Overview
The EPRO CON021/915-080 is a high-precision eddy current signal converter designed for rotating machinery monitoring. It accurately measures shaft displacement, position, eccentricity, and speed/key signals. It is widely used in steam, gas, and hydro turbines, as well as compressors, pumps, and fans.
This model works with multiple eddy current probes, including PR6422, PR6423, PR6424, PR6425 (requires extended range converter), PR6426, and PR6453. It converts sensor signals into standardized analog outputs for integration with monitoring and protection systems. The CON021/915-080 is optimized for MMS 6000 and IMR 6000 rack systems and supports hot-swappable installation, ensuring continuous operation of critical rotating equipment.
Technical Specifications
| Parameter | Specification |
|---|---|
| Function | Eddy current signal converter for shaft displacement, position, eccentricity, and speed/key monitoring |
| Frequency Range | 0–20 kHz (-3 dB) |
| Rise Time | <15 μs for accurate dynamic measurement |
| Compatible Sensors | PR6422, PR6423, PR6424, PR6425 (extended range), PR6426, PR6453 |
| Supply Voltage | -23V to -32V (Output -4V to -20V) -21V to -32V (Output -2V to -18V) |
| Output Signal | Standardized analog output (depending on configuration) |
| Operating Temperature | -30°C to +100°C (-22°F to +212°F) |
| Shock & Vibration | 5g @ 60 Hz @ 25°C |
| Protection Class | IP20 |
| Housing Material | LMgSi 0.5 F22 Aluminum Alloy |
| Weight | 120 g |
| Mounting | Rack-based installation (MMS 6000 / IMR 6000 compatible) |
| Connections | Self-locking LEMO plug or screw terminal options |
| Integration | Hot-swappable for rack systems |
Applications
-
Steam, gas, and hydro turbine monitoring
-
Rotating machinery: compressors, pumps, and fans
-
Process control and protection systems
FAQ
Q1: Which sensors are compatible with CON021/915-080?
A1: Compatible with PR6422, PR6423, PR6424, PR6425 (extended range), PR6426, and PR6453.
Q2: Can this module be replaced while running?
A2: Yes, it supports hot-swappable installation in MMS 6000 and IMR 6000 racks.
Q3: What is the typical measurement range?
A3: Using PR6425 extended range, ±8.0 mm with ≤3% linearity error.
Q4: What is the operating temperature range?
A4: -30°C to +100°C, suitable for most industrial rotating machinery environments.
Ciri-ciri
Kami mengalu-alukan pesanan pukal dan mempunyai kuantiti pesanan minimum hanya satu unit.
Atas permintaan, kami boleh menyediakan semua dokumentasi yang diperlukan, termasuk Sijil Asal/Kepatuhan dan dokumen eksport lain yang diperlukan.
Untuk barang dalam stok, kami berhasrat untuk menghantar dalam masa 1-3 hari selepas pengesahan pembayaran. Barang dengan masa utama yang ditetapkan akan dihantar mengikut jadual yang dinyatakan.
Kami menerima pembayaran 100% T/T (Pemindahan Telegraf) sebelum penghantaran. Untuk barang dengan masa menunggu, deposit 30% diperlukan terlebih dahulu, dengan baki 70% perlu dibayar sebelum penghantaran. Untuk pemindahan RMB, sila hubungi kami jika anda mempunyai ejen di China.
Kami menawarkan jaminan standard satu tahun untuk semua barang baru dan asli. Jika anda memerlukan jaminan lanjutan, sila hubungi kami untuk maklumat kos tambahan.
Kepuasan anda penting bagi kami. Jika anda perlu memulangkan barang, ia mesti dilakukan dalam masa 30 hari dari tarikh pesanan. Produk mesti tidak digunakan, tidak dibuka, dan dalam pembungkusan asal dengan semua aksesori disertakan. Bayaran balik diproses dalam masa 5-7 hari bekerja selepas kami menerima barang yang dipulangkan. Sila ambil perhatian bahawa caj penghantaran dan berkaitan tidak boleh dikembalikan.