{"product_id":"yokogawa-ssc60d-f2542-node-interface-module","title":"Yokogawa SSC60D-F2542 Node Interface Module","description":"\u003carticle\u003e\n\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa SSC60D‑F2542\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance Node Interface Module (NIM) designed for the CENTUM VP and ProSafe‑RS systems. It serves as the communication master for a Field I\/O (FIO) node, handling all data exchange between the controller (FCU) and I\/O modules installed on the baseplate. The module supports redundant operation and hot-swap replacement, ensuring continuous and reliable operation in demanding industrial environments.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eManages communication between the controller and all FIO modules in a node\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports dual-redundant NIM configuration for high system availability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProvides module diagnostics, health monitoring, and node status reporting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eControls I\/O scan timing, synchronization, and data refresh cycles\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHot-swappable in redundant systems to minimize downtime\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFully compatible with Yokogawa FIO module series\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCommunication Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSupported Networks\u003c\/strong\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eESB Bus (Enhanced Serial Bus)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVnet\/IP (optional, depending on module variant)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTransmission Speed\u003c\/strong\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eESB: 128 Mbps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVnet\/IP (if supported): 1 Gbps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Mode\u003c\/strong\u003e: Single or redundant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum I\/O Modules per Node\u003c\/strong\u003e: Up to 16\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnector Types\u003c\/strong\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eESB: Shielded twisted pair\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVnet\/IP: RJ‑45 Ethernet (if applicable)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eProvided by FIO baseplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5–8 W (varies by hardware revision)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Scan Cycle\u003c\/td\u003e\n\u003ctd\u003e1–10 ms (deterministic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Refresh Rate\u003c\/td\u003e\n\u003ctd\u003eHigh-speed cyclic communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Error Detection\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Fault Detection\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus and Power Monitoring\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eBus interface and internal circuit isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0–50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e–20–70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5–95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC Compliance\u003c\/td\u003e\n\u003ctd\u003eIndustrial-grade noise immunity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e8.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSSC60D‑F2542\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis widely used in:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCentral control system (CENTUM VP) Field I\/O management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafety control system (ProSafe-RS) communication nodes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRedundant I\/O networks and high-availability industrial automation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this module support hot-swapping?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the SSC60D‑F2542 supports hot-swap replacement in redundant systems to maintain continuous operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many I\/O modules can one node support?\u003c\/strong\u003e\u003cbr\u003eA: Up to 16 FIO modules per node in standard configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the communication speed of SSC60D modules?\u003c\/strong\u003e\u003cbr\u003eA: ESB bus operates at 128 Mbps, while Vnet\/IP (if available) supports 1 Gbps.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is it compatible with other FIO modules?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it is fully compatible with the complete Yokogawa FIO module series.\u003c\/p\u003e\n\u003c\/article\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":42877909499994,"sku":"SSC60D-F2542","price":264.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/YokogawaSNB10D-225CU2N_c70c5c04-dd0f-4904-a364-19d3e7a7fa5f.jpg?v=1770203583","url":"https:\/\/www.plcmasters.com\/id\/products\/yokogawa-ssc60d-f2542-node-interface-module","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}