{"product_id":"abb-tu840-3bse020846r1-module-termination-unit","title":"ABB TU840 3BSE020846R1 Module Termination Unit","description":"\u003ch3\u003e\u003cstrong\u003eGeneral Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle Number\u003c\/strong\u003e: \u003cstrong\u003e3BSE020846R1\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Protocol\u003c\/strong\u003e: Modulebus\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaster or Slave\u003c\/strong\u003e: N\/A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine Redundancy\u003c\/strong\u003e: Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Redundancy\u003c\/strong\u003e: Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot Swap\u003c\/strong\u003e: No\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType\u003c\/strong\u003e: Redundant TB840\/TB840A, Redundant I\/O, Single Power\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input\u003c\/strong\u003e: 24 V d.c (19.2 - 30 V)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting\u003c\/strong\u003e: Vertical or Horizontal\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Data\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector\u003c\/strong\u003e: N\/A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e24 V Consumption\u003c\/strong\u003e: N\/A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModuleBus Current Distribution\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003eMaximum: 5 V 1.5 A\u003c\/li\u003e\n\u003cli\u003e24 V: 1.5 A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Keys\u003c\/strong\u003e: 36 different combinations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAcceptable Wire Sizes\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003eSolid: 0.2 - 2.5 mm²\u003c\/li\u003e\n\u003cli\u003eStranded: 0.2 - 2.5 mm², 24 - 12 AWG\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended Torque\u003c\/strong\u003e: 0.5 Nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Insulation Voltage\u003c\/strong\u003e: 50 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDielectric Test Voltage\u003c\/strong\u003e: 500 V a.c\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e: 2.0 W\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironment and Certification\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE Marking\u003c\/strong\u003e: Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Safety\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003eEN 61010-1, UL 61010-1\u003c\/li\u003e\n\u003cli\u003eEN 61010-2-201, UL 61010-2-201\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Location\u003c\/strong\u003e: cULus Hazardous Location Class 1 Zone 2, ATEX Zone 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine Certificates\u003c\/strong\u003e: ABS, BV, DNV-GL, LR\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature, Operating\u003c\/strong\u003e: 0 to +55 °C (+32 to +131 °F), approvals are issued for +5 to +55 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature, Storage\u003c\/strong\u003e: -40 to +70 °C (-40 to +158 °F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e: 5 to 95 %, non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Ambient Temperature\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e55 °C (131 °F) for vertical mounting\u003c\/li\u003e\n\u003cli\u003e40 °C (104 °F) for horizontal mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquipment Class\u003c\/strong\u003e: Class I according to IEC 60536 (earth protected)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIngress Protection\u003c\/strong\u003e: IP20 according to IEC 60529\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance\u003c\/strong\u003e: DIRECTIVE\/2011\/65\/EU (EN 50581:2012)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE Compliance\u003c\/strong\u003e: DIRECTIVE\/2012\/19\/EU\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth\u003c\/strong\u003e: 124 mm (4.88 in.)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight\u003c\/strong\u003e: 186 mm (7.32 in.) including latch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth\u003c\/strong\u003e: 47 mm (1.85 in.)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e: 0.45 kg (0.99 lbs.)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":41506561261658,"sku":"TU840","price":198.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/ABBTU8403BSE020846R12.jpg?v=1740999253","url":"https:\/\/www.plcmasters.com\/lt\/products\/abb-tu840-3bse020846r1-module-termination-unit","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}