{"product_id":"ge-mark-v-ds215tcqag1bzz01a-tcqa-analog-i-o-board","title":"GE Mark V DS215TCQAG1BZZ01A TCQA Analog I\/O Board","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDS215TCQAG1BZZ01A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a TCQA series analog input\/output board designed for GE Mark V Speedtronic turbine control systems. Engineered for gas and steam turbine applications, this board acquires, conditions, and transmits critical process signals to the control logic, ensuring reliable and accurate operation. Integrated firmware enhances compatibility and operational stability within Mark V systems.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Functions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAnalog Signal Conditioning\u003c\/strong\u003e: Converts raw sensor signals, including temperature, pressure, flow, and vibration, into usable data for the control system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eData Acquisition\u003c\/strong\u003e: Provides real-time process values directly to the Mark V control logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFirmware Integration\u003c\/strong\u003e: Ensures seamless operation and compatibility with turbine control systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Role\u003c\/strong\u003e: Typically installed in R\/S\/T cores of the Mark V system to manage analog I\/O signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGE (General Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eMark V Speedtronic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel \/ Part Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDS215TCQAG1BZZ01A\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Acronym\u003c\/td\u003e\n\u003ctd\u003eTCQA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eAnalog Input\/Output Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e262 × 185 × 39 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.39 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePCB Coating\u003c\/td\u003e\n\u003ctd\u003eStandard Coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Revision\u003c\/td\u003e\n\u003ctd\u003eRev 1 B \/ Z\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstruction Manual\u003c\/td\u003e\n\u003ctd\u003eGEH-6195\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eGas and steam turbine control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMonitoring process parameters such as temperature, pressure, flow, and vibration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTurbine protection and efficiency optimization\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrated within Mark V R\/S\/T core modules for analog I\/O management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Can this board replace older TCQA models?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA1:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDS215TCQAG1BZZ01A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis compatible with previous TCQA boards in Mark V systems. Verify functional revision to ensure full compatibility.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Is the board firmware included?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA2:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes, the board comes preloaded with firmware for signal conditioning and data acquisition, ensuring seamless integration with Mark V systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What types of analog signals can be connected?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA3:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIt supports temperature, pressure, flow, vibration, and other process analog signals.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":42010575732826,"sku":"DS215TCQAG1BZZ01A","price":157.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/DS215TCQAG1BZZO1A.jpg?v=1750750446","url":"https:\/\/www.plcmasters.com\/lt\/products\/ge-mark-v-ds215tcqag1bzz01a-tcqa-analog-i-o-board","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}