Penerangan
Overview
The IC670ALG620 module from GE Fanuc is a high-precision RTD input interface designed for Field Control systems. It supports four independent channels and is compatible with both 3-wire and 4-wire RTD sensors, including Platinum, Nickel, Nickel/Iron, and Copper types. The module converts resistance measurements into accurate temperature data for process monitoring, control applications, and industrial automation systems.
Key Features
-
Four fully isolated RTD input channels for flexible sensor integration
-
Supports 3-wire and 4-wire RTD configurations
-
Configurable measurement ranges: 0–500 Ω or 0–3000 Ω
-
Outputs in resistance (Ω), Celsius (°C), or Fahrenheit (°F) with tenths resolution
-
Built-in diagnostics for open-wire, short-circuit, overrange/underrange, and high/low alarms
-
No external loop power required, reducing installation complexity
-
Industrial-grade reliability for continuous operation
Technical Specifications
| Specification | Details |
|---|---|
| Model Number | IC670ALG620 |
| Input Channels | 4 independent RTD inputs (3-wire or 4-wire) |
| Supported RTD Types | Platinum, Nickel, Nickel/Iron, Copper |
| Resistance Ranges | 0–500 Ω, 0–3000 Ω (selectable) |
| Measurement Units | Ω, °C, °F (tenths resolution) |
| Scan Time | 210 ms (60 Hz), 230 ms (50 Hz) |
| Digital Resolution | 15-bit plus sign |
| Maximum Lead Resistance | 5 Ω per lead |
| Normal Mode Rejection | 60 dB at 50/60 Hz, 100% span |
| Temperature Sensitivity | ±0.004% of reading, ±1.5 mV/°C referred to input (0–60°C) |
| Fault Detection | Open RTD, short, underrange, overrange, high/low alarms |
| Power Requirements | Draws up to 190 mA from BIU supply, no loop power needed |
| Dimensions | 120 × 50 × 100 mm |
| Weight | 0.45 kg |
Applications
Ideal for process control systems, distributed control stations, and temperature monitoring in industrial environments where precise RTD measurements are required. It integrates seamlessly with GE Field Control systems for automated and reliable operation.
FAQ
Q: Can the module measure multiple RTD types simultaneously?
A: Yes, each channel can be individually configured for Platinum, Nickel, Nickel/Iron, or Copper RTDs.
Q: Is external power required for the RTDs?
A: No, the module does not require loop power; it draws power directly from the Bus Interface Unit.
Q: How is configuration performed?
A: The module is configured via a handheld device connected to the main Bus Interface Unit.
Ciri-ciri
Kami mengalu-alukan pesanan pukal dan mempunyai kuantiti pesanan minimum hanya satu unit.
Atas permintaan, kami boleh menyediakan semua dokumentasi yang diperlukan, termasuk Sijil Asal/Kepatuhan dan dokumen eksport lain yang diperlukan.
Untuk barang dalam stok, kami berhasrat untuk menghantar dalam masa 1-3 hari selepas pengesahan pembayaran. Barang dengan masa utama yang ditetapkan akan dihantar mengikut jadual yang dinyatakan.
Kami menerima pembayaran 100% T/T (Pemindahan Telegraf) sebelum penghantaran. Untuk barang dengan masa menunggu, deposit 30% diperlukan terlebih dahulu, dengan baki 70% perlu dibayar sebelum penghantaran. Untuk pemindahan RMB, sila hubungi kami jika anda mempunyai ejen di China.
Kami menawarkan jaminan standard satu tahun untuk semua barang baru dan asli. Jika anda memerlukan jaminan lanjutan, sila hubungi kami untuk maklumat kos tambahan.
Kepuasan anda penting bagi kami. Jika anda perlu memulangkan barang, ia mesti dilakukan dalam masa 30 hari dari tarikh pesanan. Produk mesti tidak digunakan, tidak dibuka, dan dalam pembungkusan asal dengan semua aksesori disertakan. Bayaran balik diproses dalam masa 5-7 hari bekerja selepas kami menerima barang yang dipulangkan. Sila ambil perhatian bahawa caj penghantaran dan berkaitan tidak boleh dikembalikan.