{"product_id":"yokogawa-atf9s-00-terminal-board","title":"Yokogawa ATF9S-00 Terminal Board","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa ATF9S‑00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-reliability terminal board designed for field I\/O (FIO) systems in CENTUM VP and CENTUM CS3000 environments. It provides a secure interface between field devices and Yokogawa I\/O modules, enabling precise signal routing and stable operation in industrial process plants. This terminal board is engineered for continuous operation in oil \u0026amp; gas, petrochemical, power generation, and water treatment facilities.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eField-side interface for analog and digital I\/O signals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible with AI, AO, DI, DO modules depending on system configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eScrew-terminal design for secure and easy field connections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eElectrical isolation between field wiring and system\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh noise immunity for industrial environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports integration into distributed I\/O architectures and local I\/O cabinets\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eATF9S‑00\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eTerminal Board (Field Wiring Interface)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eCENTUM VP, CENTUM CS3000, FIO subsystem\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eField signal termination and routing for Yokogawa I\/O modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Characteristics\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Signals\u003c\/td\u003e\n\u003ctd\u003eAnalog Input\/Output (AI\/AO), Digital Input\/Output (DI\/DO) depending on connected module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eFull galvanic separation between field wiring and system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise Immunity\u003c\/td\u003e\n\u003ctd\u003eHigh, industrial-grade design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring Method\u003c\/td\u003e\n\u003ctd\u003eScrew terminals (M3\/M4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Path\u003c\/td\u003e\n\u003ctd\u003eDirect routing to I\/O module via dedicated cable or backplane connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical \u0026amp; Environmental\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eScrew terminals, industrial grade\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePCB Construction\u003c\/td\u003e\n\u003ctd\u003eIndustrial-grade PCB with protective coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003ePanel or rack-mounted in I\/O cabinets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eStandard Yokogawa terminal board size\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e−20 °C to +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5–95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration \u0026amp; EMC\u003c\/td\u003e\n\u003ctd\u003eHigh resistance to industrial vibration and electrical noise\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eATF9S‑00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis used to terminate and route signals from sensors, transmitters, switches, and actuators to Yokogawa I\/O modules. It ensures reliable signal transfer in distributed remote I\/O nodes or centralized local I\/O cabinets. Ideal for industrial automation applications requiring stable, low-noise, and isolated field connections.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this terminal board handle both analog and digital signals?\u003c\/strong\u003e\u003cbr\u003eA: Yes, depending on the connected I\/O modules, it can terminate AI, AO, DI, or DO signals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What mounting options are available?\u003c\/strong\u003e\u003cbr\u003eA: Supports both panel and rack mounting inside I\/O cabinets.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is it suitable for high-noise industrial environments?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it features electrical isolation and noise-resistant design.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Are there similar models for comparison?\u003c\/strong\u003e\u003cbr\u003eA: Models ATF9S‑01 and ATF9S‑10 offer similar functionality with variations in terminal layout and module support.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":42894674526298,"sku":"ATF9S-00","price":264.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/ATF9S-001.jpg?v=1770363132","url":"https:\/\/www.plcmasters.com\/fr\/products\/yokogawa-atf9s-00-terminal-board","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}