Descrizione
Product Description
The KL3106X1-LS1 from Emerson is a single-channel analog input CHARM module engineered for thermocouple signals in DeltaV systems. Its intrinsically safe (I.S.) design ensures secure operation in hazardous environments, including Zone 2 and Class I Division 2 locations.
Featuring LS1 keyed terminals, this module prevents miswiring and simplifies installation. The compact CHARM format allows seamless integration into DeltaV racks while maintaining a minimal CHARM bus power draw. With broad environmental tolerance and robust resistance to shock, vibration, and airborne contaminants, it provides reliable temperature measurement in industrial conditions.
Technical Specifications
-
Model: KL3106X1-LS1
-
Module Type: Intrinsically Safe (I.S.) Analog Input CHARM
-
Signal Type: Thermocouple input (supports multiple types)
-
Safety Type: Intrinsically Safe (I.S.)
-
CHARM Bus Power: +6.3 VDC at minimal consumption
-
Field Circuit Power: +24 VDC, ~60 mA
-
Channels: Single-channel CHARM
-
Terminal Block Key Position: LS1
-
Operating Temperature: –40 °C to +70 °C
-
Humidity: 5–95% RH, non-condensing
-
Shock Resistance: 10 g, half-sine wave, 11 ms
-
Vibration: 2–13.2 Hz: 1 mm peak-to-peak; 13.2–150 Hz: 0.7 g
-
Airborne Contaminants: ISA-S71.04-1985 Class G3
-
Maintenance: No calibration required; no user-serviceable parts
Safety & Compliance
-
Hazardous Atmosphere Ratings:
-
II 3(1) G Ex ec [ia Ga] IIC Gc
-
II 3G (1D) Ex ec [ia IIIC Da] IIC Gc
-
Class I, Division 2, Groups A–D
-
Zone 2 AEx ec [ia Ga] IIC Gc
-
Certifications: ATEX, IECEx, FM, UKEX
-
Installation Note: Do not insert or remove while energized unless area is verified non-hazardous
Key Highlights
-
Single-channel thermocouple input for accurate temperature monitoring
-
Intrinsically safe design for hazardous area applications
-
LS1 keyed terminal block ensures proper wiring and safe installation
-
Broad environmental tolerance: –40 °C to +70 °C; resistant to shock, vibration, and Class G3 airborne contaminants
-
Compact CHARM module for seamless DeltaV system integration
Applications
-
Temperature measurement in hazardous areas using thermocouples
-
Integration into DeltaV I/O systems for process control
-
Suitable for oil, gas, chemical, and other Zone 2 / Class I Div. 2 industrial environments
FAQ
Q: Which thermocouple types are compatible with KL3106X1-LS1?
A: Supports standard thermocouples including types J, K, T, E, R, S, B, and N depending on configuration.
Q: Can this module be installed in Zone 2 locations?
A: Yes, it is certified for Zone 2 and Class I Division 2 hazardous areas.
Q: Is calibration required before operation?
A: No, the module is factory-calibrated and maintenance-free.
Caratteristiche
Accogliamo ordini all'ingrosso e abbiamo una quantità minima d'ordine di una sola unità.
Su richiesta, possiamo fornire tutta la documentazione necessaria, inclusi i Certificati di Origine/Conformità e altri documenti di esportazione richiesti.
Per gli articoli in magazzino, puntiamo a consegnare entro 1-3 giorni dalla conferma del pagamento. Gli articoli con tempi di consegna specificati saranno consegnati secondo il programma indicato.
Accettiamo il pagamento 100% T/T (Trasferimento Telegrafico) prima della spedizione. Per gli articoli con tempi di consegna, è richiesto un deposito del 30% anticipato, con il restante 70% da pagare prima della spedizione. Per i trasferimenti in RMB, si prega di contattarci se avete un agente in Cina.
Offriamo una garanzia standard di un anno su tutti gli articoli nuovi e originali. Se desideri una garanzia estesa, contattaci per i dettagli sui costi aggiuntivi.
La tua soddisfazione è importante per noi. Se devi restituire un articolo, deve essere fatto entro 30 giorni dalla data dell'ordine. Il prodotto deve essere inutilizzato, non aperto e nella sua confezione originale con tutti gli accessori inclusi. I rimborsi vengono elaborati entro 5-7 giorni lavorativi dopo aver ricevuto l'articolo restituito. Si prega di notare che le spese di spedizione e i costi correlati non sono rimborsabili.