{"product_id":"yokogawa-nftr8s-10-rtd-input-module","title":"Yokogawa NFTR8S-10 RTD Input Module","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa NFTR8S‑10\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-precision 8-channel RTD input module designed for the FCN (Field Control Node) autonomous controller platform. It delivers stable and accurate temperature measurements using industrial-grade RTDs such as Pt100 and JPt100. Each input channel is fully isolated to ensure signal integrity in electrically noisy and harsh industrial environments. This module is ideal for process industries requiring precise temperature monitoring and control.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eInput Characteristics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eNumber of Channels: 8 fully isolated RTD inputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupported RTD Types: Pt100 (IEC 60751), JPt100 (JIS C1604)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnection: 3-wire RTD configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMeasurement Range: −200 °C to +650 °C (application dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInput Resolution: High-resolution A\/D conversion for accurate readings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAccuracy: ±0.1% typical, stable over industrial temperature ranges\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation \u0026amp; Protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eChannel-to-Channel Isolation: Ensures independent operation without interference\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eChannel-to-System Isolation: Protects against system-level noise\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eElectrical Protection: Safeguards against wiring errors, EMI, and industrial interference\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eUpdate Rate: Approx. 1 second (controller dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNoise Immunity: Designed for high-EMI industrial environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLong-Term Stability: Minimal drift over extended operation periods\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eForm Factor: Plug-in FCN I\/O module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDimensions: 130 × 107.5 × 32.8 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: 0.3 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMounting: Compatible with FCN I\/O baseplate\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: −20 °C to +70 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage Temperature: −20 °C to +70 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRelative Humidity: 5–95% non-condensing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVibration Resistance: Industrial-grade\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eContinuous temperature monitoring in chemical, oil \u0026amp; gas, power, and water treatment plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRTD-based control loops for process automation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafety-critical temperature measurements in industrial systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegration with SCADA and autonomous FCN controllers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this module support 2-wire RTDs?\u003c\/strong\u003e\u003cbr\u003eA: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNFTR8S‑10\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis optimized for 3-wire RTD inputs; 2-wire configuration may reduce measurement accuracy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does it differ from the NFTR4S module?\u003c\/strong\u003e\u003cbr\u003eA: NFTR4S offers 4 channels versus 8 on NFTR8S‑10. Both provide high isolation and accuracy, but NFTR8S‑10 is suited for higher channel density applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the module hot-swappable?\u003c\/strong\u003e\u003cbr\u003eA: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNFTR8S‑10\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed for plug-in installation but should be powered down during replacement to ensure system safety.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":42884496982106,"sku":"NFTR8S-10","price":264.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/NFSBT022.jpg?v=1770269805","url":"https:\/\/www.plcmasters.com\/lt\/products\/yokogawa-nftr8s-10-rtd-input-module","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}