{"product_id":"1766-l32awa-allen-bradley-micrologix-controller","title":"1766-L32AWA Allen Bradley MicroLogix Controller","description":"\u003ch2\u003eAllen Bradley 1766-L32AWA MicroLogix 1400 Programmable Controller\u003c\/h2\u003e\n\u003cp\u003eConfigured for integrated machine control execution in MicroLogix 1400 controller platforms, the \u003cstrong\u003eAllen Bradley 1766-L32AWA\u003c\/strong\u003e (\u003cstrong\u003e1766-L32AWA\u003c\/strong\u003e Programmable Controller) provides direct physical\/electrical execution through AC input processing, relay output switching, and industrial communication interfaces.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1766-L32AWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.45 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eProgrammable Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eMicroLogix 1400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e100-240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Frequency\u003c\/td\u003e\n\u003ctd\u003e47-63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e20 x 120 VAC inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Outputs\u003c\/td\u003e\n\u003ctd\u003e12 relay contact outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003e20 KB user memory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003eLCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003e1 isolated RS-232\/RS-485 combo port, 1 Ethernet\/IP port, 1 non-isolated RS-232 port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Type\u003c\/td\u003e\n\u003ctd\u003eOpen-style enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEtherNet\/IP and I\/O Architecture\u003c\/h3\u003e\n\u003cp\u003eThe 1766-L32AWA controller integrates MicroLogix 1400 I\/O processing with local digital and analog signal handling. The controller provides 20 AC digital input channels and 12 relay outputs for discrete control circuits. The embedded Ethernet\/IP interface supports controller communication within industrial Ethernet networks, while the RS-232\/RS-485 communication ports provide serial device connectivity.\u003c\/p\u003e\n\u003cp\u003eThe MicroLogix 1400 architecture supports I\/O density scaling through integrated channels and expansion capability. Controller firmware compatibility and application transfer procedures are managed through the MicroLogix programming environment.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: What type of output switching is supported by the 1766-L32AWA?\u003cbr\u003eA: The controller provides 12 relay contact outputs for switching external control circuits.\u003c\/p\u003e\n\u003cp\u003eQ: What communication interfaces are available on this controller?\u003cbr\u003eA: The module includes one isolated RS-232\/RS-485 combo port, one Ethernet\/IP port, and one non-isolated RS-232 port with D-sub connector.\u003c\/p\u003e\n\u003cp\u003eQ: What power supply input is required for the controller?\u003cbr\u003eA: The 1766-L32AWA operates from a 100-240 VAC power supply input with a frequency range of 47-63 Hz.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the controller inside an appropriate electrical enclosure according to industrial control panel practices. Verify the 100-240 VAC supply wiring before energizing the unit.\u003c\/p\u003e\n\u003cp\u003eRoute communication cables separately from high-voltage power conductors to reduce electromagnetic interference. Use shielded communication wiring where required by the network installation environment, and terminate cable shields according to the grounding method defined for the control system.\u003c\/p\u003e\n\u003cp\u003eConfirm terminal assignments for AC inputs, relay outputs, and communication interfaces before field connection. Maintain suitable airflow clearance around the controller and avoid installation locations with excessive vibration, contamination, or conductive dust.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43661044219994,"sku":"1766-L32AWA","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/1766-L32AWA2.jpg?v=1784088144","url":"https:\/\/www.plcmasters.com\/products\/1766-l32awa-allen-bradley-micrologix-controller","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}