423/004-000 from EPRO (Emerson) is an 8 mm eddy current proximity probe used for continuous monitoring of shaft dynamics in rotating machinery. It is designed for precise non-contact measurement of vibration, axial/radial displacement, and rotor position in high-speed industrial equipment.
The probe is optimized for long-term stability in harsh mechanical and thermal environments, typically deployed in turbine trains, compressors, pumps, and gearbox systems where reliable shaft condition data is critical.
Technical Specifications
Model: PR6423/004-000
Manufacturer: EPRO (Emerson)
Sensor Type: Eddy Current Displacement / Proximity Probe
Country of Origin: Germany
Measurement Characteristics
-
Nominal Measurement Range: 2 mm (80 mils) linear displacement window
-
Initial Air Gap: ~0.5 mm (nominal installation gap)
-
Sensitivity (Scale Factor): 8 V/mm ±5% (0–45 °C reference range)
-
Linearity Deviation: ±0.025 mm within calibrated range
-
Minimum Shaft Diameter: ≥25 mm recommended
-
Target Material: Ferromagnetic steel (e.g., AISI 4140 or equivalent)
Physical Construction
-
Probe Tip Diameter: 8 mm
-
Probe Body Design: Compact cylindrical stainless steel housing
-
Installation Thread: Standard industrial probe mounting format (compatible with EPRO extension systems)
Environmental Performance
-
Operating Temperature: −35 °C to +180 °C
-
Protection Rating: IP66 (dust-tight and high-pressure water jet resistant)
-
Standard Compliance: IEC 60529 environmental sealing classification
-
High thermal stability for turbine casing and bearing housing installations
System Integration Notes
-
Designed for use with EPRO signal conditioners (e.g., CON011 / CON021 series)
-
Requires matching extension cable and driver electronics for calibrated output
-
Output characteristics depend on matched probe-converter system calibration
-
Best performance achieved within defined linear operating gap range
Application Scenarios
-
Steam and gas turbine shaft vibration monitoring
-
Compressor rotor radial displacement measurement
-
Hydro turbine axial position tracking
-
Industrial gearbox bearing condition analysis
-
Pump shaft eccentricity and alignment monitoring
Engineering Considerations
-
Measurement accuracy depends on ferromagnetic target material properties
-
Limited to short displacement range (2 mm), unsuitable for large stroke motion
-
Calibration accuracy specified at 0–45 °C; drift may increase outside range
-
Requires stable mechanical mounting to avoid signal distortion
FAQ
Q1: Can this probe measure non-metal surfaces?
No. It requires a conductive ferromagnetic target for eddy current induction.
Q2: Is it compatible with all signal converters?
It is optimized for EPRO CON-series drivers; compatibility with other systems requires verification.
Q3: Can it be used in high-temperature turbine zones?
Yes, up to 180 °C, provided extension cabling and converter are rated accordingly.
ویژگیها
ما سفارشهای عمده را میپذیریم و حداقل تعداد سفارش فقط یک واحد است.
به درخواست، ما میتوانیم تمام مدارک لازم، از جمله گواهیهای مبدا/انطباق و سایر مدارک صادراتی مورد نیاز را ارائه دهیم.
برای کالاهای موجود در انبار، هدف ما تحویل در عرض ۱ تا ۳ روز پس از تأیید پرداخت است. کالاهایی که زمان تحویل مشخصی دارند، طبق برنامه اعلام شده تحویل داده خواهند شد.
ما پرداخت 100% T/T (انتقال تلگرافی) را قبل از ارسال قبول میکنیم. برای کالاهایی با زمان تحویل، 30% پیشپرداخت لازم است و 70% باقیمانده قبل از ارسال پرداخت میشود. برای انتقالات RMB، لطفاً اگر نمایندهای در چین دارید با ما تماس بگیرید.
ما یک سال گارانتی استاندارد برای تمام کالاهای جدید و اصلی ارائه میدهیم. اگر به گارانتی تمدید شده نیاز دارید، لطفاً برای جزئیات هزینه اضافی با ما تماس بگیرید.
رضایت شما برای ما مهم است. اگر نیاز به بازگرداندن کالا دارید، باید این کار ظرف ۳۰ روز از تاریخ سفارش انجام شود. محصول باید استفاده نشده، باز نشده و در بستهبندی اصلی خود با تمام لوازم جانبی همراه باشد. بازپرداختها ظرف ۵-۷ روز کاری پس از دریافت کالای بازگردانده شده پردازش میشوند. لطفاً توجه داشته باشید که هزینههای حمل و نقل و هزینههای مرتبط قابل بازپرداخت نیستند.