{"product_id":"abb-3bhl001089p0001-type-8225-conductivity-meter","title":"ABB 3BHL001089P0001 Type 8225 Conductivity Meter","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB 3BHL001089P0001\u003c\/strong\u003e is a precision conductivity meter designed for continuous monitoring of conductive aqueous solutions. Engineered for industrial applications, it delivers reliable measurements in water treatment, chemical processing, and food \u0026amp; beverage production. Its compact, rugged construction allows panel or field installation in harsh environments.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMeasures conductivity across a wide spectrum of solutions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAutomatic and manual temperature compensation (0–100°C)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompact housing suitable for panel or wall mounting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrated outputs for 4–20 mA analog or optional Modbus RTU digital communication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResistant to corrosive fluids and industrial conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurement\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eConductivity Range: 0.1 µS\/cm to 1000 mS\/cm (sensor dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAccuracy: ±0.5% of reading\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTemperature Compensation: 0–100°C (automatic\/manual)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSensor Compatibility: Inductive and contact-type sensors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePower Supply: 24 VDC or 110–230 VAC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOutput Signals: 4–20 mA analog, optional Modbus RTU\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDimensions: 120 × 90 × 60 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: 0.863 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMounting Options: Panel or wall\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: 0–60°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRelative Humidity: 5–95% (non-condensing)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDurability: Chemically resistant and high-temperature tolerant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWater treatment and purification monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFood \u0026amp; beverage quality control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eChemical process monitoring of conductive fluids\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLaboratory analysis for precise conductivity measurement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCan the meter handle high-conductivity industrial fluids?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes, depending on the sensor type, it can measure up to 1000 mS\/cm.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIs it compatible with modern digital control systems?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes, it provides 4–20 mA analog output and optional Modbus RTU communication for seamless integration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAre replacement parts available for older units?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3BHL001089P0001\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ereplaces SW-6110024 and HL001089P0001. The new replacement unit is 3BHB040253R0001.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":42999553491034,"sku":"3BHL001089P0001","price":258.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/3BHL001089P00012.jpg?v=1772516434","url":"https:\/\/www.plcmasters.com\/products\/abb-3bhl001089p0001-type-8225-conductivity-meter","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}