Penerangan
Overview
The Honeywell FS-SICC-1011/L3 is a high-performance shielded interconnection cable designed for Safety Instrumented Systems (SIS), Distributed Control Systems (DCS), and fire alarm networks. Engineered for reliability, this cable ensures consistent signal integrity, electrical isolation, and robust protection in demanding industrial environments.
Technical Specifications
| Specification | Details |
|---|---|
| Cable Type | Shielded twisted-pair interconnection |
| Conductors | 9 copper conductors |
| Wire Gauge | 28 AWG |
| Shield | Braided for EMI/RFI protection |
| Voltage Rating | Up to 300 V |
| Conductor Resistance | 5.2 Ω/km at 20 °C |
| Insulation Resistance | ≥ 500 MΩ/km |
| Jacket Material | Flame-retardant PVC |
| Connector Type | D-sub connectors at each end |
| Standard Length | 3 m (9.8 ft), custom lengths available |
| Operating Temperature | -20 °C to +60 °C |
| Storage Temperature | -40 °C to +80 °C |
| Compliance | Honeywell SIS/DCS standards, NFPA fire safety requirements |
| Weight | 0.2 kg |
Key Features
-
Shielded design minimizes electromagnetic interference.
-
Flame-retardant jacket provides enhanced safety for fire alarm applications.
-
Electrical isolation ensures safe testing and commissioning of live loops.
-
Durable construction resists oils, chemicals, and mechanical stress.
-
Compatible with Honeywell controllers, I/O modules, and Field Termination Assemblies (FTA).
Applications
-
Safety Instrumented Systems (SIS): Reliable connection between safety controllers and field devices.
-
Distributed Control Systems (DCS): Stable interconnection for process automation networks.
-
Fire alarm systems: NFPA-compliant interconnection between panels and sensors.
-
Industrial automation: Oil & gas, chemical plants, and manufacturing environments requiring shielded cabling.
FAQ
Q: Can this cable be customized in length?
A: Yes, lengths beyond the standard 3 m can be configured upon request.
Q: Is the cable suitable for high-voltage applications?
A: It is rated up to 300 V; higher voltage applications require alternative specification cables.
Q: How does this differ from FS-SICC-1010 series cables?
A: The FS-SICC-1011/L3 provides enhanced EMI shielding and a flame-retardant jacket, making it more suitable for SIS and fire alarm systems.
Ciri-ciri
Kami mengalu-alukan pesanan pukal dan mempunyai kuantiti pesanan minimum hanya satu unit.
Atas permintaan, kami boleh menyediakan semua dokumentasi yang diperlukan, termasuk Sijil Asal/Kepatuhan dan dokumen eksport lain yang diperlukan.
Untuk barang dalam stok, kami berhasrat untuk menghantar dalam masa 1-3 hari selepas pengesahan pembayaran. Barang dengan masa utama yang ditetapkan akan dihantar mengikut jadual yang dinyatakan.
Kami menerima pembayaran 100% T/T (Pemindahan Telegraf) sebelum penghantaran. Untuk barang dengan masa menunggu, deposit 30% diperlukan terlebih dahulu, dengan baki 70% perlu dibayar sebelum penghantaran. Untuk pemindahan RMB, sila hubungi kami jika anda mempunyai ejen di China.
Kami menawarkan jaminan standard satu tahun untuk semua barang baru dan asli. Jika anda memerlukan jaminan lanjutan, sila hubungi kami untuk maklumat kos tambahan.
Kepuasan anda penting bagi kami. Jika anda perlu memulangkan barang, ia mesti dilakukan dalam masa 30 hari dari tarikh pesanan. Produk mesti tidak digunakan, tidak dibuka, dan dalam pembungkusan asal dengan semua aksesori disertakan. Bayaran balik diproses dalam masa 5-7 hari bekerja selepas kami menerima barang yang dipulangkan. Sila ambil perhatian bahawa caj penghantaran dan berkaitan tidak boleh dikembalikan.