{"product_id":"allen-bradley-1794-ib16xt-flex-i-o-digital-input-module","title":"Modulo di ingresso digitale Allen-Bradley 1794-IB16XT FLEX I\/O","description":"\u003ch2\u003eModulo di Ingresso Digitale Allen-Bradley 1794-IB16XT FLEX I\/O\u003c\/h2\u003e\n\u003cp\u003eIl \u003cstrong\u003eAllen-Bradley 1794-IB16XT\u003c\/strong\u003e, anche catalogato come \u003cstrong\u003e1794-IB16XT\u003c\/strong\u003e Modulo di Ingresso Digitale, funziona come componente hardware dedicato per l'acquisizione di segnali discreti a 24 VDC all'interno delle piattaforme di sistema FLEX I\/O. Fornisce 16 canali di ingresso con capacità sinking\/sourcing e funzionamento a temperatura estesa per installazioni di controllo industriale.\u003c\/p\u003e\n\u003ch3\u003eSpecifiche Hardware\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParametro\u003c\/th\u003e\n\u003cth\u003eSpecifiche\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModello\u003c\/td\u003e\n\u003ctd\u003e1794-IB16XT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarca\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinea di Prodotto\u003c\/td\u003e\n\u003ctd\u003eFLEX I\/O Temperatura Estesa (XT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTipo di Modulo\u003c\/td\u003e\n\u003ctd\u003eModulo di Ingresso Digitale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTipo di Ingresso\u003c\/td\u003e\n\u003ctd\u003eDigitale Sinking \/ Sourcing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumero di Ingressi\u003c\/td\u003e\n\u003ctd\u003e16 punti, 1 gruppo da 16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTensione Nominale di Ingresso\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntervallo di Tensione di Funzionamento\u003c\/td\u003e\n\u003ctd\u003e10,0 VDC a 31,2 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTensione in Stato On\u003c\/td\u003e\n\u003ctd\u003e10,0 VDC a 31,2 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTensione in Stato Off\u003c\/td\u003e\n\u003ctd\u003eMassimo 5,0 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorrente in Stato On\u003c\/td\u003e\n\u003ctd\u003eMinimo 2,0 mA a 10 VDC, tipico 4,1 mA a 24 VDC, massimo 8,0 mA a 31,2 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorrente in Stato Off\u003c\/td\u003e\n\u003ctd\u003eMassimo 1,5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorrente FlexBus\u003c\/td\u003e\n\u003ctd\u003e30 mA a 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConsumo Energetico\u003c\/td\u003e\n\u003ctd\u003eMassimo 6,1 W a 31,2 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDispersione Termica\u003c\/td\u003e\n\u003ctd\u003eMassimo 20,8 BTU\/ora a 31,2 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTensione di Isolamento\u003c\/td\u003e\n\u003ctd\u003e50 V continuo, Tipo di Isolamento Base\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperatura di Funzionamento\u003c\/td\u003e\n\u003ctd\u003e-20 °C a +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperatura di Stoccaggio\u003c\/td\u003e\n\u003ctd\u003e-40 °C a +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUmidità Relativa\u003c\/td\u003e\n\u003ctd\u003e5% a 95% senza condensa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibrazione di Funzionamento\u003c\/td\u003e\n\u003ctd\u003e5 g da 10 a 500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUrto di Funzionamento\u003c\/td\u003e\n\u003ctd\u003e30 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndicatori di Stato\u003c\/td\u003e\n\u003ctd\u003e16 LED gialli per stato ingresso\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTipo di Montaggio\u003c\/td\u003e\n\u003ctd\u003eStile aperto, montaggio DIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrado di Protezione\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeso\u003c\/td\u003e\n\u003ctd\u003e0,18 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensioni\u003c\/td\u003e\n\u003ctd\u003eNon specificate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIntegrazione EtherNet\/IP e Backplane FLEX I\/O\u003c\/h3\u003e\n\u003cp\u003eIl 1794-IB16XT si interfaccia con l'architettura FLEX I\/O tramite la connessione FlexBus per la comunicazione distribuita I\/O. Il modulo fornisce 16 punti di ingresso discreti con indicazione dello stato del canale tramite diagnostica LED individuale. La configurazione e lo scambio dati dipendono dall'adattatore FLEX I\/O e dalla piattaforma controller collegati. Il design XT supporta il funzionamento su un intervallo di temperatura esteso senza modificare il fattore di forma standard del modulo FLEX I\/O.\u003c\/p\u003e\n\u003ch3\u003eDomande Frequenti\u003c\/h3\u003e\n\u003cp\u003eD: Quali tipi di segnali di ingresso supporta il modulo 1794-IB16XT?\u003cbr\u003eR: Il modulo supporta segnali di ingresso digitali a 24 VDC con funzionamento sinking e sourcing su 16 punti di ingresso.\u003c\/p\u003e\n\u003cp\u003eD: Qual è il requisito di corrente FlexBus del modulo?\u003cbr\u003eR: Il modulo richiede 30 mA a 5 VDC dall'alimentazione FlexBus.\u003c\/p\u003e\n\u003cp\u003eD: Il modulo fornisce diagnostica individuale per ogni ingresso?\u003cbr\u003eR: Sì. Il modulo include 16 LED di stato gialli, con un indicatore assegnato a ciascun punto di ingresso.\u003c\/p\u003e\n\u003ch3\u003eLinee Guida per l'Installazione in Campo\u003c\/h3\u003e\n\u003cp\u003eInstallare il modulo su un sistema di montaggio DIN con l'adattatore FLEX I\/O e l'assemblaggio della base terminale richiesti. Mantenere la separazione tra il cablaggio degli ingressi discreti e i conduttori ad alta tensione o ad alto rumore per ridurre le interferenze del segnale. Collegare le schermature dei cavi secondo il progetto di messa a terra del quadro di controllo ed evitare la creazione di loop di terra indesiderati.\u003c\/p\u003e\n\u003cp\u003eVerificare che i dispositivi di campo forniscano livelli di tensione entro l'intervallo operativo specificato prima della connessione. Confermare la polarità del cablaggio dei terminali per le configurazioni di ingresso sinking o sourcing. L'installazione deve considerare la ventilazione dell'involucro, la protezione ambientale e l'accessibilità per l'indicazione dello stato del modulo e l'ispezione di manutenzione.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43768284414042,"sku":"1794-IB16XT","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/1794-IB16XT2.jpg?v=1785483064","url":"https:\/\/www.plcmasters.com\/it\/products\/allen-bradley-1794-ib16xt-flex-i-o-digital-input-module","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}