Skip to content
AB SST-PB3-VME-1 PROFIBUS VMEbus Communication Interface Card

AB SST-PB3-VME-1 PROFIBUS VMEbus Communication Interface Card

  • 16 In stock
  • Manufacturer: AMPHENOL

  • Product No.: SST-PB3-VME-1

  • Condition: In stock

  • Product Type: PROFIBUS VMEbus Communication Interface Card

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 458g

  • Shipping port: Xiamen

  • Warranty: 12 months

{"id":43969176305754,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"SST-PB3-VME-1","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"AB SST-PB3-VME-1 PROFIBUS VMEbus Communication Interface Card","public_title":null,"options":["Default Title"],"price":12300,"weight":458,"compare_at_price":32000,"inventory_management":"shopify","barcode":"USA","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}

Description

AB SST-PB3-VME-1 PROFIBUS VMEbus Communication Interface Card

Configured for PROFIBUS DP data exchange in VMEbus systems, the AB SST-PB3-VME-1 (SST-PB3-VME-1 PROFIBUS Communication Interface Card) provides one-channel RS-485 network communication with onboard protocol processing.

Hardware Specifications

Parameter Specification
Model SST-PB3-VME-1
Brand AB / SST / Woodhead
Origin USA / Manufacturer origin not explicitly specified
Weight 1.01 lb
Dimensions VMEbus single-slot format; 6U / 3U depending on bracket assembly
Operating Temp 0 deg C to +60 deg C
Power Consumption Not specified in supplied data
VMEbus Interface Single-slot VMEbus
PROFIBUS Interface 1 x DB-9 female, RS-485
PROFIBUS Protocol PROFIBUS DP-V0, DP-V1
Operating Modes Master Class 1, Master Class 2, Slave
Number of Channels 1
Baud Rate 9.6 kbps to 12 Mbps
Baud Detection Automatic baud-rate detection
Onboard Processor Embedded communications processor
Host Data Interface Dual-port RAM / shared memory
Diagnostic Indicators Module status, network status, communication activity
Storage Temp -40 deg C to +85 deg C
Relative Humidity 5% to 95%, non-condensing

PROFIBUS DP Communication Architecture

The SST-PB3-VME-1 provides a single PROFIBUS DP channel through an RS-485 physical interface. The card supports DP-V0 and DP-V1 operation, including Master Class 1, Master Class 2, and Slave functions.

An onboard communications processor handles PROFIBUS protocol execution independently of the VME host processor. Dual-port RAM provides the host-side data exchange mechanism between application software and the communication processor.

The interface supports network rates from 9.6 kbps through 12 Mbps with automatic baud-rate detection. Diagnostic LEDs provide local indication of module status, PROFIBUS network status, and communication activity.

For VME-based control architectures, the card operates as an in-chassis communication interface while the host system accesses process data through the VMEbus memory interface.

Frequently Asked Questions (FAQ)

Q: How many PROFIBUS communication channels does the SST-PB3-VME-1 provide?
A: The supplied specifications identify one PROFIBUS channel using a DB-9 female RS-485 interface.

Q: Does the card require the VME host CPU to execute the PROFIBUS protocol?
A: No. An onboard communications processor performs protocol execution, while dual-port RAM transfers communication data to the VME host.

Q: Which PROFIBUS operating modes are supported?
A: The supplied data specifies PROFIBUS DP-V0 and DP-V1 operation with Master Class 1, Master Class 2, and Slave modes.

Field Installation Guidelines

Install the card in the designated VMEbus slot and verify mechanical engagement before applying system power.

Connect the PROFIBUS network through the specified DB-9 RS-485 interface using appropriate PROFIBUS-rated cabling and connectors.

Maintain separation between PROFIBUS communication wiring and high-current power, motor, and switching circuits to reduce electromagnetic interference.

Terminate and bias the PROFIBUS segment according to the network topology and connector termination requirements. Do not introduce unintended termination at intermediate devices.

Route communication cable shields continuously through compatible connectors and bond shielding according to the cabinet grounding design.

Verify VMEbus seating, connector condition, network polarity, cable shielding, and termination before commissioning communication.

Confirm that the configured PROFIBUS baud rate and master/slave role correspond with the host application and connected field devices.

Features

We welcome bulk orders and have a minimum order quantity of just one unit.

Upon request, we can provide all necessary documentation, including Certificates of Origin/Conformance and other required export documents.

For items in stock, we aim to deliver within 1-3 days after payment confirmation. Items with specified lead times will be delivered according to the quoted schedule.

We accept 100% T/T (Telegraphic Transfer) payment before shipping. For items with lead times, a 30% deposit is required upfront, with the remaining 70% due before shipment. For RMB transfers, please contact us if you have an agent in China.

We offer a standard one-year warranty on all new and original items. If you require an extended warranty, please contact us for additional cost details.

Your satisfaction is important to us. If you need to return an item, it must be done within 30 days of the order date. The product must be unused, unopened, and in its original packaging with all accessories included. Refunds are processed within 5-7 business days after we receive the returned item. Please note that shipping and related charges are non-refundable.

Featured

Complementary products