{"product_id":"1783-etapk-allen-bradley-ethernet-ip-tap-kit","title":"1783-ETAPK Allen-Bradley EtherNet\/IP Tap Kit","description":"\u003ch2\u003eAllen-Bradley 1783-ETAPK EtherNet\/IP Tap Kit\u003c\/h2\u003e\n\u003cp\u003eConfigured for EtherNet\/IP traffic monitoring in industrial Ethernet networks, the \u003cstrong\u003eAllen-Bradley 1783-ETAPK\u003c\/strong\u003e (\u003cstrong\u003e1783-ETAPK\u003c\/strong\u003e EtherNet\/IP Tap Kit) provides passive signal access through three copper RJ45 ports for communication diagnostics and network analysis without interrupting controller-to-device data exchange.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Element\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1783\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley Stratix industrial Ethernet product family\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eETAPK\u003c\/td\u003e\n\u003ctd\u003eEtherNet\/IP Tap Kit configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Function\u003c\/td\u003e\n\u003ctd\u003ePassive Ethernet traffic monitoring and diagnostic access\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Interface\u003c\/td\u003e\n\u003ctd\u003eThree copper RJ45 10\/100BASE-TX ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1783-ETAPK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.01 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e118 x 87 x 58 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-25 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eEtherNet\/IP Tap Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort Configuration\u003c\/td\u003e\n\u003ctd\u003e3 x RJ45 10\/100BASE-TX copper ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocol Support\u003c\/td\u003e\n\u003ctd\u003eEtherNet\/IP, CIP, TCP\/IP, UDP\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Method\u003c\/td\u003e\n\u003ctd\u003eStore-and-forward\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal (20.4 to 27.6 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003eMaximum 125 mA at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e30 V continuous; type tested at 1250 VDC for 60 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eOpen-style, IP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Method\u003c\/td\u003e\n\u003ctd\u003eDIN rail mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eUL, cUL, CE, ATEX Zone 2, IECEx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEtherNet\/IP Deterministic Network Diagnostics\u003c\/h3\u003e\n\u003cp\u003eThe 1783-ETAPK operates within Allen-Bradley EtherNet\/IP deterministic networks by providing passive access to Ethernet communication frames. The tap kit supports controller and device communication analysis through mirrored traffic monitoring without modifying the network data path.\u003c\/p\u003e\n\u003cp\u003eThe three-port copper interface supports 10\/100BASE-TX communication and EtherNet\/IP protocol traffic including CIP messaging. The module architecture supports firmware compatibility requirements within Stratix Ethernet infrastructure and allows integration with industrial network diagnostic tools.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 1783-ETAPK interrupt normal EtherNet\/IP communication during monitoring?\u003cbr\u003eA: The EtherNet\/IP Tap Kit provides passive monitoring access and is designed to observe network traffic without disrupting the primary communication path.\u003c\/p\u003e\n\u003cp\u003eQ: What type of Ethernet connection is supported by the module?\u003cbr\u003eA: The module uses three copper RJ45 ports supporting 10\/100BASE-TX Ethernet connections.\u003c\/p\u003e\n\u003cp\u003eQ: What power supply range is required for operation?\u003cbr\u003eA: The module requires a 24 VDC supply with an operating range of 20.4 to 27.6 VDC.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the 1783-ETAPK on a DIN rail mounting surface inside an enclosure suitable for the IP20 open-style construction. Use Category 5e or higher Ethernet cabling following applicable TIA\/EIA wiring standards.\u003c\/p\u003e\n\u003cp\u003eRoute Ethernet communication cables separately from high-voltage power wiring to minimize electromagnetic interference. Maintain proper shield termination practices where shielded cables are applied.\u003c\/p\u003e\n\u003cp\u003eVerify 24 VDC power polarity before connection. Tighten power connector terminals according to the specified installation torque requirement. Confirm link status and traffic visibility through the connected diagnostic equipment after commissioning.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43716018634842,"sku":"1783-ETAPK","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/1783-ETAPK2.jpg?v=1784788595","url":"https:\/\/www.plcmasters.com\/products\/1783-etapk-allen-bradley-ethernet-ip-tap-kit","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}