{"product_id":"emerson-ovation-5x00622g01-rtd-input-module","title":"Emerson Ovation 5X00622G01 RTD Input Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEmerson Ovation 5X00622G01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance 16-channel RTD Input Module engineered for Ovation Distributed Control Systems (DCS). It delivers precise temperature measurement by converting resistance-based RTD signals into high-resolution digital data, suitable for advanced process monitoring and control.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5X00622G01\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003e16-Channel RTD Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e16 independent RTD inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported RTD Types\u003c\/td\u003e\n\u003ctd\u003ePt100, Pt1000, Ni120, Cu10 (configurable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003e-200°C to +850°C (depends on RTD type)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eChannel-to-channel \u0026amp; channel-to-ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling Rate\u003c\/td\u003e\n\u003ctd\u003eUp to 1 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHot Swap\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5–95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e240 mm × 115 mm × 35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.36 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMulti-channel capability for dense temperature monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-precision measurement with ±0.1% full-scale accuracy\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBroad RTD compatibility (Pt, Ni, Cu sensors)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRobust isolation to prevent electrical interference\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHot-swappable design for uninterrupted system operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBuilt-in diagnostics for sensor integrity and fault detection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module is ideal for industries requiring accurate temperature monitoring, including power generation, oil \u0026amp; gas, chemical processing, water treatment, and other critical process environments.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this module support both Pt100 and Ni120 sensors simultaneously?\u003c\/strong\u003e\u003cbr\u003eA: The module can be configured to support multiple RTD types per installation, but each channel must be assigned a compatible RTD type.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is hot-swap replacement possible during live operations?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5X00622G01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports hot-swapping without shutting down the DCS.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does this module compare to 5X00620G01?\u003c\/strong\u003e\u003cbr\u003eA: Both modules offer multi-channel RTD input, but 5X00622G01 provides higher resolution (16-bit) and wider isolation per channel, enhancing measurement stability in electrically noisy environments.\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":43061896052826,"sku":"5X00622G01","price":284.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/5X00622G012.jpg?v=1773732284","url":"https:\/\/www.plcmasters.com\/fr\/products\/emerson-ovation-5x00622g01-rtd-input-module","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}