{"product_id":"emerson-kl3106x1-ba1-i-s-thermocouple-input-charm","title":"Emerson KL3106X1-BA1 | I.S. Thermocouple Input CHARM","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eKL3106X1-BA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an intrinsically safe (I.S.) analog input CHARM module from Emerson, specifically designed for thermocouple signal acquisition in DeltaV systems. It allows precise and reliable temperature measurement in hazardous areas while maintaining compliance with global safety standards.\u003c\/p\u003e\n\u003cp\u003eThis compact CHARM module integrates directly into DeltaV racks, providing single-channel thermocouple input with low CHARM bus power consumption. The terminal block key position BA1 ensures correct wiring and installation, while the rugged design withstands vibration, shock, and airborne contaminants. No calibration is required, and the module has no user-serviceable parts, making it maintenance-free.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eModel:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eKL3106X1-BA1\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eModule Type: Intrinsically Safe Analog Input (AI) CHARM\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSignal Type: Thermocouple input (supports multiple types)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafety Type: Intrinsically Safe (I.S.)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCHARM Bus Power: +6.3 VDC at minimal current\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eField Circuit Power: +24 VDC, ~23 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eChannels: Single-channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTerminal Block Key Position: BA1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: –40 °C to +70 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHumidity: 5–95% RH, non-condensing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShock Resistance: 10 g, half-sine wave, 11 ms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVibration: 2–13.2 Hz: 1 mm peak-to-peak; 13.2–150 Hz: 0.7 g\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAirborne Contaminants: ISA-S71.04-1985 Class G3\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSafety \u0026amp; Compliance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eHazardous Atmosphere Ratings:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eII 3(1) G Ex ec [ia Ga] IIC Gc\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eII 3G (1D) Ex ec [ia IIIC Da] IIC Gc\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eClass I, Division 2, Groups A–D\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eZone 2 AEx ec [ia Ga\/IIIC Da] IIC Gc\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eCertifications: ATEX, IECEx, FM, UKEX\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInstallation Note: Do not insert or remove while energized unless area is confirmed non-hazardous\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Highlights\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSingle-channel thermocouple input for accurate temperature measurement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntrinsically safe design suitable for hazardous environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompact CHARM form factor for seamless DeltaV system integration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWide environmental tolerance: –40 °C to +70 °C, Class G3 airborne contaminants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eKeyed terminal block BA1 ensures proper connection and installation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eHazardous area temperature monitoring using thermocouples\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDeltaV systems requiring single-channel intrinsically safe analog input\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProcess plants in oil, gas, chemical, or other Zone 2 \/ Class I Div. 2 environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which thermocouple types are supported by KL3106X1-BA1?\u003c\/strong\u003e\u003cbr\u003eA: The module supports standard thermocouple types (J, K, T, E, R, S, B, N) depending on configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can it be used in Class I Division 2 areas?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it is certified for Zone 2 \/ Class I Div. 2 hazardous areas.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is calibration required for operation?\u003c\/strong\u003e\u003cbr\u003eA: No, the module is factory-calibrated and requires no user maintenance.\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":43064960581722,"sku":"KL3106X1-BA1","price":178.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/KL3106X1-BA12.jpg?v=1773805390","url":"https:\/\/www.plcmasters.com\/it\/products\/emerson-kl3106x1-ba1-i-s-thermocouple-input-charm","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}