{"product_id":"foxboro-p0930at-pressure-transmitter-fieldbus-module","title":"Foxboro P0930AT Pressure Transmitter Fieldbus Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFoxboro P0930AT\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a multifunctional industrial device that appears in different configurations depending on system requirements. It is most commonly implemented as a pneumatic\/electronic pressure transmitter for continuous process measurement, while certain system integrations classify it as a communication or interface module within the Foxboro I\/A Series architecture.\u003c\/p\u003e\n\u003cp\u003eIn transmitter configurations, the unit delivers stable pressure measurement across a broad operating range with consistent accuracy. In control system deployments, it may function as a fieldbus interface or termination module, enabling communication between distributed control components and field networks.\u003c\/p\u003e\n\u003cp\u003eIts mechanical robustness, material flexibility, and environmental protection make it suitable for deployment in demanding process industries.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral Information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eModel:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eP0930AT\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eManufacturer: Foxboro\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduct Category: Pressure Transmitter \/ Fieldbus Interface \/ Termination Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSystem Compatibility: Foxboro I\/A Series (for communication variants)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePressure Measurement Version\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMeasurement Range: Configurable from low differential ranges (inches of water) up to 10,000 psi\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAccuracy: ±0.25% of calibrated span\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOutput Signal: 4–20 mA DC (industry standard loop-powered)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResponse: Stable measurement suitable for continuous process control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower Supply: 24 VDC typical\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical \u0026amp; Materials\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eEnclosure Rating: NEMA 4 \/ IP66 (dust-tight and water-resistant)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWetted Materials Options:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e316L stainless steel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHastelloy C (corrosion-resistant applications)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMonel (marine or aggressive environments)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eElectrical Interface: M12 connector or terminal block wiring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHousing: Heavy-duty industrial enclosure for field installation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Conditions (Transmitter)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: –40°C to +121°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHumidity: Up to 95% RH, non-condensing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSuitable for outdoor and hazardous industrial locations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFieldbus Interface Variant\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCommunication Standard: FOUNDATION Fieldbus H1 (IEC 61158)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFieldbus Ports: Dual redundant channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTransmission Rate: 31.25 kbps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSegment Power Supply: Up to 300 mA output\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIsolation: 1500 Vrms between ports and system backplane\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower Consumption: Approximately 4–5 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: –20°C to +70°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTermination \/ Communication Module Variant\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eFunction: Signal termination and protocol interface\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupported Protocols: Modbus, PROFIBUS, DeviceNet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMounting: DIN rail or panel installation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDimensions: Compact form factor for cabinet integration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: –40°C to +70°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eConfigurable as pressure transmitter or communication interface module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMeasurement accuracy maintained within ±0.25% of span\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWide pressure coverage from low differential to high-pressure applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial-grade enclosure rated for harsh environmental exposure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOptional redundant fieldbus communication for high system availability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eElectrical isolation and diagnostics for reliable network operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMultiple material selections for corrosion resistance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProcess pressure monitoring in oil and gas production\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eChemical and petrochemical plant instrumentation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHydraulic and fluid control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDistributed control system (DCS) communication networks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnvironmental and utility monitoring systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the P0930AT strictly a pressure transmitter?\u003c\/strong\u003e\u003cbr\u003eA: Not always. While widely used as a pressure transmitter, some system configurations define it as a fieldbus or communication module within Foxboro I\/A Series systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What communication options are available?\u003c\/strong\u003e\u003cbr\u003eA: Depending on the version, it may support FOUNDATION Fieldbus, Modbus, PROFIBUS, or DeviceNet protocols.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can it operate in harsh environments?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the enclosure rating (NEMA 4 \/ IP66) and material options allow installation in corrosive, wet, or high-temperature environments.\u003c\/p\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":43190962946138,"sku":"P0930AT","price":177.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/P0400YGFBM061_d675d208-4242-4410-8766-e6b6f0eb8042.jpg?v=1775631602","url":"https:\/\/www.plcmasters.com\/it\/products\/foxboro-p0930at-pressure-transmitter-fieldbus-module","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}