{"product_id":"foxboro-873cc-biyfgz-conductivity-analyzer-electrochemical","title":"Foxboro 873CC-BIYFGZ Conductivity Analyzer Electrochemical","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e873CC-BIYFGZ\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a precision electrochemical analyzer from Foxboro’s 873CC family, developed for continuous monitoring of liquid conductivity and resistivity in industrial processes. It is designed to provide stable, repeatable measurements for water quality control, including ultra-pure and process water applications.\u003c\/p\u003e\n\u003cp\u003eThis unit supports dual-channel sensor input, allowing simultaneous measurement at two independent points. With integrated temperature compensation and multiple calculation modes, it delivers reliable results across varying process conditions.\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e873CC-BIYFGZ\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis commonly deployed in environments where accurate ionic measurement is critical to system performance and product quality.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurement Capabilities\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eModel:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e873CC-BIYFGZ\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMeasurement Type: Contacting conductivity and resistivity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMeasurement Range:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e0.00 μS\/cm to 20.00 mS\/cm (standard range)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfigurable lower ranges (e.g., 0–100 μS\/cm for high-purity water)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eMeasurement Modes:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eConductivity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResistivity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRemoval rate\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAbsolute value\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eSensor Inputs: Dual-channel (2 independent sensors)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTemperature Compensation: Automatic via RTD (100 Ω) or external sensor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDisplay \u0026amp; User Interface\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDisplay Type: 4-digit LED\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVisibility: High contrast for low-light conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperator Interface: Front-panel keypad for configuration and calibration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStatus Indication: Alarm and process status via display and relay outputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication \u0026amp; Outputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eAnalog Output: 4–20 mA (process signal transmission)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRelay Outputs:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e2 configurable alarm relays (NO\/NC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRating: up to 5 A at 125 VAC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eDigital Communication (optional):\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRS-485\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eModbus protocol support\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Characteristics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePower Supply: 100–240 VAC (universal input)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFrequency: 50\/60 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower Consumption: approx. 102 W max\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProtection: Internal fuse (150 mA slow-blow typical)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical \u0026amp; Environmental\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: –10°C to +50°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnclosure Options:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eGeneral-purpose plastic housing (indoor use)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMetal enclosure with NEMA 4X protection (corrosion-resistant, outdoor use)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eMounting Options:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePanel mounting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWall mounting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePipe mounting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eProtection Rating: Up to NEMA 4X (metal version)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: 1.85 lbs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCE certified\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRoHS compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned to meet industrial water quality monitoring standards\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication Scenarios\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e873CC-BIYFGZ\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis used in processes requiring accurate monitoring of liquid conductivity:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSemiconductor and ultrapure water systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePharmaceutical production and clean utilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFood and beverage processing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower plant boiler and cooling water monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial and municipal water treatment systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this analyzer measure two process streams simultaneously?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it supports dual-sensor input, allowing monitoring of two independent measurement points.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What types of sensors are compatible?\u003c\/strong\u003e\u003cbr\u003eA: It is designed for contacting conductivity sensors and supports RTD temperature inputs for compensation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is it suitable for outdoor installation?\u003c\/strong\u003e\u003cbr\u003eA: Yes, when equipped with the metal enclosure, it meets NEMA 4X requirements for outdoor and corrosive environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does it support digital communication protocols?\u003c\/strong\u003e\u003cbr\u003eA: Optional RS-485 and Modbus communication are available depending on configuration.\u003c\/p\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":43210226237530,"sku":"873CC-BIYFGZ","price":177.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/873CC-BIYFGZ.jpg?v=1776073184","url":"https:\/\/www.plcmasters.com\/fr\/products\/foxboro-873cc-biyfgz-conductivity-analyzer-electrochemical","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}