Aprašymas
Overview
The EPRO CON021 + PR6423/015-110 system delivers precise non-contact monitoring of shaft displacement and vibration, engineered for high-performance rotating machinery such as turbines, compressors, pumps, and gearboxes. It is designed for predictive maintenance, early fault detection, and compliance with API 670 standards.
This solution combines the PR6423/015-110 Eddy Current Probe with the CON021 Signal Converter to provide accurate, linear outputs suitable for integration into machine protection and monitoring systems.
PR6423/015-110 Sensor Probe
-
Type: Eddy current displacement and vibration sensor
-
Measurement Tip Diameter: 8 mm
-
Linear Range: 2 mm (80 mils)
-
Initial Air Gap: 1.1 mm (43 mils)
-
Sensitivity / Scale Factor (ISF): 8 V/mm ±5% (0–45 °C)
-
Linearity (DSL): ±0.025 mm within 0–45 °C
-
Minimum Shaft Diameter: 25 mm (0.98 in)
-
Operating Temperature: –40 °C to +150 °C (sensor body)
-
Protection Rating: IP66 (IEC 60529)
-
Target Material: Standard ferromagnetic steel (42CrMo4 / AISI 4140)
-
Typical Applications: Shaft vibration, axial displacement, eccentricity, and speed measurement in sleeve-bearing machines
CON021 Converter Module
-
Function: Signal conditioning and conversion for PR6423 probes
-
Frequency Range: 0–20 kHz (–3 dB)
-
Rise Time: <15 μs
-
Supply Voltage: –23 V to –32 V DC
-
Output Voltage Range: –4 V to –20 V
-
Operating Temperature: –30 °C to +100 °C
-
Protection Class: IP20
-
Housing Material: LMgSi alloy
-
Mounting: Panel mount with four M5x20 screws
Applications
-
Power Generation: Steam and gas turbine shaft vibration monitoring
-
Petrochemical: Axial displacement detection in pumps and compressors
-
Industrial Machinery: Gearbox vibration, fan rotor eccentricity, and high-speed rotating shafts
Technical Comparison / FAQ
Q: Can the sensor measure non-ferrous shafts?
A: The PR6423/015-110 is optimized for ferromagnetic steel. Non-ferrous targets may require alternative probe types.
Q: What is the maximum shaft diameter for accurate readings?
A: The system is suitable for shafts ≥25 mm in diameter; larger diameters may require recalibration.
Q: Are the converter outputs compatible with standard PLCs?
A: Yes, the CON021 provides linear voltage outputs that integrate with most machine protection and monitoring systems.
Summary Table
| Component | Key Features | Operating Temp | Output |
|---|---|---|---|
| PR6423/015-110 Sensor | 8 mm eddy current tip, 2 mm range | –40 °C to +150 °C | 8 V/mm sensitivity |
| CON021 Converter | Signal conditioning, fast rise time <15 μs | –30 °C to +100 °C | –4 V to –20 V linear |
Savybės
Mes priimame didelius užsakymus ir turime minimalią užsakymo kiekį – tik vieną vienetą.
Pagal užklausą galime pateikti visus reikiamus dokumentus, įskaitant kilmės/atitikties sertifikatus ir kitus būtinus eksporto dokumentus.
Sandėlyje esančius daiktus siekiame pristatyti per 1-3 dienas po apmokėjimo patvirtinimo. Daiktai su nurodytu pristatymo terminu bus pristatyti pagal nurodytą grafiką.
Mes priimame 100 % T/T (telegrafinius pervedimus) apmokėjimą prieš išsiuntimą. Prekėms su laukimo terminais reikalinga 30 % avansinė įmoka, likusieji 70 % turi būti sumokėti prieš išsiuntimą. Dėl RMB pervedimų, jei turite agentą Kinijoje, susisiekite su mumis.
Mes siūlome standartinę vienerių metų garantiją visiems naujiems ir originaliems daiktams. Jei jums reikalinga pratęsta garantija, prašome susisiekti su mumis dėl papildomų kainos detalių.
Jūsų pasitenkinimas mums svarbus. Jei reikia grąžinti prekę, tai turi būti padaryta per 30 dienų nuo užsakymo datos. Produktas turi būti nenaudotas, neuždarytas ir originalioje pakuotėje su visais priedais. Pinigų grąžinimas atliekamas per 5-7 darbo dienas nuo grąžintos prekės gavimo. Atkreipkite dėmesį, kad siuntimo ir susijusios išlaidos negrąžinamos.