Deskripsi
Overview
The IC670ALG620 module from GE Fanuc is a high-precision RTD input interface designed for Field Control systems. It supports four independent channels and is compatible with both 3-wire and 4-wire RTD sensors, including Platinum, Nickel, Nickel/Iron, and Copper types. The module converts resistance measurements into accurate temperature data for process monitoring, control applications, and industrial automation systems.
Key Features
-
Four fully isolated RTD input channels for flexible sensor integration
-
Supports 3-wire and 4-wire RTD configurations
-
Configurable measurement ranges: 0–500 Ω or 0–3000 Ω
-
Outputs in resistance (Ω), Celsius (°C), or Fahrenheit (°F) with tenths resolution
-
Built-in diagnostics for open-wire, short-circuit, overrange/underrange, and high/low alarms
-
No external loop power required, reducing installation complexity
-
Industrial-grade reliability for continuous operation
Technical Specifications
| Specification | Details |
|---|---|
| Model Number | IC670ALG620 |
| Input Channels | 4 independent RTD inputs (3-wire or 4-wire) |
| Supported RTD Types | Platinum, Nickel, Nickel/Iron, Copper |
| Resistance Ranges | 0–500 Ω, 0–3000 Ω (selectable) |
| Measurement Units | Ω, °C, °F (tenths resolution) |
| Scan Time | 210 ms (60 Hz), 230 ms (50 Hz) |
| Digital Resolution | 15-bit plus sign |
| Maximum Lead Resistance | 5 Ω per lead |
| Normal Mode Rejection | 60 dB at 50/60 Hz, 100% span |
| Temperature Sensitivity | ±0.004% of reading, ±1.5 mV/°C referred to input (0–60°C) |
| Fault Detection | Open RTD, short, underrange, overrange, high/low alarms |
| Power Requirements | Draws up to 190 mA from BIU supply, no loop power needed |
| Dimensions | 120 × 50 × 100 mm |
| Weight | 0.45 kg |
Applications
Ideal for process control systems, distributed control stations, and temperature monitoring in industrial environments where precise RTD measurements are required. It integrates seamlessly with GE Field Control systems for automated and reliable operation.
FAQ
Q: Can the module measure multiple RTD types simultaneously?
A: Yes, each channel can be individually configured for Platinum, Nickel, Nickel/Iron, or Copper RTDs.
Q: Is external power required for the RTDs?
A: No, the module does not require loop power; it draws power directly from the Bus Interface Unit.
Q: How is configuration performed?
A: The module is configured via a handheld device connected to the main Bus Interface Unit.
Fitur
Kami menerima pesanan dalam jumlah besar dan memiliki jumlah pesanan minimum hanya satu unit.
Atas permintaan, kami dapat menyediakan semua dokumentasi yang diperlukan, termasuk Sertifikat Asal/Kesesuaian dan dokumen ekspor lain yang dibutuhkan.
Untuk barang yang tersedia, kami berusaha mengirim dalam 1-3 hari setelah konfirmasi pembayaran. Barang dengan waktu tunggu yang ditentukan akan dikirim sesuai jadwal yang telah disebutkan.
Kami menerima pembayaran 100% T/T (Telegraphic Transfer) sebelum pengiriman. Untuk barang dengan waktu tunggu, diperlukan deposit 30% di muka, dengan sisa 70% harus dibayar sebelum pengiriman. Untuk transfer RMB, silakan hubungi kami jika Anda memiliki agen di China.
Kami menawarkan garansi standar satu tahun untuk semua barang baru dan asli. Jika Anda memerlukan garansi tambahan, silakan hubungi kami untuk detail biaya tambahan.
Kepuasan Anda penting bagi kami. Jika Anda perlu mengembalikan barang, itu harus dilakukan dalam waktu 30 hari sejak tanggal pemesanan. Produk harus belum digunakan, belum dibuka, dan dalam kemasan aslinya dengan semua aksesori yang disertakan. Pengembalian dana diproses dalam waktu 5-7 hari kerja setelah kami menerima barang yang dikembalikan. Harap dicatat bahwa biaya pengiriman dan biaya terkait tidak dapat dikembalikan.