Deskripsi
Product Description
The KL3106X1-LS1 from Emerson is a single-channel analog input CHARM module engineered for thermocouple signals in DeltaV systems. Its intrinsically safe (I.S.) design ensures secure operation in hazardous environments, including Zone 2 and Class I Division 2 locations.
Featuring LS1 keyed terminals, this module prevents miswiring and simplifies installation. The compact CHARM format allows seamless integration into DeltaV racks while maintaining a minimal CHARM bus power draw. With broad environmental tolerance and robust resistance to shock, vibration, and airborne contaminants, it provides reliable temperature measurement in industrial conditions.
Technical Specifications
-
Model: KL3106X1-LS1
-
Module Type: Intrinsically Safe (I.S.) Analog Input CHARM
-
Signal Type: Thermocouple input (supports multiple types)
-
Safety Type: Intrinsically Safe (I.S.)
-
CHARM Bus Power: +6.3 VDC at minimal consumption
-
Field Circuit Power: +24 VDC, ~60 mA
-
Channels: Single-channel CHARM
-
Terminal Block Key Position: LS1
-
Operating Temperature: –40 °C to +70 °C
-
Humidity: 5–95% RH, non-condensing
-
Shock Resistance: 10 g, half-sine wave, 11 ms
-
Vibration: 2–13.2 Hz: 1 mm peak-to-peak; 13.2–150 Hz: 0.7 g
-
Airborne Contaminants: ISA-S71.04-1985 Class G3
-
Maintenance: No calibration required; no user-serviceable parts
Safety & Compliance
-
Hazardous Atmosphere Ratings:
-
II 3(1) G Ex ec [ia Ga] IIC Gc
-
II 3G (1D) Ex ec [ia IIIC Da] IIC Gc
-
Class I, Division 2, Groups A–D
-
Zone 2 AEx ec [ia Ga] IIC Gc
-
Certifications: ATEX, IECEx, FM, UKEX
-
Installation Note: Do not insert or remove while energized unless area is verified non-hazardous
Key Highlights
-
Single-channel thermocouple input for accurate temperature monitoring
-
Intrinsically safe design for hazardous area applications
-
LS1 keyed terminal block ensures proper wiring and safe installation
-
Broad environmental tolerance: –40 °C to +70 °C; resistant to shock, vibration, and Class G3 airborne contaminants
-
Compact CHARM module for seamless DeltaV system integration
Applications
-
Temperature measurement in hazardous areas using thermocouples
-
Integration into DeltaV I/O systems for process control
-
Suitable for oil, gas, chemical, and other Zone 2 / Class I Div. 2 industrial environments
FAQ
Q: Which thermocouple types are compatible with KL3106X1-LS1?
A: Supports standard thermocouples including types J, K, T, E, R, S, B, and N depending on configuration.
Q: Can this module be installed in Zone 2 locations?
A: Yes, it is certified for Zone 2 and Class I Division 2 hazardous areas.
Q: Is calibration required before operation?
A: No, the module is factory-calibrated and maintenance-free.
Fitur
Kami menerima pesanan dalam jumlah besar dan memiliki jumlah pesanan minimum hanya satu unit.
Atas permintaan, kami dapat menyediakan semua dokumentasi yang diperlukan, termasuk Sertifikat Asal/Kesesuaian dan dokumen ekspor lain yang dibutuhkan.
Untuk barang yang tersedia, kami berusaha mengirim dalam 1-3 hari setelah konfirmasi pembayaran. Barang dengan waktu tunggu yang ditentukan akan dikirim sesuai jadwal yang telah disebutkan.
Kami menerima pembayaran 100% T/T (Telegraphic Transfer) sebelum pengiriman. Untuk barang dengan waktu tunggu, diperlukan deposit 30% di muka, dengan sisa 70% harus dibayar sebelum pengiriman. Untuk transfer RMB, silakan hubungi kami jika Anda memiliki agen di China.
Kami menawarkan garansi standar satu tahun untuk semua barang baru dan asli. Jika Anda memerlukan garansi tambahan, silakan hubungi kami untuk detail biaya tambahan.
Kepuasan Anda penting bagi kami. Jika Anda perlu mengembalikan barang, itu harus dilakukan dalam waktu 30 hari sejak tanggal pemesanan. Produk harus belum digunakan, belum dibuka, dan dalam kemasan aslinya dengan semua aksesori yang disertakan. Pengembalian dana diproses dalam waktu 5-7 hari kerja setelah kami menerima barang yang dikembalikan. Harap dicatat bahwa biaya pengiriman dan biaya terkait tidak dapat dikembalikan.