Descrizione
Overview
The IC670ALG620 module from GE Fanuc is a high-precision RTD input interface designed for Field Control systems. It supports four independent channels and is compatible with both 3-wire and 4-wire RTD sensors, including Platinum, Nickel, Nickel/Iron, and Copper types. The module converts resistance measurements into accurate temperature data for process monitoring, control applications, and industrial automation systems.
Key Features
-
Four fully isolated RTD input channels for flexible sensor integration
-
Supports 3-wire and 4-wire RTD configurations
-
Configurable measurement ranges: 0–500 Ω or 0–3000 Ω
-
Outputs in resistance (Ω), Celsius (°C), or Fahrenheit (°F) with tenths resolution
-
Built-in diagnostics for open-wire, short-circuit, overrange/underrange, and high/low alarms
-
No external loop power required, reducing installation complexity
-
Industrial-grade reliability for continuous operation
Technical Specifications
| Specification | Details |
|---|---|
| Model Number | IC670ALG620 |
| Input Channels | 4 independent RTD inputs (3-wire or 4-wire) |
| Supported RTD Types | Platinum, Nickel, Nickel/Iron, Copper |
| Resistance Ranges | 0–500 Ω, 0–3000 Ω (selectable) |
| Measurement Units | Ω, °C, °F (tenths resolution) |
| Scan Time | 210 ms (60 Hz), 230 ms (50 Hz) |
| Digital Resolution | 15-bit plus sign |
| Maximum Lead Resistance | 5 Ω per lead |
| Normal Mode Rejection | 60 dB at 50/60 Hz, 100% span |
| Temperature Sensitivity | ±0.004% of reading, ±1.5 mV/°C referred to input (0–60°C) |
| Fault Detection | Open RTD, short, underrange, overrange, high/low alarms |
| Power Requirements | Draws up to 190 mA from BIU supply, no loop power needed |
| Dimensions | 120 × 50 × 100 mm |
| Weight | 0.45 kg |
Applications
Ideal for process control systems, distributed control stations, and temperature monitoring in industrial environments where precise RTD measurements are required. It integrates seamlessly with GE Field Control systems for automated and reliable operation.
FAQ
Q: Can the module measure multiple RTD types simultaneously?
A: Yes, each channel can be individually configured for Platinum, Nickel, Nickel/Iron, or Copper RTDs.
Q: Is external power required for the RTDs?
A: No, the module does not require loop power; it draws power directly from the Bus Interface Unit.
Q: How is configuration performed?
A: The module is configured via a handheld device connected to the main Bus Interface Unit.
Caratteristiche
Accogliamo ordini all'ingrosso e abbiamo una quantità minima d'ordine di una sola unità.
Su richiesta, possiamo fornire tutta la documentazione necessaria, inclusi i Certificati di Origine/Conformità e altri documenti di esportazione richiesti.
Per gli articoli in magazzino, puntiamo a consegnare entro 1-3 giorni dalla conferma del pagamento. Gli articoli con tempi di consegna specificati saranno consegnati secondo il programma indicato.
Accettiamo il pagamento 100% T/T (Trasferimento Telegrafico) prima della spedizione. Per gli articoli con tempi di consegna, è richiesto un deposito del 30% anticipato, con il restante 70% da pagare prima della spedizione. Per i trasferimenti in RMB, si prega di contattarci se avete un agente in Cina.
Offriamo una garanzia standard di un anno su tutti gli articoli nuovi e originali. Se desideri una garanzia estesa, contattaci per i dettagli sui costi aggiuntivi.
La tua soddisfazione è importante per noi. Se devi restituire un articolo, deve essere fatto entro 30 giorni dalla data dell'ordine. Il prodotto deve essere inutilizzato, non aperto e nella sua confezione originale con tutti gli accessori inclusi. I rimborsi vengono elaborati entro 5-7 giorni lavorativi dopo aver ricevuto l'articolo restituito. Si prega di notare che le spese di spedizione e i costi correlati non sono rimborsabili.