Deskripsi
Overview
The Honeywell FS-SICC-1011/L3 is a high-performance shielded interconnection cable designed for Safety Instrumented Systems (SIS), Distributed Control Systems (DCS), and fire alarm networks. Engineered for reliability, this cable ensures consistent signal integrity, electrical isolation, and robust protection in demanding industrial environments.
Technical Specifications
| Specification | Details |
|---|---|
| Cable Type | Shielded twisted-pair interconnection |
| Conductors | 9 copper conductors |
| Wire Gauge | 28 AWG |
| Shield | Braided for EMI/RFI protection |
| Voltage Rating | Up to 300 V |
| Conductor Resistance | 5.2 Ω/km at 20 °C |
| Insulation Resistance | ≥ 500 MΩ/km |
| Jacket Material | Flame-retardant PVC |
| Connector Type | D-sub connectors at each end |
| Standard Length | 3 m (9.8 ft), custom lengths available |
| Operating Temperature | -20 °C to +60 °C |
| Storage Temperature | -40 °C to +80 °C |
| Compliance | Honeywell SIS/DCS standards, NFPA fire safety requirements |
| Weight | 0.2 kg |
Key Features
-
Shielded design minimizes electromagnetic interference.
-
Flame-retardant jacket provides enhanced safety for fire alarm applications.
-
Electrical isolation ensures safe testing and commissioning of live loops.
-
Durable construction resists oils, chemicals, and mechanical stress.
-
Compatible with Honeywell controllers, I/O modules, and Field Termination Assemblies (FTA).
Applications
-
Safety Instrumented Systems (SIS): Reliable connection between safety controllers and field devices.
-
Distributed Control Systems (DCS): Stable interconnection for process automation networks.
-
Fire alarm systems: NFPA-compliant interconnection between panels and sensors.
-
Industrial automation: Oil & gas, chemical plants, and manufacturing environments requiring shielded cabling.
FAQ
Q: Can this cable be customized in length?
A: Yes, lengths beyond the standard 3 m can be configured upon request.
Q: Is the cable suitable for high-voltage applications?
A: It is rated up to 300 V; higher voltage applications require alternative specification cables.
Q: How does this differ from FS-SICC-1010 series cables?
A: The FS-SICC-1011/L3 provides enhanced EMI shielding and a flame-retardant jacket, making it more suitable for SIS and fire alarm systems.
Fitur
Kami menerima pesanan dalam jumlah besar dan memiliki jumlah pesanan minimum hanya satu unit.
Atas permintaan, kami dapat menyediakan semua dokumentasi yang diperlukan, termasuk Sertifikat Asal/Kesesuaian dan dokumen ekspor lain yang dibutuhkan.
Untuk barang yang tersedia, kami berusaha mengirim dalam 1-3 hari setelah konfirmasi pembayaran. Barang dengan waktu tunggu yang ditentukan akan dikirim sesuai jadwal yang telah disebutkan.
Kami menerima pembayaran 100% T/T (Telegraphic Transfer) sebelum pengiriman. Untuk barang dengan waktu tunggu, diperlukan deposit 30% di muka, dengan sisa 70% harus dibayar sebelum pengiriman. Untuk transfer RMB, silakan hubungi kami jika Anda memiliki agen di China.
Kami menawarkan garansi standar satu tahun untuk semua barang baru dan asli. Jika Anda memerlukan garansi tambahan, silakan hubungi kami untuk detail biaya tambahan.
Kepuasan Anda penting bagi kami. Jika Anda perlu mengembalikan barang, itu harus dilakukan dalam waktu 30 hari sejak tanggal pemesanan. Produk harus belum digunakan, belum dibuka, dan dalam kemasan aslinya dengan semua aksesori yang disertakan. Pengembalian dana diproses dalam waktu 5-7 hari kerja setelah kami menerima barang yang dikembalikan. Harap dicatat bahwa biaya pengiriman dan biaya terkait tidak dapat dikembalikan.