Aprašymas
Overview
The IC670ALG620 module from GE Fanuc is a high-precision RTD input interface designed for Field Control systems. It supports four independent channels and is compatible with both 3-wire and 4-wire RTD sensors, including Platinum, Nickel, Nickel/Iron, and Copper types. The module converts resistance measurements into accurate temperature data for process monitoring, control applications, and industrial automation systems.
Key Features
-
Four fully isolated RTD input channels for flexible sensor integration
-
Supports 3-wire and 4-wire RTD configurations
-
Configurable measurement ranges: 0–500 Ω or 0–3000 Ω
-
Outputs in resistance (Ω), Celsius (°C), or Fahrenheit (°F) with tenths resolution
-
Built-in diagnostics for open-wire, short-circuit, overrange/underrange, and high/low alarms
-
No external loop power required, reducing installation complexity
-
Industrial-grade reliability for continuous operation
Technical Specifications
| Specification | Details |
|---|---|
| Model Number | IC670ALG620 |
| Input Channels | 4 independent RTD inputs (3-wire or 4-wire) |
| Supported RTD Types | Platinum, Nickel, Nickel/Iron, Copper |
| Resistance Ranges | 0–500 Ω, 0–3000 Ω (selectable) |
| Measurement Units | Ω, °C, °F (tenths resolution) |
| Scan Time | 210 ms (60 Hz), 230 ms (50 Hz) |
| Digital Resolution | 15-bit plus sign |
| Maximum Lead Resistance | 5 Ω per lead |
| Normal Mode Rejection | 60 dB at 50/60 Hz, 100% span |
| Temperature Sensitivity | ±0.004% of reading, ±1.5 mV/°C referred to input (0–60°C) |
| Fault Detection | Open RTD, short, underrange, overrange, high/low alarms |
| Power Requirements | Draws up to 190 mA from BIU supply, no loop power needed |
| Dimensions | 120 × 50 × 100 mm |
| Weight | 0.45 kg |
Applications
Ideal for process control systems, distributed control stations, and temperature monitoring in industrial environments where precise RTD measurements are required. It integrates seamlessly with GE Field Control systems for automated and reliable operation.
FAQ
Q: Can the module measure multiple RTD types simultaneously?
A: Yes, each channel can be individually configured for Platinum, Nickel, Nickel/Iron, or Copper RTDs.
Q: Is external power required for the RTDs?
A: No, the module does not require loop power; it draws power directly from the Bus Interface Unit.
Q: How is configuration performed?
A: The module is configured via a handheld device connected to the main Bus Interface Unit.
Savybės
Mes priimame didelius užsakymus ir turime minimalią užsakymo kiekį – tik vieną vienetą.
Pagal užklausą galime pateikti visus reikiamus dokumentus, įskaitant kilmės/atitikties sertifikatus ir kitus būtinus eksporto dokumentus.
Sandėlyje esančius daiktus siekiame pristatyti per 1-3 dienas po apmokėjimo patvirtinimo. Daiktai su nurodytu pristatymo terminu bus pristatyti pagal nurodytą grafiką.
Mes priimame 100 % T/T (telegrafinius pervedimus) apmokėjimą prieš išsiuntimą. Prekėms su laukimo terminais reikalinga 30 % avansinė įmoka, likusieji 70 % turi būti sumokėti prieš išsiuntimą. Dėl RMB pervedimų, jei turite agentą Kinijoje, susisiekite su mumis.
Mes siūlome standartinę vienerių metų garantiją visiems naujiems ir originaliems daiktams. Jei jums reikalinga pratęsta garantija, prašome susisiekti su mumis dėl papildomų kainos detalių.
Jūsų pasitenkinimas mums svarbus. Jei reikia grąžinti prekę, tai turi būti padaryta per 30 dienų nuo užsakymo datos. Produktas turi būti nenaudotas, neuždarytas ir originalioje pakuotėje su visais priedais. Pinigų grąžinimas atliekamas per 5-7 darbo dienas nuo grąžintos prekės gavimo. Atkreipkite dėmesį, kad siuntimo ir susijusios išlaidos negrąžinamos.