{"product_id":"allen-bradley-100-e190e-iec-contactor","title":"Allen-Bradley 100-E190E IEC Contactor","description":"\u003ch1\u003eAllen-Bradley 100-E190E IEC Contactor\u003c\/h1\u003e\n\u003cp\u003eConfigured for high-current motor switching and power circuit interruption in Allen-Bradley motor control assemblies, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 100-E190E\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e100-E190E\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIEC contactor) provides direct electrical execution through electronically controlled AC\/DC coil operation and three-pole load switching architecture.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e100-E190E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eBulletin 100-E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eIEC contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eNot specified in supplied documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePole Configuration\u003c\/td\u003e\n\u003ctd\u003e3-pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary Contacts\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Type\u003c\/td\u003e\n\u003ctd\u003eElectronic wide-range AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage Range\u003c\/td\u003e\n\u003ctd\u003e100...250 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operational Current AC-3\u003c\/td\u003e\n\u003ctd\u003e190 A at 415 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operational Current AC-1\u003c\/td\u003e\n\u003ctd\u003e275 A at 690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operational Current AC-3 at 1 kV\u003c\/td\u003e\n\u003ctd\u003e85 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Power Rating\u003c\/td\u003e\n\u003ctd\u003e90 kW at 415 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Power Rating\u003c\/td\u003e\n\u003ctd\u003e132 kW at 690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Power Rating AC-3 at 1 kV\u003c\/td\u003e\n\u003ctd\u003e110 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Voltage\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Suppression\u003c\/td\u003e\n\u003ctd\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eIECEx, CE, UL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLifecycle Status\u003c\/td\u003e\n\u003ctd\u003eActive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eNot specified in supplied documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eNot specified in supplied documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e60 deg C maximum reference for AC-3 current rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eLow coil power consumption design; exact value not specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFirmware and Coil Control Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe 100-E190E utilizes an electronic wide-range AC\/DC coil structure intended to simplify control voltage integration across industrial automation panels. Internal electronic regulation permits operation from 100...250 V AC\/DC without mechanical coil replacement.\u003c\/p\u003e\n\u003cp\u003eIntegrated surge suppression circuitry reduces transient propagation generated during contactor coil de-energization. This arrangement minimizes conducted voltage disturbances entering adjacent PLC I\/O channels, relay interfaces, or distributed control circuits.\u003c\/p\u003e\n\u003cp\u003eThe contactor architecture supports integration into deterministic industrial control networks through standard auxiliary contact feedback circuits connected to PLC digital input monitoring systems.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the 100-E190E be installed inside enclosed motor control cabinets without forced cooling?\u003c\/strong\u003e\u003cbr\u003eA: Cabinet thermal conditions must remain within the operating limits of the connected equipment. Additional ventilation may be required when the contactor operates continuously near maximum AC-3 current ratings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the electronic coil require polarity control on DC supply inputs?\u003c\/strong\u003e\u003cbr\u003eA: The supplied documentation identifies the coil as a wide-range electronic AC\/DC type. Installation wiring should follow terminal markings provided on the device label or manufacturer wiring diagram.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Are auxiliary contacts mechanically linked to the main contact assembly?\u003c\/strong\u003e\u003cbr\u003eA: The unit includes 1 NO and 1 NC auxiliary contacts intended for status feedback and interlock circuits associated with the main switching mechanism.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the contactor vertically on a rigid panel or approved mounting assembly with sufficient clearance for conductor bending radius and heat dissipation. Torque all power terminals according to manufacturer installation procedures to prevent thermal rise at high current loading.\u003c\/p\u003e\n\u003cp\u003eSeparate control wiring from high-current load conductors where possible. Coil control circuits and PLC feedback conductors should not be bundled in parallel with motor feeder cables over extended distances.\u003c\/p\u003e\n\u003cp\u003eVerify phase balance and insulation integrity before energizing the contactor under load. When switching inductive motors or transformers, confirm coordination with upstream overload and short-circuit protective devices.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43416152866906,"sku":"100-E190E","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/100-E190E2.jpg?v=1779773740","url":"https:\/\/www.plcmasters.com\/products\/allen-bradley-100-e190e-iec-contactor","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}