{"product_id":"yokogawa-fc311-s1-bus-station-module","title":"Yokogawa FC311 S1 Bus Station Module","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa FC311-S1\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eis a high-performance central processing unit module designed for Bus Station installations in CENTUM VP and CS 3000 systems. As the core processor of the Bus Station, it executes real-time control, coordinates I\/O communication, and provides reliable network interfaces. The module supports redundant CPU configurations, enabling hot-swappable operation without interrupting ongoing processes, making it ideal for mission-critical, 24\/7 industrial environments.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eExecutes PID and advanced regulatory control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports sequential logic and batch process control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInterfaces with AI, AO, DI, DO, and specialty I\/O nodes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnects to Human Interface Stations (HIS) and Engineering Workstations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCommunicates over V-net and V-net\/IP networks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports online download of control logic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIncludes self-diagnostics for CPU load, memory, communication, and hardware health\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProvides system-wide time synchronization\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral Parameters\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eFC311-S1\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart \/ Order Number\u003c\/td\u003e\n\u003ctd\u003eAS-S9391AT-0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eFCU Processor (Bus Station CPU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Systems\u003c\/td\u003e\n\u003ctd\u003eCENTUM VP \/ CS 3000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eAFV30, AFV40, A2FV50, A2FV70 Bus Station\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eReal-time control and system communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eYokogawa Electric Corporation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-speed scan cycles for complex process control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports hundreds of control loops and thousands of I\/O points\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDeterministic execution ensures stable process automation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRedundant CPU option enables seamless switchover in critical applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical \u0026amp; Environmental Conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eProvided by Bus Station (typically 24 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to 55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-20°C to 85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5–95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMI \/ EMC\u003c\/td\u003e\n\u003ctd\u003eIndustrial-grade compliance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003ePassive convection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Parameters\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.85 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eBus Station slot installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConstruction\u003c\/td\u003e\n\u003ctd\u003eIndustrial-grade PCB with metal shielding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCentral CPU for Bus Station-based process control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eContinuous and batch process automation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower plant and energy system automation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOil, gas, petrochemical, and refining industries\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-availability systems with redundant CPU configurations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e24\/7 industrial operation environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ (Frequently Asked Questions)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Does the FC311-S1 support online hot-swapping?\u003c\/strong\u003e\u003cbr\u003eA1: Yes, when configured in redundant CPU mode, it allows hot-swapping without interrupting the control process.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: How many I\/O points can it handle?\u003c\/strong\u003e\u003cbr\u003eA2: Depending on system configuration, it can support thousands of I\/O points for large-scale control applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Which Bus Station bases are compatible?\u003c\/strong\u003e\u003cbr\u003eA3: Compatible with AFV30, AFV40, A2FV50, and A2FV70 Bus Station bases.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Does the module provide network time synchronization?\u003c\/strong\u003e\u003cbr\u003eA4: Yes, it ensures system-wide time synchronization for consistent process data.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: Are there similar models for comparison?\u003c\/strong\u003e\u003cbr\u003eA5: The FC311-S2 offers higher processing capacity and additional redundancy options, suitable for ultra-large process control systems.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":42892881526874,"sku":"FC311 S1","price":264.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/FC311S12.jpg?v=1770349469","url":"https:\/\/www.plcmasters.com\/fa\/products\/yokogawa-fc311-s1-bus-station-module","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}