{"product_id":"emerson-se4307t01-analog-input-charm-module","title":"Emerson SE4307T01 Analog Input CHARM Module","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEmerson SE4307T01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an Intrinsically Safe (IS) Analog Input CHARM designed for the DeltaV™ Electronic Marshalling system. It supports both 4–20 mA and optional 0–20 mA signals. Additionally, it enables HART communication for enhanced device diagnostics. The module works with both 2-wire and 4-wire transmitters. Moreover, it eliminates traditional marshalling cabinets, streamlines wiring, and supports faster commissioning. Its rugged design and certification allow safe use in hazardous areas, including\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eClass I Division 2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIEC Zone II\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003eSignal and Input\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Type\u003c\/strong\u003e: 4–20 mA (optional 0–20 mA), with or without HART\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSupported Devices\u003c\/strong\u003e: 2-wire and 4-wire transmitters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Signal Range\u003c\/strong\u003e: 4–20 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFull Signal Range\u003c\/strong\u003e: 0 to 22 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e: \u0026lt;303 Ω\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003ePower and Accuracy\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eField Power (2-wire devices)\u003c\/strong\u003e: ≥16.0 V at 20 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAccuracy (0–60°C)\u003c\/strong\u003e: ±0.1% of span\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAccuracy (-40 to 70°C)\u003c\/strong\u003e: ±0.25% of span\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRepeatability\u003c\/strong\u003e: ±0.05% of span\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e: 16-bit A\/D converter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eIsolation and Safety\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation Type\u003c\/strong\u003e: Galvanically isolated (EN 60079-11)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePeak Isolation Voltage\u003c\/strong\u003e: 375 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHazardous Area Ratings\u003c\/strong\u003e: Class I Division 2, IEC Zone II certified\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCHARM Power Consumption\u003c\/strong\u003e: Max 60 mA @ 24 VDC ±10%\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHeat Dissipation\u003c\/strong\u003e: 0.86 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eHART Communication\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHART Version\u003c\/strong\u003e: v7\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHART Functions\u003c\/strong\u003e: Pass-through for AMS; device status and variables available\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUpdate Rate\u003c\/strong\u003e: Faster than 1 second (depends on device and load)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eEnvironmental Specifications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: -40°C to +70°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHumidity Range\u003c\/strong\u003e: 5% to 95%, non-condensing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShock Resistance\u003c\/strong\u003e: 10g, ½ sinewave for 11 ms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Rating\u003c\/strong\u003e: ISA-S71.04 Class G3\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":42080428982362,"sku":"SE4307T01","price":269.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/SE4307T01.jpg?v=1752821936","url":"https:\/\/www.plcmasters.com\/lt\/products\/emerson-se4307t01-analog-input-charm-module","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}