{"product_id":"allen-bradley-193-dnct-devicenet-configuration-terminal","title":"Terminale di configurazione DeviceNet Allen-Bradley 193-DNCT","description":"\u003ch3\u003e\u003cstrong\u003ePanoramica\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eIl terminale portatile di configurazione \u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e193-DNCT\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edi \u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003eRockwell Automation\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eAllen-Bradley è progettato per la messa in servizio, la diagnostica e la gestione dei parametri sulle reti di comunicazione DeviceNet. Sviluppato principalmente per i relè elettronici di sovraccarico Bulletin 193 e i controller motore distribuiti ArmorStart, il terminale consente l'accesso diretto a livello di campo ai nodi DeviceNet senza necessità di software di configurazione basato su PC.\u003c\/p\u003e\n\u003cp\u003eIl design portatile e l'interfaccia guidata da menu permettono al personale di manutenzione e agli ingegneri di messa in servizio di configurare rapidamente i dispositivi di rete, verificare lo stato della comunicazione, monitorare l'attività I\/O e risolvere problemi delle installazioni DeviceNet direttamente dal pannello di controllo o dal quadro di campo.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCaratteristiche principali\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eTerminale portatile per configurazione rete DeviceNet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRiconoscimento automatico della velocità di trasmissione della rete\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndirizzamento automatico dei nodi DeviceNet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInterfaccia di configurazione parametri guidata da menu\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFunzione di scansione rete DeviceNet e scoperta nodi\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCapacità di monitoraggio I\/O in tempo reale\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMonitoraggio diagnostico e statistico della rete\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFunzionalità diretta di lettura\/scrittura parametri\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompatibile con diversi prodotti Allen-Bradley DeviceNet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInclude cavo di comunicazione DeviceNet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifiche tecniche\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecifiche\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDettagli\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumero Modello\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e193-DNCT\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarca\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduttore\u003c\/td\u003e\n\u003ctd\u003eRockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTipo di Prodotto\u003c\/td\u003e\n\u003ctd\u003eTerminale di configurazione DeviceNet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRete di comunicazione\u003c\/td\u003e\n\u003ctd\u003eDeviceNet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConformità protocollo\u003c\/td\u003e\n\u003ctd\u003eConforme a ODVA DeviceNet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMetodo di configurazione\u003c\/td\u003e\n\u003ctd\u003eInterfaccia portatile guidata da menu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRilevamento automatico baud rate\u003c\/td\u003e\n\u003ctd\u003eSupportato\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssegnazione automatica indirizzi\u003c\/td\u003e\n\u003ctd\u003eSupportato\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModifica parametri\u003c\/td\u003e\n\u003ctd\u003eSupporto lettura\/scrittura\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunzione di scansione della rete\u003c\/td\u003e\n\u003ctd\u003eSupportato\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoraggio I\/O\u003c\/td\u003e\n\u003ctd\u003eSupportato\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoraggio statistiche di rete\u003c\/td\u003e\n\u003ctd\u003eSupportato\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterfaccia di Connessione\u003c\/td\u003e\n\u003ctd\u003ePorta di comunicazione DeviceNet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCavo incluso\u003c\/td\u003e\n\u003ctd\u003eCavo DeviceNet 193-CB1 da 1 metro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessori Opzionali\u003c\/td\u003e\n\u003ctd\u003eCavo 193-CM1, Kit Cornice 193-DNCT-BZ1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDispositivi supportati\u003c\/td\u003e\n\u003ctd\u003eBulletin 193-EC, 592-EC, Controller ArmorStart\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNorme EMC\u003c\/td\u003e\n\u003ctd\u003eEN61000-6-4:2001, EN61000-6-2:2005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConformità normativa\u003c\/td\u003e\n\u003ctd\u003eMarcatura CE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStato del ciclo di vita\u003c\/td\u003e\n\u003ctd\u003eFine vita programmata 1 dicembre 2027\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeso\u003c\/td\u003e\n\u003ctd\u003e0,05 libbre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eFamiglie di dispositivi supportate\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eIl\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e193-DNCT\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eè compatibile con diversi prodotti Allen-Bradley per il controllo motore e la protezione da sovraccarico abilitati DeviceNet, inclusi:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRelè elettronici di sovraccarico Bulletin 193-EC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRelè di sovraccarico Bulletin 592-EC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eControllori motore distribuiti ArmorStart\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSistemi di avviatori motore abilitati DeviceNet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFunzioni operative\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eIl terminale rileva automaticamente le impostazioni della velocità di trasmissione della rete e può assegnare un indirizzo nodo disponibile durante la connessione iniziale. La funzione integrata di scansione “Who” identifica i nodi attivi sul segmento DeviceNet, semplificando le attività di messa in servizio e manutenzione.\u003c\/p\u003e\n\u003cp\u003eI tecnici possono navigare direttamente ai numeri di parametro per una modifica più rapida, monitorare i messaggi I\/O in tempo reale e ispezionare la diagnostica della comunicazione senza scollegare i dispositivi di campo dalla rete.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eApplicazioni tipiche\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eGli usi industriali comuni includono:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMessa in servizio della rete DeviceNet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfigurazione dell'avviatore motore\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRegolazione dei parametri del relè di sovraccarico\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDiagnostica e risoluzione problemi a livello di campo\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSostituzione e configurazione dei dispositivi\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerifica della manutenzione durante le fermate\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStrumento portatile di servizio per sistemi DeviceNet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eDomande frequenti\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003eQual è lo scopo principale del 193-DNCT?\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eIl\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e193-DNCT\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eviene utilizzato per configurare, monitorare e risolvere problemi dei dispositivi compatibili DeviceNet direttamente sul campo senza necessità di un computer.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eIl terminale supporta la configurazione automatica della rete?\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eSì. L'unità supporta sia il rilevamento automatico della velocità di trasmissione che l'assegnazione automatica dell'indirizzo nodo.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eQuale cavo di comunicazione è incluso?\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eIl terminale include il cavo di comunicazione DeviceNet 193-CB1 lungo un metro.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eIl terminale può monitorare l'attività di rete in tempo reale?\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eSì. Supporta il monitoraggio I\/O, la visualizzazione delle statistiche di rete e l'ispezione diagnostica DeviceNet.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43392198606938,"sku":"193-DNCT","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/193-DNCT2.jpg?v=1779162202","url":"https:\/\/www.plcmasters.com\/it\/products\/allen-bradley-193-dnct-devicenet-configuration-terminal","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}