{"product_id":"1763-mm1-allen-bradley-memory-module","title":"1763-MM1 Allen-Bradley Memory Module","description":"\u003ch2\u003eAllen-Bradley 1763-MM1 Memory Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1763-MM1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e1763-MM1\u003c\/strong\u003e Memory Module, operates as a dedicated hardware component for non-volatile program storage and data backup within MicroLogix 1100 controller systems. The plug-in EEPROM module provides removable memory expansion with 128 KB capacity for application transfer and recovery functions.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1763-MM1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.02 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSupplied by MicroLogix 1100 controller interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eMemory Expansion Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eMicroLogix 1100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Type\u003c\/td\u003e\n\u003ctd\u003eNon-Volatile EEPROM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Capacity\u003c\/td\u003e\n\u003ctd\u003e128 KB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Method\u003c\/td\u003e\n\u003ctd\u003ePlug-in Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eMicroLogix 1100 Controllers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5-95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Functions\u003c\/td\u003e\n\u003ctd\u003eWrite Protection, Program Comparison\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecovery Function\u003c\/td\u003e\n\u003ctd\u003eAuto-Recovery After Faults\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eUL, CSA, CE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFirmware Flash Compatibility and Controller Memory Handling\u003c\/h3\u003e\n\u003cp\u003eThe 1763-MM1 provides MicroLogix 1100 I\/O and application data storage expansion through a removable EEPROM interface. The module supports firmware flash compatibility within the supported controller platform and maintains stored program data without continuous power.\u003c\/p\u003e\n\u003cp\u003eThe memory module allows application transfer between compatible controllers and supports program backup operations. Write protection functions control modification of stored data, while program comparison functions support verification between controller memory and external storage.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: What memory capacity is available on the Allen-Bradley 1763-MM1?\u003cbr\u003eA: The 1763-MM1 provides 128 KB of non-volatile EEPROM memory for MicroLogix 1100 controller applications.\u003c\/p\u003e\n\u003cp\u003eQ: Can the 1763-MM1 be removed while the controller is powered?\u003cbr\u003eA: The module supports insertion and removal under power when used with compatible MicroLogix 1100 controllers according to installation requirements.\u003c\/p\u003e\n\u003cp\u003eQ: What type of data can be stored on the 1763-MM1?\u003cbr\u003eA: The module stores user programs and data for backup, transport, and recovery operations.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the 1763-MM1 directly into the designated memory module interface of a compatible MicroLogix 1100 controller. Verify controller compatibility before inserting the module.\u003c\/p\u003e\n\u003cp\u003eUse standard ESD handling procedures during installation. Avoid contact with connector pins and protect the module from conductive contamination.\u003c\/p\u003e\n\u003cp\u003eFor control cabinet installations, maintain proper grounding practices and route memory-related control wiring away from high-voltage sources and high-current switching conductors.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43655772176474,"sku":"1763-MM1","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/1763-MM12.jpg?v=1784001516","url":"https:\/\/www.plcmasters.com\/products\/1763-mm1-allen-bradley-memory-module","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}