Aprašymas
Product Description
The KL3103X1-BA1 is an intrinsically safe (I.S.) digital input CHARM module from Emerson, designed for DeltaV systems. It supports 24 VDC dry contact signals, allowing direct connection of field devices such as switches, pushbuttons, and contact closures. This module ensures safe and reliable monitoring in hazardous locations, integrating seamlessly into the DeltaV CHARM architecture.
Engineered for Zone 2 / Class I Division 2 environments, the KL3103X1-BA1 combines intrinsic safety with robust environmental tolerance, including resistance to vibration, shock, and airborne contaminants. Its compact form factor and low-power CHARM bus interface facilitate easy installation and modular expansion.
Core Technical Specifications
-
Model: KL3103X1-BA1
-
Module Type: Intrinsically Safe Digital Input (DI) CHARM
-
Signal Type: 24 VDC dry contact
-
Safety Classification: Intrinsically Safe (I.S.)
-
CHARM Bus Power: +6.3 VDC, 32 mA
-
Field Circuit Power: +24 VDC, ~10 mA
-
Channels: Single-channel input
-
Terminal Block Key: 2C
-
Operating Temperature: –40 °C to +70 °C
-
Relative Humidity: 5–95% RH, non-condensing
-
Shock Resistance: 10 g, half-sine wave, 11 ms
-
Vibration: 2–13.2 Hz: 1 mm peak-to-peak; 13.2–150 Hz: 0.7 g
-
Airborne Contaminants Rating: ISA-S71.04 Class G3
-
Weight: 0.18 lbs
Safety & Compliance
-
Hazardous Area Ratings:
-
II 3G Ex nA [nL] IIC Gc
-
II 3G Ex ec [ic] IIC Gc
-
Class I, Division 2, Groups A–D
-
Zone 2 AEx/Ex ec [ic] IIC Gc
-
Certifications: ATEX, IECEx, FM, UKEX
-
Installation Note: Module must not be inserted or removed while energized unless the area is confirmed safe
Functional Advantages
-
Intrinsically safe design suitable for hazardous areas
-
Supports 24 VDC dry contact inputs for direct field device monitoring
-
Compact CHARM format allows easy integration and modular expansion
-
Robust diagnostics ensure reliable operation of connected field devices
-
Wide environmental tolerance for harsh industrial conditions
Applications
-
Monitoring switches and pushbuttons in oil and gas facilities
-
Remote hazardous area I/O panels
-
Chemical and petrochemical process control systems
-
DeltaV system integration for single-channel dry contact inputs
FAQ
Q: Is this module suitable for hazardous Zone 2 locations?
A: Yes, the KL3103X1-BA1 is certified intrinsically safe for Zone 2 / Class I Div. 2 hazardous areas.
Q: Can it monitor multiple devices?
A: This module provides a single-channel input; multiple modules can be installed for multi-device monitoring.
Q: Does it require calibration?
A: No calibration is required, and the module has no user-serviceable parts.
Savybės
Mes priimame didelius užsakymus ir turime minimalią užsakymo kiekį – tik vieną vienetą.
Pagal užklausą galime pateikti visus reikiamus dokumentus, įskaitant kilmės/atitikties sertifikatus ir kitus būtinus eksporto dokumentus.
Sandėlyje esančius daiktus siekiame pristatyti per 1-3 dienas po apmokėjimo patvirtinimo. Daiktai su nurodytu pristatymo terminu bus pristatyti pagal nurodytą grafiką.
Mes priimame 100 % T/T (telegrafinius pervedimus) apmokėjimą prieš išsiuntimą. Prekėms su laukimo terminais reikalinga 30 % avansinė įmoka, likusieji 70 % turi būti sumokėti prieš išsiuntimą. Dėl RMB pervedimų, jei turite agentą Kinijoje, susisiekite su mumis.
Mes siūlome standartinę vienerių metų garantiją visiems naujiems ir originaliems daiktams. Jei jums reikalinga pratęsta garantija, prašome susisiekti su mumis dėl papildomų kainos detalių.
Jūsų pasitenkinimas mums svarbus. Jei reikia grąžinti prekę, tai turi būti padaryta per 30 dienų nuo užsakymo datos. Produktas turi būti nenaudotas, neuždarytas ir originalioje pakuotėje su visais priedais. Pinigų grąžinimas atliekamas per 5-7 darbo dienas nuo grąžintos prekės gavimo. Atkreipkite dėmesį, kad siuntimo ir susijusios išlaidos negrąžinamos.