{"product_id":"schneider-bmxart0414-analog-isolated-low-level-input-module","title":"Schneider BMXART0414 Analog Isolated Low-Level Input Module","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSchneider Electric BMXART0414\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-precision, isolated analog input module for Modicon X80 systems. It handles low-level voltage, resistance, and temperature sensor signals. The module supports demanding industrial environments and ensures reliable measurements. Its 4-channel design allows flexible integration with Modicon M340 and M580 systems. It features robust isolation between channels and high measurement accuracy.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBMXART0414\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eType:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAnalog Isolated Low-Level Input Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeries:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eModicon X80\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChannels:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4 analog inputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Types:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eVoltage: ±40 mV, ±80 mV, ±160 mV, ±320 mV, ±640 mV, ±1.28 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResistance: 400 Ω and 4000 Ω (2-, 3-, and 4-wire)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTemperature Sensors: Cu10, Pt100, Pt1000 (IEC and UL\/JIS standards)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConversion Resolution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e16-bit triangular integration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Overload:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e±7.5 V across all voltage ranges\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommon Mode Rejection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e120 dB at 50\/60 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDifferential Mode Rejection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e60 dB at 50\/60 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Drift:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e25–30 ppm\/°C depending on input type\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCold Junction Compensation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eExternal Pt100 probe support for thermocouples\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurement Accuracy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e±0.05–5 °C depending on sensor type and range\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation Voltage:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1400 V DC between channels and bus\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e750 V DC between channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e750 V DC between channels and ground\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLED Indicators:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 green LED for module operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 green LED per channel for diagnostics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e2 red LEDs for errors and I\/O faults\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIP20, operating temperature 0–60 °C, storage -40–85 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVibration \u0026amp; Shock Resistance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3 gn vibration, 30 gn shock\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNet Weight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.135 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Consumption:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e150 mA at 3.3 V DC, 40 mA at 24 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":42432464486490,"sku":"BMXART0414","price":182.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/BMXART04142.jpg?v=1760342389","url":"https:\/\/www.plcmasters.com\/lt\/products\/schneider-bmxart0414-analog-isolated-low-level-input-module","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}