توضیحات
Product Description
The Foxboro N0309YK is a precision 2-wire, isolated Resistance-to-Voltage (R/V) converter designed to translate 4–20 mA current-loop signals into 0–10 VDC voltage outputs. This module enables seamless integration between current-based field transmitters and voltage-based PLC or DCS input cards, providing accurate signal conditioning for process-control applications.
Engineered for industrial environments, the N0309YK is loop-powered, eliminating the need for an external power supply, and housed in a rugged NEMA 4X enclosure for protection against dust, moisture, and corrosive atmospheres. Its high accuracy (±0.25% of span) and linearity (±0.1%) ensure reliable performance in pressure, temperature, flow, and level measurement systems. DIN-rail or panel mounting options provide installation flexibility.
Key Features
-
Converts 4–20 mA input signals to 0–10 VDC output
-
2-wire loop-powered design for simplified installation
-
NEMA 4X enclosure for outdoor and corrosive environments
-
High accuracy: ±0.25% of span, linearity ±0.1%
-
Full electrical isolation between input and output
-
Reverse polarity protection built-in
-
Mounting options: DIN rail or panel
-
CE, UL, and CSA certified
Technical Specifications
Input
-
Signal Type: 4–20 mA current loop
-
Field-Selectable Spans: 0–100 mV to 0–10 VDC
-
Special-Order Spans: 0–5 V, 0–15 V, 0–30 V, 0–60 V, 0–120 V
Output
-
Signal Type: 0–10 VDC
-
Accuracy: ±0.25% of span
-
Linearity: ±0.1%
Electrical & Protection
-
Power Supply: Loop-powered (2-wire)
-
Isolation: Full input-to-output isolation
-
Reverse Polarity Protection: Yes
-
Low power consumption
Environmental
-
Operating Temperature: –40°C to +85°C
-
Enclosure: NEMA 4X (dustproof, waterproof, corrosion-resistant)
-
Suitable for: Outdoor, corrosive, and industrial environments
Mechanical
-
Dimensions: 10 × 5 × 2 cm
-
Weight: 0.5kg
-
Mounting: DIN rail or panel
Applications
-
Signal conversion for PLC and DCS systems
-
Conditioning 4–20 mA loops for pressure, temperature, flow, and level measurement
-
Industrial automation in harsh environments
-
Upgrading legacy 4–20 mA systems to voltage-input devices
-
Corrosive, outdoor, and high-reliability installations
FAQ
Q: Does the N0309YK require an external power source?
A: No, it is loop-powered and draws power directly from the 4–20 mA loop.
Q: What is the maximum output voltage?
A: The module converts to 0–10 VDC with high accuracy.
Q: Can it operate in outdoor or corrosive environments?
A: Yes, the NEMA 4X enclosure ensures protection against dust, moisture, and corrosive atmospheres.
Q: Are there alternative span configurations?
A: Yes, field-selectable spans and special-order voltage ranges up to 120 VDC are available.
ویژگیها
ما سفارشهای عمده را میپذیریم و حداقل تعداد سفارش فقط یک واحد است.
به درخواست، ما میتوانیم تمام مدارک لازم، از جمله گواهیهای مبدا/انطباق و سایر مدارک صادراتی مورد نیاز را ارائه دهیم.
برای کالاهای موجود در انبار، هدف ما تحویل در عرض ۱ تا ۳ روز پس از تأیید پرداخت است. کالاهایی که زمان تحویل مشخصی دارند، طبق برنامه اعلام شده تحویل داده خواهند شد.
ما پرداخت 100% T/T (انتقال تلگرافی) را قبل از ارسال قبول میکنیم. برای کالاهایی با زمان تحویل، 30% پیشپرداخت لازم است و 70% باقیمانده قبل از ارسال پرداخت میشود. برای انتقالات RMB، لطفاً اگر نمایندهای در چین دارید با ما تماس بگیرید.
ما یک سال گارانتی استاندارد برای تمام کالاهای جدید و اصلی ارائه میدهیم. اگر به گارانتی تمدید شده نیاز دارید، لطفاً برای جزئیات هزینه اضافی با ما تماس بگیرید.
رضایت شما برای ما مهم است. اگر نیاز به بازگرداندن کالا دارید، باید این کار ظرف ۳۰ روز از تاریخ سفارش انجام شود. محصول باید استفاده نشده، باز نشده و در بستهبندی اصلی خود با تمام لوازم جانبی همراه باشد. بازپرداختها ظرف ۵-۷ روز کاری پس از دریافت کالای بازگردانده شده پردازش میشوند. لطفاً توجه داشته باشید که هزینههای حمل و نقل و هزینههای مرتبط قابل بازپرداخت نیستند.