{"product_id":"allen-bradley-1756-it6i-controllogix-thermocouple-input-module","title":"Modulo di ingresso termocoppia Allen-Bradley 1756-IT6I ControlLogix","description":"\u003ch1 class=\"PDq2pG_selectionAnchorContainer\"\u003eModulo di ingresso termocoppia Allen-Bradley 1756-IT6I ControlLogix\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp\u003eIl\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1756-IT6I\u003c\/strong\u003e, anche catalogato come\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1756-IT6I\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodulo di ingresso analogico per termocoppie, serve come dedicato\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emodulo di ingresso temperatura ControlLogix\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eutilizzato per eseguire l’acquisizione isolata di segnali termocoppia e millivolt nei sistemi backplane ControlLogix. Configurato per la conversione diretta di segnali EMF a basso livello, il\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1756-IT6I (modulo ingresso termocoppia 1756-IT6I)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efornisce sei percorsi di misura elettricamente isolati con compensazione CJC interna per la correzione del riferimento di temperatura.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eScomposizione suffisso \u0026amp; matrice modello\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e1756\u003c\/strong\u003e: piattaforma I\/O chassis ControlLogix\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIT6\u003c\/strong\u003e: struttura di ingresso termocoppia \/ millivolt a 6 punti\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eI\u003c\/strong\u003e: architettura di ingresso isolato individualmente\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\/I o A\u003c\/strong\u003e: identificatore revisione hardware (non completamente specificato nel dataset)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNon sono definite ulteriori varianti funzionali nei dati forniti.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eSpecifiche hardware\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParametro\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecifiche\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModello\u003c\/td\u003e\n\u003ctd\u003e1756-IT6I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarca\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeso\u003c\/td\u003e\n\u003ctd\u003e1,38 libbre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperatura di esercizio\u003c\/td\u003e\n\u003ctd\u003e0 a 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConsumo energetico\u003c\/td\u003e\n\u003ctd\u003eMax 4,3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumero di ingressi\u003c\/td\u003e\n\u003ctd\u003e6 canali termocoppia\/mV isolati\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTermocoppie supportate\u003c\/td\u003e\n\u003ctd\u003eB, C, E, J, K, N, R, S, T, L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTipo di ingresso\u003c\/td\u003e\n\u003ctd\u003eTermocoppia \/ millivolt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRisoluzione\u003c\/td\u003e\n\u003ctd\u003e16 bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntervallo di ingresso\u003c\/td\u003e\n\u003ctd\u003e-12 a 78 mV (modalità in virgola mobile)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensore CJC\u003c\/td\u003e\n\u003ctd\u003e1 canale interno di compensazione giunzione fredda\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorrente backplane (5 VDC)\u003c\/td\u003e\n\u003ctd\u003e250 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorrente backplane (24 VDC)\u003c\/td\u003e\n\u003ctd\u003e125 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTempo di scansione modulo\u003c\/td\u003e\n\u003ctd\u003eDa 10 ms a 50 ms a seconda del formato dati\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFormato dati\u003c\/td\u003e\n\u003ctd\u003eIntero (complemento a 2), virgola mobile IEEE a 32 bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolamento\u003c\/td\u003e\n\u003ctd\u003eIsolamento tra canali\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlocchi terminali\u003c\/td\u003e\n\u003ctd\u003e1756-TBNH, 1756-TBSH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterfaccia Backplane\u003c\/td\u003e\n\u003ctd\u003eBus chassis ControlLogix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificazioni\u003c\/td\u003e\n\u003ctd\u003eUL, CE, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eComportamento deterministico di acquisizione termocoppie sul backplane ControlLogix\u003c\/h3\u003e\n\u003cp\u003eIl 1756-IT6I esegue il condizionamento del segnale basato su sigma-delta prima del trasferimento dati sul backplane ControlLogix. I segnali EMF delle termocoppie e gli ingressi in millivolt vengono digitalizzati per canale e mappati in rappresentazioni intere o in virgola mobile IEEE a 32 bit a seconda della configurazione.\u003c\/p\u003e\n\u003cp\u003eL'isolamento del canale garantisce domini di misura indipendenti, prevenendo l'interazione dei loop di terra tra le giunzioni della termocoppia. La compensazione della giunzione fredda viene eseguita utilizzando un canale di riferimento dedicato per correggere la deriva della temperatura del terminale prima della conversione di scala.\u003c\/p\u003e\n\u003cp\u003eLo scambio dati sul backplane è sincronizzato con i cicli di scansione del telaio, con un tempo minimo di scansione di 10 ms in modalità intera per l'acquisizione in millivolt e cicli estesi fino a 50 ms in modalità di conversione della temperatura in virgola mobile.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eDomande frequenti (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: È possibile mescolare tutti i tipi di termocoppia sullo stesso modulo?\u003cbr\u003eA: Sì. Ognuno dei sei canali può essere configurato individualmente per diversi tipi di termocoppia inclusi J, K, T, E, R, S, B, N, C e L.\u003c\/p\u003e\n\u003cp\u003eQ: Come influisce l'isolamento del canale sulla precisione della termocoppia?\u003cbr\u003eA: L'isolamento canale-canale elimina l'accoppiamento elettrico tra le giunzioni del sensore, riducendo l'errore di misura causato da potenziali di terra condivisi o interferenze nel loop.\u003c\/p\u003e\n\u003cp\u003eQ: Qual è l'effetto della selezione della modalità di scansione sulla velocità di aggiornamento?\u003cbr\u003eA: La modalità intera fornisce prestazioni di scansione più rapide (fino a 10 ms), mentre la conversione della temperatura in virgola mobile IEEE aumenta il tempo di scansione fino a 50 ms a causa del calcolo aggiuntivo di scala.\u003c\/p\u003e\n\u003chr\u003e\u003chr\u003e\n\u003ch3\u003eLinee guida per l'installazione in campo\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eInstallare il modulo in uno slot compatibile del telaio 1756 ControlLogix con alimentazione di sistema rimossa o seguendo una procedura di hot-swap approvata\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUtilizzare i blocchi terminali RTB specificati (1756-TBNH o 1756-TBSH) con completo inserimento prima di alimentare i circuiti di campo\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMantenere l'integrità del cablaggio della termocoppia utilizzando cavi di compensazione schermati abbinati al tipo di sensore\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEvitare di instradare i cavi della termocoppia vicino a conduttori ad alta tensione o linee di alimentazione commutate\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAssicurarsi del corretto posizionamento della compensazione della giunzione fredda e dell'assenza di gradienti di temperatura indotti dal flusso d'aria al blocco terminale\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerificare la configurazione del tipo di termocoppia prima dell'attivazione del loop per prevenire errori di scala\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43602855624794,"sku":"1756-IT61","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/1756-IT612.jpg?v=1783320124","url":"https:\/\/www.plcmasters.com\/it\/products\/allen-bradley-1756-it6i-controllogix-thermocouple-input-module","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}