Praleisti turinį
Foxboro P0973CND FCP Termination Module I/A Series

Foxboro P0973CND FCP Termination Module I/A Series

  • 17 Sandėlyje
  • Manufacturer: Foxboro

  • Product No.: P0973CND

  • Condition: Sandėlyje

  • Product Type: FCP Termination Module

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 500g

  • Shipping port: Xiamen

  • Warranty: 12 months

{"id":43198968299610,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"P0973CND","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Foxboro P0973CND FCP Termination Module I\/A Series","public_title":null,"options":["Default Title"],"price":17700,"weight":500,"compare_at_price":35000,"inventory_management":"shopify","barcode":"USA","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}

Aprašymas

Product Description

The Foxboro P0973CND is a field termination assembly engineered to interface field wiring directly with Foxboro Field Control Processors (FCPs) within the I/A Series Distributed Control System. It provides a structured and reliable connection point for routing both analog and discrete signals from field instruments into the control layer.

As a passive termination unit, it does not require independent power for signal handling, which simplifies installation and improves overall system reliability. The module is designed for continuous operation in demanding industrial environments, with robust mechanical construction to withstand vibration, temperature variation, and long-term use.

In some system configurations, the P0973CND is supplied as part of an integrated FCP assembly, which explains references to onboard processing and memory. However, in its standalone role, it functions strictly as a signal termination and distribution interface.

Technical Specifications

General Information

  • Model: P0973CND

  • Functional Type: Field Termination Assembly

  • System Compatibility: Foxboro I/A Series FCP platforms

  • Role: Signal termination and routing interface for field devices

Electrical Characteristics

  • Signal Types Supported: Analog and digital I/O

  • Terminal Count: Typically 32 points

  • Terminal Style: Screw-clamp connections

  • Supported Wire Size: 14–22 AWG

  • Power Requirement: Not required for passive operation

Integrated System Variant (when part of FCP assembly)

  • Processor: Single CPU (dual optional for redundancy)

  • Memory: Approx. 16 MB SDRAM, 32 MB Flash

  • Supply Voltage: 24 VDC (redundant input supported)

  • Power Consumption: Up to 8.5 W (applies to active assemblies only)

Mechanical Details

  • Mounting Options: DIN rail or panel-mounted installation

  • Housing Material: Industrial-grade thermoplastic (polycarbonate typical)

  • Dimensions: Vary by revision, approx.

    • 100 × 50 × 25 mm (compact form)

    • Up to 6 × 18 × 20 cm (assembly variant)

  • Weight: 0.5 kg

Environmental Ratings

  • Operating Temperature:

    • Passive module: –40 °C to +85 °C

    • Processor-integrated assembly: 0 °C to +60 °C

  • Storage Temperature: –55 °C to +90 °C

  • Humidity: Up to 95% RH, non-condensing

  • Resistance: Designed for vibration, dust exposure, and industrial conditions

Key Features

  • Centralized termination point for structured field wiring

  • Passive architecture reduces failure points and simplifies maintenance

  • Supports mixed analog and discrete signal termination

  • Flexible mounting options for cabinet integration

  • Rugged enclosure suitable for harsh process environments

  • Seamless compatibility with Foxboro FCP-based systems

Application Scenarios

  • Field signal termination in Foxboro DCS cabinets

  • Interface layer between sensors/actuators and FCP controllers

  • Process industries including oil & gas, power generation, and chemicals

  • High-vibration installations such as turbines and heavy machinery systems

FAQ

Q: Does the P0973CND require a power supply?
A: No. In its standard form, it is a passive termination module and does not consume power.

Q: Why do some listings mention CPU and memory?
A: Those specifications refer to configurations where the module is integrated into an FCP assembly. The standalone termination unit itself does not include active processing.

Q: What type of wiring does it support?
A: It uses screw terminals compatible with 14–22 AWG wires, suitable for typical industrial field wiring practices.

Savybės

Mes priimame didelius užsakymus ir turime minimalią užsakymo kiekį – tik vieną vienetą.

Pagal užklausą galime pateikti visus reikiamus dokumentus, įskaitant kilmės/atitikties sertifikatus ir kitus būtinus eksporto dokumentus.

Sandėlyje esančius daiktus siekiame pristatyti per 1-3 dienas po apmokėjimo patvirtinimo. Daiktai su nurodytu pristatymo terminu bus pristatyti pagal nurodytą grafiką.

Mes priimame 100 % T/T (telegrafinius pervedimus) apmokėjimą prieš išsiuntimą. Prekėms su laukimo terminais reikalinga 30 % avansinė įmoka, likusieji 70 % turi būti sumokėti prieš išsiuntimą. Dėl RMB pervedimų, jei turite agentą Kinijoje, susisiekite su mumis.

Mes siūlome standartinę vienerių metų garantiją visiems naujiems ir originaliems daiktams. Jei jums reikalinga pratęsta garantija, prašome susisiekti su mumis dėl papildomų kainos detalių.

Jūsų pasitenkinimas mums svarbus. Jei reikia grąžinti prekę, tai turi būti padaryta per 30 dienų nuo užsakymo datos. Produktas turi būti nenaudotas, neuždarytas ir originalioje pakuotėje su visais priedais. Pinigų grąžinimas atliekamas per 5-7 darbo dienas nuo grąžintos prekės gavimo. Atkreipkite dėmesį, kad siuntimo ir susijusios išlaidos negrąžinamos.

Rekomenduojama

Papildomi produktai