Deskripsi
Product Description
The KL3106X1-BA1 is an intrinsically safe (I.S.) analog input CHARM module from Emerson, specifically designed for thermocouple signal acquisition in DeltaV systems. It allows precise and reliable temperature measurement in hazardous areas while maintaining compliance with global safety standards.
This compact CHARM module integrates directly into DeltaV racks, providing single-channel thermocouple input with low CHARM bus power consumption. The terminal block key position BA1 ensures correct wiring and installation, while the rugged design withstands vibration, shock, and airborne contaminants. No calibration is required, and the module has no user-serviceable parts, making it maintenance-free.
Technical Specifications
-
Model: KL3106X1-BA1
-
Module Type: Intrinsically Safe Analog Input (AI) CHARM
-
Signal Type: Thermocouple input (supports multiple types)
-
Safety Type: Intrinsically Safe (I.S.)
-
CHARM Bus Power: +6.3 VDC at minimal current
-
Field Circuit Power: +24 VDC, ~23 mA
-
Channels: Single-channel
-
Terminal Block Key Position: BA1
-
Operating Temperature: –40 °C to +70 °C
-
Humidity: 5–95% RH, non-condensing
-
Shock Resistance: 10 g, half-sine wave, 11 ms
-
Vibration: 2–13.2 Hz: 1 mm peak-to-peak; 13.2–150 Hz: 0.7 g
-
Airborne Contaminants: ISA-S71.04-1985 Class G3
Safety & Compliance
-
Hazardous Atmosphere Ratings:
-
II 3(1) G Ex ec [ia Ga] IIC Gc
-
II 3G (1D) Ex ec [ia IIIC Da] IIC Gc
-
Class I, Division 2, Groups A–D
-
Zone 2 AEx ec [ia Ga/IIIC Da] IIC Gc
-
Certifications: ATEX, IECEx, FM, UKEX
-
Installation Note: Do not insert or remove while energized unless area is confirmed non-hazardous
Key Highlights
-
Single-channel thermocouple input for accurate temperature measurement
-
Intrinsically safe design suitable for hazardous environments
-
Compact CHARM form factor for seamless DeltaV system integration
-
Wide environmental tolerance: –40 °C to +70 °C, Class G3 airborne contaminants
-
Keyed terminal block BA1 ensures proper connection and installation
Applications
-
Hazardous area temperature monitoring using thermocouples
-
DeltaV systems requiring single-channel intrinsically safe analog input
-
Process plants in oil, gas, chemical, or other Zone 2 / Class I Div. 2 environments
FAQ
Q: Which thermocouple types are supported by KL3106X1-BA1?
A: The module supports standard thermocouple types (J, K, T, E, R, S, B, N) depending on configuration.
Q: Can it be used in Class I Division 2 areas?
A: Yes, it is certified for Zone 2 / Class I Div. 2 hazardous areas.
Q: Is calibration required for operation?
A: No, the module is factory-calibrated and requires no user maintenance.
Fitur
Kami menerima pesanan dalam jumlah besar dan memiliki jumlah pesanan minimum hanya satu unit.
Atas permintaan, kami dapat menyediakan semua dokumentasi yang diperlukan, termasuk Sertifikat Asal/Kesesuaian dan dokumen ekspor lain yang dibutuhkan.
Untuk barang yang tersedia, kami berusaha mengirim dalam 1-3 hari setelah konfirmasi pembayaran. Barang dengan waktu tunggu yang ditentukan akan dikirim sesuai jadwal yang telah disebutkan.
Kami menerima pembayaran 100% T/T (Telegraphic Transfer) sebelum pengiriman. Untuk barang dengan waktu tunggu, diperlukan deposit 30% di muka, dengan sisa 70% harus dibayar sebelum pengiriman. Untuk transfer RMB, silakan hubungi kami jika Anda memiliki agen di China.
Kami menawarkan garansi standar satu tahun untuk semua barang baru dan asli. Jika Anda memerlukan garansi tambahan, silakan hubungi kami untuk detail biaya tambahan.
Kepuasan Anda penting bagi kami. Jika Anda perlu mengembalikan barang, itu harus dilakukan dalam waktu 30 hari sejak tanggal pemesanan. Produk harus belum digunakan, belum dibuka, dan dalam kemasan aslinya dengan semua aksesori yang disertakan. Pengembalian dana diproses dalam waktu 5-7 hari kerja setelah kami menerima barang yang dikembalikan. Harap dicatat bahwa biaya pengiriman dan biaya terkait tidak dapat dikembalikan.